The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1079 · Folder 191

Broadway Elevation

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Bounded architectural wall-chain search; applicability reviewed, whole sheet not extracted. Partial timed visual review: Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established. Partial timed visual review: Printed source-reading resolution only; column pair is a view label, not a measured span. Partial timed visual review: undefined Partial timed visual review: Source-local printed detail/type evidence. FloorIds remain empty until physical instance registration; no installed quantity, world dimension, geometry or historical revision preference authorized. Partial timed visual review: Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Partial timed visual review: Structured partial first-pass repair of legacy coverage-only gap. Read existing reports/OCR before one <=1000px JPEG65 locator. No complete extraction/geometry claim. Source region is normalized access image; actual rotation0. Prior audit supplied sheet identity where recorded. Partial timed visual review: Text-only reuse of 1014i unresolved course spans. Existing verified same-locus upper column-label reading permits narrow text-question closure without re-viewing pixels.

Unresolved extraction work
  • classified interior finish-face location in the same W207/W403 section reference system
  • printed or independently controlled total perpendicular exterior-to-interior wall thickness
  • stone, backup, air space, waterproofing and room-side finish layer thicknesses with continuous endpoints
  • fourth-floor middle-bay applicability of each W207 local jamb/return condition
  • source-picked W-6 room-side face to W403 stone-face registration and independent check
  • masonry, frame, sash and clear-opening boundary reconciliation
  • complete W207/W208 callout, note and companion-detail coverage
  • Fine dimension fractions, witness endpoints and remaining small material callouts require targeted high-resolution review
  • Companion sheets, duplicate photographs and revision authority require reconciliation
  • Installed floor/room registration and whole-building modeling acceptance remain outstanding
  • Full wall section dimensions and connections
  • Revision and installed registration
  • 22-course less-one-joint groups apply to three pictured light-court upper sections, not Broadway street-wall thickness or installed quantities.
  • No course or joint thickness calculated from group span; complete head/window/steel/profile chains and datum unit/benchmark remain open.
  • Existing16-30/21-33 versus16-36 text history retained; new crop does not inspect that title token.
  • Classify finished/rough/masonry/frame witnesses and reconcile companion/source issue authority.
  • Installed room/floor instance and world transform remain unaccepted.
  • Remaining regional notes, sections, material schedules, fastenings and whole-source coverage remain partial.
  • Uninspected/cropped regions and unreadable dimension fractions remain open as listed in regional inventory
  • Remaining dimension chains, hardware, fasteners, schedules, finish/material exceptions and witness classes not fully extracted
  • Installed quantities, room/floor identities, revisions and companion authority unresolved
  • Broadway cornice soffit/elevation: Fine cornice/facade profile chains and dimensions
  • Light court roof/head sections and between-column 16–30 / 21–33 view: Fine steel/window profiles, layer widths, roof datum units/benchmark and connection dimensions
  • Light court lower sections and between-columns 16–20 view: Stone/brick/plaster/wall thickness endpoints; conditional wood sash sizes; radiator geometry
  • Light court title, steel-window applicability and provenance: Complete source/revision identity and reconciliation of wood/steel type applicability
  • Remaining fine fractions, witness endpoints, material/finish exceptions and regional notes require targeted review.
  • Original/revision and companion authority remains unreconciled; no historical layer selected.
  • Installed instances, quantities, floor/room hosts and physical registration remain unestablished; no modeling or architectural release.
  • Course modules belong light-court sections, not street-wall thickness.
  • Full cornice/head and radiator/member profiles, datum unit/benchmark and endpoint continuity remain open.
  • all remaining notes, dimensions and schedules
  • full-sheet completeness
  • original/annotation reconciliation and physical instance mapping

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

40 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

legacy-img1079-assemblyverified · printed

coping-material

TERRA COTTA COPING

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: TERRA COTTA COPING

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

legacy-img1079-assemblyverified · printed

roof-flashing

COPPER FLASHING

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: COPPER FLASHING

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

legacy-img1079-assemblyverified · printed

light-court-parapet-finish

CEMENT FINISH

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: CEMENT FINISH

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

legacy-img1079-assemblyunreviewed · printed

section-column-reading-conflict

SECTION BETWEEN COLUMNS 16-30 21-33

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: SECTION BETWEEN COLUMNS 16-30 21-33

