Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1089 · Folder 191

TYPICAL DETAILS OF LOBBY FLOOR & CEILING & 1/8" ELEV. / OF LOBBY, FOYER & BROADWAY FOYER

Sheet W214

Extraction: Reviewed · extraction partial. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence. Normalized from an existing text re-audit; this import did not reopen the source image. Partial timed visual review: Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established. Partial timed visual review: Selected note clauses read. Remaining floor/door applicability, parenthetical wording and stainless-steel exception are not safely complete; broad prior questions retained. Partial timed visual review: Source-local specification only; installed placement, quantity and physical geometry remain unestablished. Partial timed visual review: undefined

Unresolved extraction work
  • Complete drawing-note transcription
  • Every dimension and bay placement
  • Detailed hardware/fastener schedule
  • Exact cross-sheet bay correspondence
  • Cross-photo physical deduplication
  • Complete surviving-object inventory
  • Exact dimensions
  • Construction/alteration chronology
  • Condition assessment
  • P-6 component extraction
  • Installed fixture schedule and positions
  • As-built correspondence
  • Fixture finish and glass color
  • Fine fractions and complete witness endpoints require targeted high-resolution crops
  • Companion captures, material code and revision authority require reconciliation
  • Installed floor/room registration, exact depths and modeling checks outstanding
  • Exact bronze floor/elevator applicability, complete stainless-steel exception and plain-surface parenthetical require another witness; all bay dimensions/instances remain open.
  • Remaining notes, dimensions, endpoint classes and companion details outside the bounded crop require review.
  • Historical issue/revision authority, installed instances, quantities and physical registration remain unresolved; no geometry or architectural acceptance.
  • Remaining fine specification text
  • Full dimensional endpoints and companion details
  • Accepted physical registration and revision reconciliation
  • Exact ceiling-chain endpoints, grille construction, panel type correspondence and all remaining dimension strings.
  • Broad lobby ornamental-plaster applicability and finish remains unresolved.
  • Remaining notes, fine fractions, complete endpoints and companion details are not exhaustively reviewed.
  • Installed instances, quantity, governing issue, physical registration and whole-building acceptance remain unresolved.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

16 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f1-public-lobby-postal-wall-systemunreviewed · observed

typical_service_module_width

customer counter modules repeatedly read about 7 feet 6 inches

The report describes a repeated approximate reading without accepted station assignments.

IMG_1202 · sheet-W3 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing verified package; image not reopened. Named PUBLIC LOBBY and printed ceiling-height reading

IMG_1204 · sheet-W3 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only; image not reopened. First-floor public-lobby plan, reported 18'-3" ceiling-height reading and repeated 14'/15' structural dimensions

IMG_1089 · sheet-W214 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence

IMG_1302 · sheet-W214 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence

IMG_1090 · sheet-W215 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks

IMG_1091 · sheet-W215 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks

IMG_1092 · sheet-W215 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks

IMG_1303 · sheet-W215 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Bays E, I, K and B; bronze/glass screens, Letters/Packages, Registry, counters, money drawer and locks

IMG_1093 · sheet-W216 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign

IMG_1094 · sheet-W216 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign

IMG_1304 · sheet-W216 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit only. Parcel Post/Registry windows, roll-down curtains, staff-side casework and illuminated STAMPS sign

IMG_1095 · sheet-W217 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays

IMG_1097 · sheet-W217 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays

IMG_1098 · sheet-W217 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays

IMG_1305 · sheet-W217 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing verified elevator package; images not reopened. Bay P directory, paired door, Elevator No. 2 entrance, clock and other glazed door/screen bays

IMG_1099 · sheet-W-218 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing writing-desk packages; images not reopened. Main Street foyer/lobby door-screen line, bulletin cases, bronze directory and lobby furniture family

IMG_1306 · sheet-W-218 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing text re-audit and existing writing-desk packages; images not reopened. Main Street foyer/lobby door-screen line, bulletin cases, bronze directory and lobby furniture family

IMG_1289 · sheet-WLF-246 · View drawing ↗

Drawing notation: customer counter modules repeatedly read about 7 feet 6 inches

Existing verified package plus re-audit report; image not reopened. P-5 Public Lobby and P-6 Registry/Box/Parcel Post alcove fixture types

material-lobby-ornamental-plasterunreviewed · observed

Applications and finish

coffer panels and borders; transverse beams; continuous cornice

drawing re-audit and 1983 observed condition. Report transcription; physical thickness, joint layout and finish samples remain unresolved.

IMG_1089 · sheet-W214 · View drawing ↗

Drawing notation: Modeled ornamental plaster ceiling and cornice

Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence

IMG_1302 · sheet-W214 · View drawing ↗

Drawing notation: Modeled ornamental plaster ceiling and cornice

Existing text re-audit only. Lobby overview, floor/ceiling bay grid, Panels A-D and service-wall sequence

parallel-img1089-overviewunreviewed · printed

unresolved-metal-general-notes

METAL: [remaining general specification lines unresolved]

Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: METAL: [remaining general specification lines unresolved]

Source-local drawing evidence only; installed quantity, accepted world placement and physical geometry not established.

parallel-img1089-overviewverified · printed

elevator_cab_door_main_finish_clause

ELEVATOR CABS, CAB DOORS & ALL ELEVATOR DOORS NOT HERETOFORE NOTED AS BEING BRONZE TO BE BAKED ENAMEL FINISH ON STEEL

Main finish clause only. Following EXCEPT clause refers to stainless steel but exact floor/door wording is not safely transcribed; prior complete exception question remains open. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: ELEVATOR CABS, CAB DOORS & ALL ELEVATOR DOORS NOT HERETOFORE NOTED AS BEING BRONZE TO BE BAKED ENAMEL FINISH ON STEEL

Main finish clause only. Following EXCEPT clause refers to stainless steel but exact floor/door wording is not safely transcribed; prior complete exception question remains open. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

parallel-img1089-overviewverified · printed

plain_surface_extrusion_fragment

BRONZE TO BE EXTRUDED

Verified terminal material/fabrication fragment only. Parenthetical and full plain-surface applicability wording remain unresolved, so neither prior general fabrication question is closed. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: BRONZE TO BE EXTRUDED

Verified terminal material/fabrication fragment only. Parenthetical and full plain-surface applicability wording remain unresolved, so neither prior general fabrication question is closed. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

parallel-img1089-overviewverified · printed

wall_base_marble_specification

WALLS AND BASE TO BE PINK KASOTA FLEURI.

