footing size · width
120 in120 in
Drawing notation: 10'0" × 17'0" × 3'2"
Extraction confidence: medium-high.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: pad · 5
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
120 in
Drawing notation: 10'0" × 17'0" × 3'2"
Extraction confidence: medium-high.
204 in
Drawing notation: 10'0" × 17'0" × 3'2"
Extraction confidence: medium-high.
38 in
Drawing notation: 10'0" × 17'0" × 3'2"
Extraction confidence: medium-high.
5 ft
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. Page-left half span from the C5 column axis to the eastern footprint edge.
Drawing notation: 5′0″ + 5′0″
5 ft
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. Page-right half span from the C5 column axis to the western footprint edge.
Drawing notation: 5′0″ + 5′0″
10 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 5′0″ + 5′0″
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Calculated from: footing-5-placement-east-half-span, footing-5-placement-west-half-span, foundation-main-5-footing-widthInches
90 degree
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. The explicit 5′+5′ chain identifies the scheduled 10′ side as X; the scheduled 17′ side is Z. Rotation is modulo 180°. This mapping does not metrically certify the photographed outline.
Drawing notation: 5; 5′0″ + 5′0″; (-7′6″); footing and steel-column centerlines
Drawing notation: 5′0″ + 5′0″
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Calculated from: footing-5-placement-span-x, foundation-main-5-footing-lengthInches
17 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents. Scheduled value retained; not a scaled measurement of the photograph.
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Drawing notation: 5′0″ + 5′0″
Drawing notation: 5; 5′0″ + 5′0″; (-7′6″); footing and steel-column centerlines
Calculated from: foundation-main-5-footing-lengthInches, footing-5-placement-long-axis
3.166667 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Calculated from: foundation-main-5-footing-thicknessInches
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. C5 is explicitly in the C5/C6/C7 header carrying suffix c.
Drawing notation: C5; C6; C7; c
2.75 in
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. Independent reading of c = 2¾″. The general E definition is reused from the prior W409 audit and corroborated by the bottom-note fragment in this key crop.
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Drawing notation: DISTANCES OF C. of G. OF FOOTINGS FROM C.L. OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-5-placement-e-suffix
0 in
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: 5′0″ + 5′0″
Calculated from: footing-5-placement-east-half-span, footing-5-placement-west-half-span
-1 ratio
Nominal footing envelope only; source audit state: checked-master-crop-single-reader. The actual C5/Madison line pair places the footing centerline above the steel-column line; the upright plan's north is down, hence outward/south/−Z. No detached typical-diagram orientation was transferred.
Drawing notation: ℄ FOOTING; ℄ STEEL COLS; separate labeled centerlines continuing through C5
Drawing notation: 5; 5′0″ + 5′0″; (-7′6″); footing and steel-column centerlines
-2.75 in
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: ℄ FOOTING; ℄ STEEL COLS; separate labeled centerlines continuing through C5
Drawing notation: 5; 5′0″ + 5′0″; (-7′6″); footing and steel-column centerlines
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-5-placement-offset-z-sign, footing-5-placement-eccentricity-magnitude
-21 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: 5′0″ + 5′0″
Calculated from: column-5-registered-world-x, footing-5-placement-offset-x
-78.8125 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: ℄ FOOTING; ℄ STEEL COLS; separate labeled centerlines continuing through C5
Drawing notation: C5; C6; C7; c
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: column-5-registered-world-z, footing-5-placement-offset-z
72.75 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-7′6″)
Calculated from: foundation-finished-basement-floor-elevationFeet, foundation-main-5-bottomElevation-inchesRelativeToFinishedBasementFloor
75.916667 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-7′6″)
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Calculated from: footing-5-placement-bottom-el, footing-5-placement-thickness
-26 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: 5′0″ + 5′0″
Calculated from: footing-5-placement-center-x, footing-5-placement-span-x
-16 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: 5′0″ + 5′0″
Calculated from: footing-5-placement-center-x, footing-5-placement-span-x
-87.3125 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Drawing notation: ℄ FOOTING; ℄ STEEL COLS; separate labeled centerlines continuing through C5
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-5-placement-center-z, footing-5-placement-span-z
-70.3125 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: C5; perimeter column bay chain
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Drawing notation: ℄ FOOTING; ℄ STEEL COLS; separate labeled centerlines continuing through C5
Drawing notation: c = 2¾″; OF FOOTINGS FROM ℄ OF MAIN COLUMN ARE GIVEN BY DIMENSION E AND SUFFIX AT TOP OF SCHEDULE.
Calculated from: footing-5-placement-center-z, footing-5-placement-span-z
74.333333 ft
Nominal footing envelope only; source audit state: checked-arithmetic-from-source-linked-parents.
Drawing notation: (-7′6″)
Drawing notation: 5; 10′0″ × 17′0″ × 3′2″; cap 6′0″ × 10′9″ × 2′3[?]″
Calculated from: footing-5-placement-bottom-el, footing-5-placement-top-el
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.