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

legacy-img1079-assemblyverified · printed

steel-window-applicability

TYPICAL FOR STEEL WINDOWS IN EAST AND WEST WALLS OF LIGHT COURT

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: TYPICAL FOR STEEL WINDOWS IN EAST AND WEST WALLS OF LIGHT COURT

Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.

metal1012h-img1079-lightcourt-viewverified · printed

section_column_pair_reading_resolution

SECTION BETWEEN COLUMNS 16-30 21-33

Right upper label visibly reads 16-30; earlier 16-36 transcription in legacy coverage retained as a conflict. Lower 16-20 section remains separate.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: SECTION BETWEEN COLUMNS 16-30 21-33

Right upper label visibly reads 16-30; earlier 16-36 transcription in legacy coverage retained as a conflict. Lower 16-20 section remains separate.

legacy-img1079-assemblyverified · printed

left_upper_light_court_masonry_course_count

22 COURSES LESS ONE JOINT

22 course-count

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct left upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct left upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

legacy-img1079-assemblyillegible · printed

left_upper_light_court_masonry_course_span

22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Numeric value unresolved

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

legacy-img1079-assemblyverified · printed

middle_upper_light_court_masonry_course_count

22 COURSES LESS ONE JOINT

22 course-count

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct middle upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct middle upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

legacy-img1079-assemblyillegible · printed

middle_upper_light_court_masonry_course_span

22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Numeric value unresolved

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

legacy-img1079-assemblyverified · printed

right_upper_light_court_masonry_course_count

22 COURSES LESS ONE JOINT

22 course-count

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct right upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct right upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.

legacy-img1079-assemblyillegible · printed

right_upper_light_court_masonry_course_span

22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Numeric value unresolved

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]

Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.

legacy-img1079-assemblyverified · printed

right_upper_section_louver_material

COPPER LOUVERS

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Right upper light-court section louver leader.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: COPPER LOUVERS

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Right upper light-court section louver leader.

legacy-img1079-assemblyverified · printed

right_upper_section_screen_relationship

WITH SCREEN BEHIND

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Screen-behind-louvers relationship only; mesh/material/attachment dimensions unresolved.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: WITH SCREEN BEHIND

Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Screen-behind-louvers relationship only; mesh/material/attachment dimensions unresolved.

legacy-img1079-assemblyverified · printed

light-court-upper-leader-material

COPPER LEADER

Upper right light court wall section. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: COPPER LEADER

Upper right light court wall section. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-upper-leader-drip-material

WITH NICKEL DRIPS

Leader accessory only. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: WITH NICKEL DRIPS

Leader accessory only. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-reinforcement-companion-sheet

FOR SIZE & SPACING OF REINFORCING SEE STRUCTURAL DESIGN SHEET #419

419 sheet-number

Upper right light court section reinforcement reference. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: FOR SIZE & SPACING OF REINFORCING SEE STRUCTURAL DESIGN SHEET #419

Upper right light court section reinforcement reference. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-left-wall-facing-material

FACE BRICK

Left light court section; no street-facing material transfer. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: FACE BRICK

Left light court section; no street-facing material transfer. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-left-lower-window-material

WOOD SASH & FRAMES

Lower-left light court section; reconciles drawn wood option with sheet's separate steel-window applicability. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: WOOD SASH & FRAMES

Lower-left light court section; reconciles drawn wood option with sheet's separate steel-window applicability. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-radiator-location-condition

DOTTED LINES INDICATE RADIATORS IN 3RD 4TH & 5TH FLOORS

Conditional equipment location, not measured radiator size or quantities. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: DOTTED LINES INDICATE RADIATORS IN 3RD 4TH & 5TH FLOORS

Conditional equipment location, not measured radiator size or quantities. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-between-columns-16-20-finish

PLASTER CORNICE

Between-columns 16–20 section; distinct from 16–30 / 21–33. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: PLASTER CORNICE

Between-columns 16–20 section; distinct from 16–30 / 21–33. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-high-roof-datum-notation

H.P. ROOF ELEV. 195.42

Original numeric datum kept as notation; unit/benchmark not explicitly established here. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: H.P. ROOF ELEV. 195.42

Original numeric datum kept as notation; unit/benchmark not explicitly established here. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

light-court-low-roof-datum-notation

LOW POINT OF ROOF ELEV. 194.68

Distinct high/low roof annotations; no arbitrary datum transform. Source-local detail/type only; no installed quantity or physical placement.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: LOW POINT OF ROOF ELEV. 194.68

