Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1153 · Folder 191

Lookout

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial locator review after catalogue/OCR using <=1000px JPEG65 derivative of public/archive/drawings/complete-upright/IMG_1153.webp. Lettering upright. Regions are original access-image normalized coordinates. Locating a region does not claim full review of its fine detail. No modeling. Partial timed visual review: Additive bounded remaining-region review of upright WebP after queue, OCR and prior packages; no geometry acceptance. Partial timed visual review: Additive targeted review; source-local details only. No installed quantities, finished room geometry or model acceptance established. Partial timed visual review: Prior finish/material/fixture text findings reused; source not reopened and no duplicate properties added. Partial timed visual review: Source-local view inventory and selective notes/individual properties; repeated-photo correspondence does not establish revision equivalence, installed quantity or exact geometry. Partial timed visual review: Selected source-local properties; source remains incomplete.

Unresolved extraction work
  • complete review of each region and fine note
  • remaining dimensions, materials, schedules, callouts and revisions
  • floor/object registration and cropped companion evidence
  • Fine fractional dimensions and classified extension endpoints in remaining regions
  • Complete individual component inventory and companion-sheet/revision reconciliation
  • Accepted source-to-building transform and actual installed geometry
  • Remaining regions, fine fractions and extension endpoints need review
  • Installed instance mapping and accepted source-to-building transform
  • Companion details and revision reconciliation
  • Remaining dimensions, fractions, endpoint classification and revision reconciliation
  • Installed instance mapping and governing finish schedules
  • Accepted source-to-building transform and full region extraction remain outstanding
  • Full high-resolution fine-fraction and endpoint review of each inventoried view remains
  • Handwriting, original/revision dates, approved samples and source precedence remain unclosed
  • Companion detail matching and source-to-installed-object / room registration remain
  • Cropped views need corresponding source photographs; missing evidence has not been declared irrecoverable
  • Individual objects retain specific missing properties; no source or floor completed by this inventory
  • Paint instruction locus, floor-layer thicknesses, observation-unit variants and remaining channel/bolt sizes unresolved.
  • Installed instances, full component dimensions and hardware specifications remain unresolved.
  • Governing revisions, companion details and source-to-building registration remain unresolved.
  • No geometry acceptance or architectural release; all unreviewed source regions remain open.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

27 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1153-assemblyverified · printed

observation_hole

PLAN LOOKING UP OBSERVATION FLOOR HOLE

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: PLAN LOOKING UP OBSERVATION FLOOR HOLE

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

crosswise_anchor_method

METHOD OF ANCHORING WHEN 4" CHANNELS RUN CROSSWISE OF SUPPORTS

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: METHOD OF ANCHORING WHEN 4" CHANNELS RUN CROSSWISE OF SUPPORTS

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

channel_size

4" CHANNELS

4 in

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: 4" CHANNELS

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

basement_plan

TYPICAL PLAN OF BASEMENT LOOKOUT GALLERY

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: TYPICAL PLAN OF BASEMENT LOOKOUT GALLERY

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

first_floor_plan

TYPICAL PLAN OF FIRST FLOOR LOOKOUT GALLERY

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: TYPICAL PLAN OF FIRST FLOOR LOOKOUT GALLERY

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

finished_floor_scope

FINISHED FLOOR CONSTRUCTION FOR ALL BUT BASEMENT FLOOR; FOR B'SMT. FL. SEE NOTE ON SHEET #2

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: FINISHED FLOOR CONSTRUCTION FOR ALL BUT BASEMENT FLOOR; FOR B'SMT. FL. SEE NOTE ON SHEET #2

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_type_wood_block

WOOD BLOCK FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: WOOD BLOCK FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_type_terrazzo

TERRAZZO FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: TERRAZZO FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_type_marble

MARBLE FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: MARBLE FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_type_linoleum

LINOLEUM FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: LINOLEUM FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_type_tile

TILE FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: TILE FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyverified · printed

floor_build_up_base

TOP OF CONCRETE SLABS

Selected legible locator evidence; partial assembly-local extraction.

IMG_1153 · Locate on drawing ↗

Drawing notation: TOP OF CONCRETE SLABS

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1153-assemblyunreviewed · printed

metal_plate_paint_instruction

METAL PLATE TO BE ... NOT PAINTED [remaining words unresolved]

Uncertain locator reading; value withheld; full detail review outstanding.

IMG_1153 · Locate on drawing ↗

Drawing notation: METAL PLATE TO BE ... NOT PAINTED [remaining words unresolved]

Uncertain locator reading; value withheld; full detail review outstanding.

parallel-img1153-assemblyunreviewed · printed

floor_layer_thicknesses_unresolved

[finish, concrete fill, lockstrip, slab thicknesses and channel/bolt fine labels unresolved]

Numeric value unresolved

Uncertain locator reading; value withheld; full detail review outstanding.