Separate MARBLE wall/base clause in general notes; material designation only, no thickness or installed layout. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: WALLS AND BASE TO BE PINK KASOTA FLEURI.

Separate MARBLE wall/base clause in general notes; material designation only, no thickness or installed layout. Source-local reading only; no installed quantity, physical geometry or historical issue authority established.

parallel-img1089-overviewunreviewed · printed

general_metal_scope_candidate

ALL CORNICE, TRIM, DOORS & GRILLES IN LOBBY, DIRECTORY & BULLETIN BOARDS, DOORS TO ELEVATORS AT BASEMENT, TO ELEVATORS 1 & 2 AND [remaining applicability clause unresolved] TO BE OF BRONZE.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: ALL CORNICE, TRIM, DOORS & GRILLES IN LOBBY, DIRECTORY & BULLETIN BOARDS, DOORS TO ELEVATORS AT BASEMENT, TO ELEVATORS 1 & 2 AND [remaining applicability clause unresolved] TO BE OF BRONZE.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

parallel-img1089-overviewverified · printed

general_grille_rail_material

GRILLES & RAILING IN ELEVATOR CABS TO BE BRONZE AS NOTED.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: GRILLES & RAILING IN ELEVATOR CABS TO BE BRONZE AS NOTED.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

parallel-img1089-overviewunreviewed · printed

cab_material_exception_candidate

ELEVATOR CABS, CAB DOORS & ALL ELEVATOR DOORS NOT MENTIONED ABOVE [remaining metal and finish clause unresolved].

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: ELEVATOR CABS, CAB DOORS & ALL ELEVATOR DOORS NOT MENTIONED ABOVE [remaining metal and finish clause unresolved].

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

parallel-img1089-overviewunreviewed · printed

plain_surface_fabrication

[Metal specification line below elevator-cab clause: parenthetical exception and fabrication wording unresolved]

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: [Metal specification line below elevator-cab clause: parenthetical exception and fabrication wording unresolved]

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

parallel-img1089-overviewunreviewed · printed

surface_finish_requirement

PLAIN SURFACES ... BRONZE TO BE EXTRUDED [intervening wording unresolved]

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: PLAIN SURFACES ... BRONZE TO BE EXTRUDED [intervening wording unresolved]

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

parallel-img1089-overviewverified · printed

countertop_exception

EXCEPT COUNTER TOPS & DEAL PLATES. ORNAMENTED SURFACES TO BE CAST.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: EXCEPT COUNTER TOPS & DEAL PLATES. ORNAMENTED SURFACES TO BE CAST.

Source-local specification only; installed placement, quantity and physical geometry remain unestablished.

postal1014u-1089-ceiling-planverified · printed

ceiling_ornament_repeat_instruction

REPEAT CAST PLASTER ORNAMENT AS SHOWN FOR MAIN CEILING

Full horizontal instruction above the left panel group. Establishes cast-plaster ornament and repetition instruction in this ceiling-plan detail only. It does not establish all lobby plaster applications, finish or thickness and does not close the broad material applicability question.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: REPEAT CAST PLASTER ORNAMENT AS SHOWN FOR MAIN CEILING

Full horizontal instruction above the left panel group. Establishes cast-plaster ornament and repetition instruction in this ceiling-plan detail only. It does not establish all lobby plaster applications, finish or thickness and does not close the broad material applicability question.

postal1014u-1089-ceiling-planverified · printed

ceiling_plan_horizontal_chain_witness

14′-0″

168 in

Printed horizontal witness within the main-ceiling half-plan, crossing the repeated-panel group. Source-local chain only: endpoints' structural/finished classifications and mapping to installed bay remain unestablished; not a service-counter module width.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: 14′-0″

Printed horizontal witness within the main-ceiling half-plan, crossing the repeated-panel group. Source-local chain only: endpoints' structural/finished classifications and mapping to installed bay remain unestablished; not a service-counter module width.

postal1014u-1089-panel-cverified · printed

adjacent_model_mark

MODEL NO 13

Circled model-number mark adjacent lower-right corner of labeled PANEL C; mark is a type/reference identifier, not quantity. Exact model catalogue and propagation to repeated panels remain unresolved.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: MODEL NO 13

Circled model-number mark adjacent lower-right corner of labeled PANEL C; mark is a type/reference identifier, not quantity. Exact model catalogue and propagation to repeated panels remain unresolved.

postal1014u-1089-panel-d-rightverified · printed

adjacent_model_mark

MODEL NO 14

Circled model-number mark adjacent upper-right corner of right labeled PANEL D. Identifier only; not installed quantity or authority to copy the mark to all D panels.

IMG_1089 · W-214 · Locate on drawing ↗

Drawing notation: MODEL NO 14

Circled model-number mark adjacent upper-right corner of right labeled PANEL D. Identifier only; not installed quantity or authority to copy the mark to all D panels.

View all source photographs →