printed room title
LIBRARY CIRCUIT COURT OF APPEALS ROOM 714Authoring eligible: false. Source audit state: verified.
Drawing notation: LIBRARY CIRCUIT COURT OF APPEALS ROOM 714
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Sheet number unresolved
Extraction: Reviewed · extraction partial. drawing title and material/finish note; north, south and east wall elevations plus west-wall same-reverse instruction; north, south, east and west wall plan strips; circled detail/profile marks A-S; upper profile, moulding, jamb and track studies; contractor field-verification note; yellow dimension/material revisions; title/revision area Partial timed visual review: Bounded source-witness extraction; historical readings and regional inventory reused. Partial timed visual review: Coordinates normalized in encoded access derivative. Source-local documentary evidence only; no installed transform. Partial timed visual review: Additive source-local review. Coordinates refer to encoded access derivative before presentation rotation. No installed transform or geometry acceptance. Partial timed visual review: undefined
Loading the selected drawing…
Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.
Open source image separately ↗Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
Authoring eligible: false. Source audit state: verified.
Drawing notation: LIBRARY CIRCUIT COURT OF APPEALS ROOM 714
3 count
Authoring eligible: false. Source audit state: verified-composition-count; four room walls represented.
Drawing notation: NORTH WALL; SOUTH WALL; ELEVATION EAST WALL / WEST WALL SAME REVERSE
19 count
Authoring eligible: false. Source audit state: verified-mark-presence; complete one-to-one instance map unresolved.
Drawing notation: circled A-S
Authoring eligible: false. Source audit state: verified.
Drawing notation: NOTE:- CONTRACTOR TO VERIFY ALL MEASUREMENTS & CONDITIONS ON JOB.
6 ft
Authoring eligible: false. Source audit state: verified-glyph; endpoint member faces not classified.
Drawing notation: 6'-0"
7.552083 ft
Authoring eligible: false. Source audit state: probable-transcription; endpoint classification and member ownership unresolved.
Drawing notation: 7'-6 5/8"
2.291667 ft
Authoring eligible: false. Source audit state: verified-glyph; exact member endpoints unresolved.
Drawing notation: 2'-3 1/2"
3 in
Authoring eligible: false. Source audit state: verified-revision-glyph; original superseded value and exact member classes unresolved. Conflict group: library714-img0931-plan-span-revision-conflict.
Drawing notation: 3"
Authoring eligible: false. Source audit state: explicit-null. Conflict group: library714-img0931-plan-span-revision-conflict.
7 ft
Authoring eligible: false. Source audit state: verified-glyph and local vertical endpoints; opening-to-plan identity unresolved.
Drawing notation: 7'-0"
Authoring eligible: false. Source audit state: verified-word; exact member scope unresolved. Conflict group: library714-img0931-wood-species-revision.
Drawing notation: Mahogany
Authoring eligible: false. Source audit state: explicit-null. Conflict group: library714-img0931-wood-species-revision.
Authoring eligible: false. Source audit state: partial; remaining words and approved sample unavailable.
Drawing notation: Stain to match approved sample ...
Authoring eligible: false. Source audit state: partial; species/facing scope unresolved.
Drawing notation: Shelves ...
2 count
Authoring eligible: false. Source audit state: verified core instruction; trailing service-purpose sentence only partially legible.
Drawing notation: LOWER TRACK TO BE IN TWO PIECES WITH JOINT HERE
The drawing explicitly requires contractor verification of measurements and job conditions. Complete wall lengths, vertical stacks, bay widths, panel/door/shelf quantities, profiles and dimension endpoints are not all readable or classified. The drawing is an oblique photograph with folds and local perspective; paper line lengths cannot be scaled safely. Original values and material words beneath yellow review markup remain obscured. The south-wall opening-like bays are not cross-walked one-to-one to f7-door-714-715 and f7-door-714-716. No fixture instances are safely classified. No checked IMG_0931 wall-elevation-to-plan or source-to-world transform exists.
North-wall elevation and adjacent north-wall plan strip, including the 6'-0" and 7'-6 5/8" controls and lettered detail callouts.
