Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_0914 · Folder 195

TYPICAL DOORS

Sheet 54

Extraction: Reviewed · extraction partial. complete sheet; construction details; eleven elevation columns; schedule grid overview; notes/title block Partial timed visual review: Existing text evidence reused; no new image inspection in this bounded pass. Partial timed visual review: Complete door schedule; prior cells and inventory reused. Source-local extraction only; original/revision and installation layers remain separate.

Unresolved extraction work
  • complete cell-by-cell transcription
  • all quantities and materials
  • column/elevation labels
  • rooms 603/604/610/611 cell ownership
  • shower-stall envelope
  • panel dimensions
  • frames, swings, hardware and installed locations
  • Complete schedule cell transcription
  • Column/elevation mapping and room assignments
  • Frames/hardware
  • Full-region completeness and physical placement remain unestablished.
  • Complete cell-by-cell schedule; all rows/columns, quantities, materials, marks and corrections
  • Opening/frame/swing/hardware and installed-room crosswalk
  • All remaining fine dimensions, endpoints, profiles, schedules, quantities and companion clauses require region-by-region review.
  • Source-to-room/wall registration, original/revision authority and physical installation remain unresolved; modeling unchecked.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

12 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

typical-doors-img0914-registerverified · observed

visible_schedule_column_count

11 columns

11 count

Physical geometry eligible: false. Source audit state: verified.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: eight general door elevations plus TOILET STALL, FLY DOOR and SHOWER STALL

Eight general door elevations plus toilet-stall, fly and shower-stall elevations.

typical-doors-img0914-registerverified · printed

floor_band_count

9 floor bands

9 count

Physical geometry eligible: false. Source audit state: verified.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: BASEMENT; FIRST FL.; SECOND FL.; THIRD FL.; FOURTH FL.; FIFTH FL.; SIXTH FL.; SEVENTH FL.; EIGHTH FL.

Basement through eighth-floor schedule grid.

typical-doors-img0914-standard-3x7-envelopeverified · printed

width

3 ft 0 in.

3 ft

Physical geometry eligible: false. Source audit state: verified repeated envelope; instance crosswalk incomplete.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 3-0 x 7-0

Basement through eighth-floor schedule grid.

typical-doors-img0914-standard-3x7-envelopeverified · printed

height

7 ft 0 in.

7 ft

Physical geometry eligible: false. Source audit state: verified repeated envelope; instance crosswalk incomplete.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 3-0 x 7-0

Basement through eighth-floor schedule grid.

typical-doors-img0914-standard-3x7-envelopeverified · printed

thickness

1 3/4 in.

1.75 in

Physical geometry eligible: false. Source audit state: verified repeated envelope; construction/material varies by cell.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 1 3/4

Basement through eighth-floor schedule grid.

typical-doors-img0914-toilet-stall-typeverified · printed

width

2 ft 4 in.

2.333333 ft

Physical geometry eligible: false. Source audit state: verified.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 2-4

Eight general door elevations plus toilet-stall, fly and shower-stall elevations.

typical-doors-img0914-toilet-stall-typeverified · printed

height

5 ft 0 in.

5 ft

Physical geometry eligible: false. Source audit state: verified.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 5-0

Eight general door elevations plus toilet-stall, fly and shower-stall elevations.

typical-doors-img0914-fly-door-typeverified · printed

height

5 ft 0 in.

5 ft

Physical geometry eligible: false. Source audit state: verified.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: 5-0

Eight general door elevations plus toilet-stall, fly and shower-stall elevations.

typical-doors-img0914-registerunreviewed · printed

complete_cell_by_cell_schedule

Incomplete

Physical geometry eligible: false. Source audit state: explicit-null pending IMG_0915 companion audit.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: quantities, sizes, thicknesses, veneers and notes across basement through eighth floor

Basement through eighth-floor schedule grid.

typical-doors-img0914-registerverified · observed

Physical and installed door geometry gate

FAIL — first-pass schedule structure and local envelopes only

cell-by-cell transcription incomplete alternate exposure IMG_0915 not reconciled elevation-to-column labels not fully transcribed materials and core notes vary by cell opening-instance crosswalk absent frames, swings and hardware not established world transforms absent

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: TYPICAL DOORS

Complete typical-door schedule sheet.

typical-doors-img0914-registerverified · derived

Source-linked analytical door envelopes permitted

Permitted; not physical doors or installed openings

1 count

Permit source-local wire envelopes for the repeated 3 x 7, toilet-stall and fly-door controls only. Do not create panels, cores, frames, hardware or installed door instances.

IMG_0914 · shop-drawing-54-IMG0914 · Locate on drawing ↗

Drawing notation: TYPICAL DOORS

Complete typical-door schedule sheet.

View all source photographs →