Distinct high/low roof annotations; no arbitrary datum transform. Source-local detail/type only; no installed quantity or physical placement.

legacy-img1079-assemblyverified · printed

left-upper-masonry-courses

19 COURSES

19 course-count

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Source-local masonry module count; not an installed building quantity.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 19 COURSES

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Source-local masonry module count; not an installed building quantity.

legacy-img1079-assemblyverified · printed

left-upper-masonry-course-span

19 COURSES 4′-3½″

51.5 in

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Left light-court section vertical witness from sill line to next slab/finish level.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 19 COURSES 4′-3½″

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Left light-court section vertical witness from sill line to next slab/finish level.

legacy-img1079-assemblyverified · printed

right-lower-module-course-count

12 COURSES LESS ONE JOINT

12 course-count

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Count in right 16–20 section module, with joint subtraction retained literally.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 12 COURSES LESS ONE JOINT

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Count in right 16–20 section module, with joint subtraction retained literally.

legacy-img1079-assemblyverified · printed

right-lower-module-course-span

12 COURSES LESS ONE JOINT = 2′-8½″

32.5 in

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section slab/beam-to-lower-head module. No course/joint thickness calculated.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 12 COURSES LESS ONE JOINT = 2′-8½″

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section slab/beam-to-lower-head module. No course/joint thickness calculated.

legacy-img1079-assemblyverified · printed

left-second-floor-course-count

16 COURSES

16 course-count

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate lower second-floor masonry module.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 16 COURSES

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate lower second-floor masonry module.

legacy-img1079-assemblyverified · printed

left-second-floor-course-span

16 COURSES 3′-7¼″

43.25 in

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Lower left course module from upper sill to second-floor line; separate from upper module.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 16 COURSES 3′-7¼″

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Lower left course module from upper sill to second-floor line; separate from upper module.

legacy-img1079-assemblyverified · printed

right-section-inner-drop

3′-1″

37 in

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section vertical extension from finished seventh-floor datum toward the beam zone; endpoint not a whole-room clear height.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 3′-1″

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section vertical extension from finished seventh-floor datum toward the beam zone; endpoint not a whole-room clear height.

legacy-img1079-assemblyverified · printed

right-section-ceiling-drop

4′-8″

56 in

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate right 16–20 finished-floor-to-plaster-cornice control.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: 4′-8″

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate right 16–20 finished-floor-to-plaster-cornice control.

legacy-img1079-assemblyverified · printed

left-dampproofing-note

DAMPPROOFING

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed left wall leader; distinct from membrane waterproofing and lead flashing.

IMG_1079 · W-208 · Locate on drawing ↗

Drawing notation: DAMPPROOFING

Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed left wall leader; distinct from membrane waterproofing and lead flashing.

legacy-img1079-assemblyverified · printed

sheet_number

W208

208 drawing-number

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: W208

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · printed

cornice_view

SOFFIT OF MAIN CORNICE

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: SOFFIT OF MAIN CORNICE

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · printed

facade_title

DETAIL OF UPPER STORIES BROADWAY ELEVATION

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: DETAIL OF UPPER STORIES BROADWAY ELEVATION

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · printed

section_scope

SECTIONS THRU LIGHT COURT WALLS

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: SECTIONS THRU LIGHT COURT WALLS

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · printed

section_column_pair

SECTION BETWEEN COLUMNS 16-20

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: SECTION BETWEEN COLUMNS 16-20

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · printed

section_column_pairs_upper

SECTION BETWEEN COLUMNS 16-36 21-33

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: SECTION BETWEEN COLUMNS 16-36 21-33

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyverified · observed

wall_chain_limitation

Named right-side sections concern light court walls, not street wall thickness

Selected printed source or documented prior audit; partial source-local review.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: Named right-side sections concern light court walls, not street wall thickness

Selected printed source or documented prior audit; partial source-local review.

legacy-img1079-assemblyunreviewed · printed

remaining_material_dimensions_unresolved

[floor heights, layer/material codes and dimension endpoints too small]

Numeric value unresolved

Tentative or unresolved locator; numeric value withheld.

IMG_1079 · W208 · Locate on drawing ↗

Drawing notation: [floor heights, layer/material codes and dimension endpoints too small]

Tentative or unresolved locator; numeric value withheld.

View all source photographs →