East-wall elevation with the printed instruction that the west wall is the same in reverse; repeated sliding-door/panel fields and lower panels.
South-wall elevation, two opening-like bays, fitted panel/casework fields, section A-A, and the 7'-0" opening-height control.
North, south, east and west wall plan strips and local member/track dimensions.
W8 / IMG_1219 is the sixth-floor plan. Room 714 is on the seventh floor, so a direct IMG_0931-to-W8 fit would be a floor-category error. W8 may inform shared building axes only through existing project conventions; it cannot place Room 714 millwork. The existing Room 714 polygon has 3.25-foot conservative uncertainty and unreviewed finish faces. IMG_0931 supplies wall-specific millwork plans/elevations but no accepted common controls, no scale-bearing whole-room plan and no checked orientation correspondence.
North-wall elevation and adjacent north-wall plan strip, including the 6'-0" and 7'-6 5/8" controls and lettered detail callouts.
East-wall elevation with the printed instruction that the west wall is the same in reverse; repeated sliding-door/panel fields and lower panels.
South-wall elevation, two opening-like bays, fitted panel/casework fields, section A-A, and the 7'-0" opening-height control.
North, south, east and west wall plan strips and local member/track dimensions.
Only wall strips and elevations are shown; there is no complete orthogonal room plan with accepted common control points. Folds and perspective vary across the photographed sheet. Several candidate controls are revision annotations with obscured originals. Plan/elevation endpoints are not consistently classified as finish face, frame face, track centerline or member edge. No independent held-out checks can be formed without opening and registering a companion source.
North-wall elevation and adjacent north-wall plan strip, including the 6'-0" and 7'-6 5/8" controls and lettered detail callouts.
East-wall elevation with the printed instruction that the west wall is the same in reverse; repeated sliding-door/panel fields and lower panels.
South-wall elevation, two opening-like bays, fitted panel/casework fields, section A-A, and the 7'-0" opening-height control.
North, south, east and west wall plan strips and local member/track dimensions.
Original white-line exposed-material clause. Phil abbreviation is literal, not expanded. It remains separate from adjacent yellow revision text. Source-local reading only; installation, revision authority and geometry remain unchecked.
Drawing notation: Doors and exposed parts Phil Mahogany Hard close ribbon grain
Original white-line exposed-material clause. Phil abbreviation is literal, not expanded. It remains separate from adjacent yellow revision text. Source-local reading only; installation, revision authority and geometry remain unchecked.
Original white-line shelves clause. Circled White Pine and tops remain literal original words; yellow revision authority and exact installed shelf facing remain open. Source-local reading only; installation, revision authority and geometry remain unchecked.
Drawing notation: Shelves White Pine with Mahogany tops
Original white-line shelves clause. Circled White Pine and tops remain literal original words; yellow revision authority and exact installed shelf facing remain open. Source-local reading only; installation, revision authority and geometry remain unchecked.
Original white-line standards/back clause; adjacent yellow Mahogany stays separate. No installed material or revision selection. Source-local reading only; installation, revision authority and geometry remain unchecked.
Drawing notation: Standards and fixed nailed backs White Pine
Original white-line standards/back clause; adjacent yellow Mahogany stays separate. No installed material or revision selection. Source-local reading only; installation, revision authority and geometry remain unchecked.
Complete printed source clause in this IMG0931 witness. The physical approved sample, shellac/varnish product and installed finish remain unavailable. Source-local reading only; installation, revision authority and geometry remain unchecked.
Drawing notation: Stain to match approved sample for a shellac and Varnish finish by others
Complete printed source clause in this IMG0931 witness. The physical approved sample, shellac/varnish product and installed finish remain unavailable. Source-local reading only; installation, revision authority and geometry remain unchecked.
Completes service sentence below previously recorded two-piece lower-track joint note. Removal of track sections enables door removal; no fastener or door count implied.
Drawing notation: IT BEING NECESSARY TO REMOVE SECTIONS IN ORDER TO REMOVE A DOOR WHEN NECESSARY
Completes service sentence below previously recorded two-piece lower-track joint note. Removal of track sections enables door removal; no fastener or door count implied.