Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1039 · Folder 192

Counters, transactions and administrative work

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial first-pass sequential visual review of public/archive/drawings/complete-upright/IMG_1039.webp after catalogue and OCR. Regions use unrotated access-image coordinates; rotationDegrees gives clockwise turn needed to read primary lettering. No room geometry or modeling inference. Partial timed visual review: Selected source-local properties; source-to-building placement and historical authority unestablished. Partial timed visual review: Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established. Partial timed visual review: undefined Partial timed visual review: Lower ornamental lantern companion detail only. Partial timed visual review: Selected source-local witness/callout review only; original and annotation layers kept separate.

Unresolved extraction work
  • full-sheet completeness
  • remaining notes, callouts, dimensions and hidden/cropped regions
  • floor and instance registration
  • Text reuse only; pending source readings retained. No new visual coverage or source-question closure.
  • Remaining dimension chains, fine fractions, all notes/schedules/callouts and companion details require regional review.
  • Original/revision authority, physical installation, floor/room registration and installed quantities remain unestablished; modeling and whole-building acceptance unchecked.
  • Fine fractions, witness endpoints and remaining dimension chains require targeted high-resolution review
  • Companion-sheet registration, revision reconciliation and physical instance placement remain outstanding
  • Modeling and whole-building acceptance checks not performed
  • Original versus revision authority and installed/as-built applicability unresolved.
  • Installed quantity, floor/room host, anchors and accepted source-to-building transform unresolved.
  • Remaining fine dimensions, schedules, notes and companion sections require review; modeling unchecked.
  • Pipe and wash fractions
  • Companion revision authority
  • Physical fixture placement
  • All remaining fine profiles, dimensions, witness endpoints, fabrication notes and schedules require regional review.
  • Original/revision and companion authority, installed quantities, floor/room placement and source-to-building registration unresolved; modeling unchecked.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

23 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1039-assemblyverified · printed

upper_ornament_point_quantity

14 POINTS

14 points

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 14 POINTS

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

ornamental_rib_quantity

14 RIBS

14 ribs

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 14 RIBS

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

lower_ornament_point_quantity

12 POINTS

12 points

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 12 POINTS

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

base_rosette_quantity

16 ROSETTES

16 rosettes

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 16 ROSETTES

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

pipe_material

IRON PIPE

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: IRON PIPE

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

pipe_coupling_material

IRON COUPLING

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: IRON COUPLING

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyunreviewed · printed

casting_flange

CAST [word unresolved] FLANGE

Unresolved source reading; numeric value withheld; partial review.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: CAST [word unresolved] FLANGE

Unresolved source reading; numeric value withheld; partial review.

parallel-img1039-assemblyverified · printed

bolt_quantity

4 - ½" BOLTS

4 bolts

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 4 - ½" BOLTS

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyverified · printed

bolt_diameter

4 - ½" BOLTS

0.5 in

Selected visually read source evidence; partial review; assembly-local scope only.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 4 - ½" BOLTS

Selected visually read source evidence; partial review; assembly-local scope only.

parallel-img1039-assemblyunreviewed · printed

stone_base_wash_slope

STONE BASE TO HAVE WASH OF ⅛" TO 1 CM. [unit lettering uncertain]

Unresolved source reading; numeric value withheld; partial review.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: STONE BASE TO HAVE WASH OF ⅛" TO 1 CM. [unit lettering uncertain]

Unresolved source reading; numeric value withheld; partial review.

parallel-img1039-assemblyunreviewed · printed

remaining_diameters_unresolved

[pipe diameter, cast washer/spokes and fabrication note unresolved]

Numeric value unresolved

Unresolved source reading; numeric value withheld; partial review.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: [pipe diameter, cast washer/spokes and fabrication note unresolved]

Unresolved source reading; numeric value withheld; partial review.

parallel-img1039-assemblyverified · printed

cast-washer-material-resolved

CAST IRON

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: CAST IRON

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

parallel-img1039-assemblyverified · printed

cast-washer-spokes

PLAN OF CAST W[ASHER] (4 SPOKES)

4 spokes

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: PLAN OF CAST W[ASHER] (4 SPOKES)

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

parallel-img1039-assemblyunreviewed · printed

flange-material-reading

CAST ALUMINUM FLANGE

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: CAST ALUMINUM FLANGE

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

parallel-img1039-assemblyunreviewed · printed

base-wash-reading

STONE BASE TO HAVE WASH OF 1/8 TO 1 [CM?]

