Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1042-assemblyverified · printed
naturalization_clerk_room
NATURALIZATION CLERK ROOM 620Selected visually read source evidence; partial review; assembly-local scope only.
IMG_1042 · Locate on drawing ↗Drawing notation: NATURALIZATION CLERK ROOM 620
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyverified · printed
bankruptcy_clerk_room
BANKRUPTCY CLERK ROOM 616Selected visually read source evidence; partial review; assembly-local scope only.
IMG_1042 · Locate on drawing ↗Drawing notation: BANKRUPTCY CLERK ROOM 616
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyverified · printed
clerk_of_courts_room
CLERK OF COURTS ROOM 615Selected visually read source evidence; partial review; assembly-local scope only.
IMG_1042 · Locate on drawing ↗Drawing notation: CLERK OF COURTS ROOM 615
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyverified · printed
US_marshal_room
U.S. MARSHAL ROOM 603Selected visually read source evidence; partial review; assembly-local scope only.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. MARSHAL ROOM 603
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyverified · printed
US_attorney_room
U.S. ATTORNEY ROOM 621Selected visually read source evidence; partial review; assembly-local scope only.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. ATTORNEY ROOM 621
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyunreviewed · printed
counter_similarity
THIS PANEL SIMILAR TO ALL COUNTERS EXCEPT NAVY [remaining note unresolved]Unresolved source reading; numeric value withheld; partial review.
IMG_1042 · Locate on drawing ↗Drawing notation: THIS PANEL SIMILAR TO ALL COUNTERS EXCEPT NAVY [remaining note unresolved]
Unresolved source reading; numeric value withheld; partial review.
parallel-img1042-assemblyunreviewed · printed
drawer_approval
NOTE: FULL SIZE DRAWINGS OF DRAWERS TO BE APPROVED BY THE ARCHITECTSelected visually read source evidence; partial review; assembly-local scope only. Review correction review-correction-20261013p-parallel-img1042-m007: Attempt 3 same-image native access crop of Naturalization clerk note clearly reads NOTE: ROLLER SHELVES SHOWN ON DRAWINGS TO BE APPROVED BY THE ARCHITECT. The full-size-drawers wording describes the same glyph incorrectly, not a separate revision. Preserve prior ID, null value, raw text unit and verified review until primary records an explicit withdrawal.
IMG_1042 · Locate on drawing ↗Drawing notation: NOTE: FULL SIZE DRAWINGS OF DRAWERS TO BE APPROVED BY THE ARCHITECT
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyverified · printed
plan_counter_depth
30"30 in
Selected visually read source evidence; partial review; assembly-local scope only.
parallel-img1042-assemblyunreviewed · printed
remaining_dimensions_unresolved
[sideways/cropped full office counter schedule; length chains and dimensions unresolved]Numeric value unresolved
Unresolved source reading; numeric value withheld; partial review.
IMG_1042 · Locate on drawing ↗Drawing notation: [sideways/cropped full office counter schedule; length chains and dimensions unresolved]
Unresolved source reading; numeric value withheld; partial review.
parallel-img1042-assemblyverified · printed
lower_rear_counter_depicted_span
14'-9 1/2"177.5 in
Printed lower rear-elevation horizontal dimension. Room/agency caption lies outside crop; source-local witness only, not room extent or installed counter assignment.
IMG_1042 · Locate on drawing ↗Drawing notation: 14'-9 1/2"
Printed lower rear-elevation horizontal dimension. Room/agency caption lies outside crop; source-local witness only, not room extent or installed counter assignment.
parallel-img1042-assemblyverified · printed
lower_rear_gate_panel_dimension
2'-6"30 in
Dimension inside framed gate panel in lower rear view. Endpoints are depicted panel; no clear/rough passage width asserted.
IMG_1042 · Locate on drawing ↗Drawing notation: 2'-6"
Dimension inside framed gate panel in lower rear view. Endpoints are depicted panel; no clear/rough passage width asserted.
parallel-img1042-assemblyverified · printed
panel-similarity-note-resolved
THIS PANEL SIMILAR TO ALL COUNTERS EXCEPT NAVY DIVIDING STILES TO CENTER ON MULLIONS IN REARAdditive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
IMG_1042 · Locate on drawing ↗Drawing notation: THIS PANEL SIMILAR TO ALL COUNTERS EXCEPT NAVY DIVIDING STILES TO CENTER ON MULLIONS IN REAR
Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
parallel-img1042-assemblyverified · printed
office-counter-companion-sheets
SEE SHEETS NOS W243 & W242 FOR SECTIONS, PLANS & SWING GATESAdditive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
IMG_1042 · Locate on drawing ↗Drawing notation: SEE SHEETS NOS W243 & W242 FOR SECTIONS, PLANS & SWING GATES
Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
parallel-img1042-assemblyunreviewed · printed
marshal-room-label-conflict
U.S. MARSHAL ROOM [505?; prior reading 603]Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. MARSHAL ROOM [505?; prior reading 603]
Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
parallel-img1042-assemblyunreviewed · printed
attorney-room-label-conflict
U.S. ATTORNEY ROOM [526?; prior reading 621]Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. ATTORNEY ROOM [526?; prior reading 621]
Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.
parallel-img1042-assemblyverified · printed
marshal_room_label_resolution
U.S. MARSHAL ROOM #505Native master title crop clearly reads 505. Supersedes alternate 603 reading while preserving the older records. Companion IMG_1044 independently labels Marshal 505; no historical revision sequence inferred.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. MARSHAL ROOM #505
Native master title crop clearly reads 505. Supersedes alternate 603 reading while preserving the older records. Companion IMG_1044 independently labels Marshal 505; no historical revision sequence inferred.
Calculated from: detail-20261011g-img1042-3
parallel-img1042-assemblyverified · printed
attorney_room_label_resolution
U.S. ATTORNEY ROOM #526Native master title crop clearly reads 526. Supersedes alternate 621 reading while preserving prior records. Separate printed room label, not a numeric geometric measurement.
IMG_1042 · Locate on drawing ↗Drawing notation: U.S. ATTORNEY ROOM #526
Native master title crop clearly reads 526. Supersedes alternate 621 reading while preserving prior records. Separate printed room label, not a numeric geometric measurement.
Calculated from: detail-20261011g-img1042-4
fixtureenv1013s-img1042-bankruptcy-counterverified · printed
rear_elevation_projected_span
21′-11½″263.5 in
Printed horizontal dimension across Bankruptcy Clerk rear elevation, room #616. Local projected span between drawn overall witnesses; no curved/developed length or world position inferred.
IMG_1042 · Locate on drawing ↗Drawing notation: 21′-11½″
Printed horizontal dimension across Bankruptcy Clerk rear elevation, room #616. Local projected span between drawn overall witnesses; no curved/developed length or world position inferred.
parallel-img1042-assemblyverified · printed
roller_shelf_approval_note
NOTE: ROLLER SHELVES SHOWN ON DRAWINGS TO BE APPROVED BY THE ARCHITECTSeparate transcription of lower Naturalization clerk note, preserving earlier conflicting full-size-drawers transcription; no construction approval inferred.
IMG_1042 · Locate on drawing ↗Drawing notation: NOTE: ROLLER SHELVES SHOWN ON DRAWINGS TO BE APPROVED BY THE ARCHITECT
Separate transcription of lower Naturalization clerk note, preserving earlier conflicting full-size-drawers transcription; no construction approval inferred.
Calculated from: parallel-img1042-m007