Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1193-vaultverified · printed
assembly_assignment
FIRE PROOF VAULT AND CLOSET DOORSSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: FIRE PROOF VAULT AND CLOSET DOORS
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vaultverified · printed
all_vault_finish
NOTE: INTERIOR OF ALL VAULTS UNPLASTEREDSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: NOTE: INTERIOR OF ALL VAULTS UNPLASTERED
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vaultunreviewed · printed
dimensions_remaining
UnresolvedNumeric value unresolved
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-closetverified · printed
assembly_scope
DETAILS OF DOORS, FRAME ETC. FOR CLOSETS OVER VAULTS WHERE SUCH ARE REQUIRED BY GENERAL BUILDING DRAWINGSSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: DETAILS OF DOORS, FRAME ETC. FOR CLOSETS OVER VAULTS WHERE SUCH ARE REQUIRED BY GENERAL BUILDING DRAWINGS
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-closetverified · printed
door_width
3'-0"36 in
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-closetverified · observed
substrate_conditions
Applications to concrete wall, steel-lined vault and brick wall separately depictedSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: Applications to concrete wall, steel-lined vault and brick wall separately depicted
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-hingeverified · printed
detail_scope
HALF FULL SIZE DETAIL OF HINGES FOR OUTER DOOR TO VAULTSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: HALF FULL SIZE DETAIL OF HINGES FOR OUTER DOOR TO VAULT
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-hingeunreviewed · printed
hinge_similarity
These are inner doors; same on outer & back door as to size [exact wording unresolved]Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: These are inner doors; same on outer & back door as to size [exact wording unresolved]
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
brick_wall_application
GENERAL PLAN VESTIBULE DOORS ETC. TO VAULT AS APPLIED TO OPENING IN BRICK WALLSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: GENERAL PLAN VESTIBULE DOORS ETC. TO VAULT AS APPLIED TO OPENING IN BRICK WALL
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
left_hang_note
Where plans of building show doors to hang on left side this construction of frame must be reversedSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: Where plans of building show doors to hang on left side this construction of frame must be reversed
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
detail_identity
DETAIL OF VESTIBULE DOORS ETC. TO VAULTSelected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: DETAIL OF VESTIBULE DOORS ETC. TO VAULT
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
concrete_application_width
3'-0"36 in
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
steel_lined_application_width
3'-0"36 in
Selected source evidence only; partial locator review. Applies to depicted historical drawing, not accepted building geometry.
parallel-img1193-vestibuleverified · printed
brick_wall_plan_scale
Scale: 3" = 1 Ft.3 in_per_ft
Drawing-specific detail or historical survey evidence; installed instance and geometry not established.
parallel-img1193-hingeverified · printed
hinge_similarity_exact_clause
Those for inner door to same and doors to closet over to be similar.Exact two-line clause immediately below HALF FULL SIZE DETAIL OF HINGES FOR OUTER DOOR TO VAULT. No same-size dimension or back-door statement is established.
IMG_1193 · M-352-F · Locate on drawing ↗Drawing notation: Those for inner door to same and doors to closet over to be similar.
Exact two-line clause immediately below HALF FULL SIZE DETAIL OF HINGES FOR OUTER DOOR TO VAULT. No same-size dimension or back-door statement is established.