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: STONE BASE TO HAVE WASH OF 1/8 TO 1 [CM?]

Additive source-local detail evidence; dimensions apply only to the depicted assembly. No room polygon, installed quantity, revision authority or accepted model placement established.

parallel-img1039-assemblyverified · printed

centering_flange_designation

CAST CENTERING FLANGE

Same left-side flange leader as earlier CAST [word unresolved]/CAST ALUMINUM FLANGE nulls. CENTERING is a functional designation; no alloy is established.

IMG_1039 · Locate on drawing ↗

Drawing notation: CAST CENTERING FLANGE

Same left-side flange leader as earlier CAST [word unresolved]/CAST ALUMINUM FLANGE nulls. CENTERING is a functional designation; no alloy is established.

parallel-img1039-assemblyverified · printed

upper_iron_pipe_nominal_size

3/8" IRON PIPE

0.375 in

Printed upper iron-pipe callout; nominal pipe size only, not outside diameter. Distinct from lower base pipe.

IMG_1039 · Locate on drawing ↗

Drawing notation: 3/8" IRON PIPE

Printed upper iron-pipe callout; nominal pipe size only, not outside diameter. Distinct from lower base pipe.

parallel-img1039-assemblyverified · printed

stone_base_wash_note

STONE BASE TO HAVE WASH OF 1/8 TO 1′-0″

Same stone-base wash note as prior two null transcriptions. Final denominator is architectural 1′-0″, not CM. Fraction 1/8 preserved without inventing a missing rise-unit glyph or deriving slope geometry.

IMG_1039 · Locate on drawing ↗

Drawing notation: STONE BASE TO HAVE WASH OF 1/8 TO 1′-0″

Same stone-base wash note as prior two null transcriptions. Final denominator is architectural 1′-0″, not CM. Fraction 1/8 preserved without inventing a missing rise-unit glyph or deriving slope geometry.

parallel-img1039-assemblyillegible · printed

lower_iron_pipe_fraction_followup

[1½ candidate] IRON PIPE

Numeric value unresolved

Lower base-pipe fraction remains ambiguous in the native crop. Distinct from the verified upper 3/8in leader.

IMG_1039 · Locate on drawing ↗

Drawing notation: [1½ candidate] IRON PIPE

Lower base-pipe fraction remains ambiguous in the native crop. Distinct from the verified upper 3/8in leader.

parallel-img1039-assemblyillegible · printed

lower_iron_pipe_fraction_and_unit_followup

[1½ candidate; unit mark unresolved] IRON PIPE

Numeric value unresolved

Same lower original base-pipe witness as pending candidate. Glyph and explicit unit remain insufficiently secure; no pipe size assigned. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: [1½ candidate; unit mark unresolved] IRON PIPE

Same lower original base-pipe witness as pending candidate. Glyph and explicit unit remain insufficiently secure; no pipe size assigned. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

parallel-img1039-assemblyverified · printed

stone_base_wash_rise_numeric_glyph

1/8

0.125 unlabeled-numeric-glyph

Wash rise fraction is visible without independently secure rise-unit mark. Numeric glyph only; no inch rise or numerical slope geometry assigned. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 1/8

Wash rise fraction is visible without independently secure rise-unit mark. Numeric glyph only; no inch rise or numerical slope geometry assigned. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

parallel-img1039-assemblyverified · printed

stone_base_wash_run_notation

1′-0″

12 in

Explicit denominator/run notation of same original stone-base wash note. Rise unit remains open, so this does not establish slope or surface geometry. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: 1′-0″

Explicit denominator/run notation of same original stone-base wash note. Rise unit remains open, so this does not establish slope or surface geometry. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

parallel-img1039-assemblyverified · printed

base_cast_web_designation

PLAN OF CAST WEB (4 SPOKES)

Lower base plan designation reads WEB; reused historical 4-spoke component count not repeated as installed quantity. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

IMG_1039 · W-575 · Locate on drawing ↗

Drawing notation: PLAN OF CAST WEB (4 SPOKES)

Lower base plan designation reads WEB; reused historical 4-spoke component count not repeated as installed quantity. Source-local only; no installed count, accepted geometry, revision authority or physical registration.

View all source photographs →