IMG_1153 · Locate on drawing ↗

Drawing notation: [finish, concrete fill, lockstrip, slab thicknesses and channel/bolt fine labels unresolved]

Uncertain locator reading; value withheld; full detail review outstanding.

detail-lookout-observation-unit-1153verified · printed

observation-slot-width

3/8" WIDE

0.375 in

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1153 · Locate on drawing ↗

Drawing notation: 3/8" WIDE

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-observation-unit-1153verified · printed

observation-slot-length

1'-0" LONG

12 in

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1153 · Locate on drawing ↗

Drawing notation: 1'-0" LONG

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-observation-unit-1153manual-source-review · printed

fabrication-note

OBS. UNIT: 3/16" THICK MADE IN ONE PIECE & SECURED AT EACH END TO METAL FLATS

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1153 · Locate on drawing ↗

Drawing notation: OBS. UNIT: 3/16" THICK MADE IN ONE PIECE & SECURED AT EACH END TO METAL FLATS

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-observation-unit-1153manual-source-review · printed

observation-unit-thickness

3/16" THICK

0.1875 in

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1153 · Locate on drawing ↗

Drawing notation: 3/16" THICK

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-floor-woodblock-1153manual-source-review · printed

overall-build-up-above-slab

5"

5 in

Printed dimension between finished floor top and top of concrete slab in wood block detail; photograph geometry not scaled.

IMG_1153 · Locate on drawing ↗

Drawing notation: 5"

Printed dimension between finished floor top and top of concrete slab in wood block detail; photograph geometry not scaled.

detail-lookout-floor-linoleum-1153manual-source-review · printed

overall-build-up-above-slab

4"

4 in

Printed dimension between finished-floor top and top of concrete slab; individual layer thicknesses unresolved.

IMG_1153 · Locate on drawing ↗

Drawing notation: 4"

Printed dimension between finished-floor top and top of concrete slab; individual layer thicknesses unresolved.

detail-lookout-observation-floor-hole-1153verified · printed

paint-color-relationship

TO BE PAINTED SAME COLOR AS OUTSIDE WALL FINISH

Leader within circular observation floor-hole view. Applies to this depicted circular cover, not all lookout metal. Earlier batch09-a partial NOTPAINT reading is a separate retained audit record whose locator/target still requires reconciliation; this is not a blanket supersession.

IMG_1153 · Locate on drawing ↗

Drawing notation: TO BE PAINTED SAME COLOR AS OUTSIDE WALL FINISH

Leader within circular observation floor-hole view. Applies to this depicted circular cover, not all lookout metal. Earlier batch09-a partial NOTPAINT reading is a separate retained audit record whose locator/target still requires reconciliation; this is not a blanket supersession.

Conflicting readings: parallel-img1153-m013

parallel-img1153-assemblyverified · printed

hanger-bottom-one-piece

BOTTOM 4 SIDES OF HANGERS TO BE IN ONE PIECE

Construction-section note governing depicted hanger bottom. Literal 4 is preserved as side-description text, not installed hanger count or an added drawing inventory.

IMG_1153 · Locate on drawing ↗

Drawing notation: BOTTOM 4 SIDES OF HANGERS TO BE IN ONE PIECE

Construction-section note governing depicted hanger bottom. Literal 4 is preserved as side-description text, not installed hanger count or an added drawing inventory.

parallel-img1153-assemblyunreviewed · printed

hanger-flat-thickness-unresolved

Unresolved

Numeric value unresolved

Local hanger size notation above one-piece note; fine thickness fraction requires targeted high-resolution review.

IMG_1153 · Locate on drawing ↗

Local hanger size notation above one-piece note; fine thickness fraction requires targeted high-resolution review.

lookoutsanitary1014q-1153-hangerverified · printed

hanger-flat-thickness

2½" × 3/16" HANGERS

0.1875 in

Same hanger-size note above bottom/four-sides one-piece clause; flat-stock thickness only.

IMG_1153 · Locate on drawing ↗

Drawing notation: 2½" × 3/16" HANGERS

Same hanger-size note above bottom/four-sides one-piece clause; flat-stock thickness only.

lookoutsanitary1014q-1153-hangerverified · printed

hanger-flat-width

2½" × 3/16" HANGERS

2.5 in

Stock width from same printed size note; no hanger overall height or installed count.

IMG_1153 · Locate on drawing ↗

Drawing notation: 2½" × 3/16" HANGERS

Stock width from same printed size note; no hanger overall height or installed count.

detail-lookout-observation-unit-1153verified · printed

slot-frame-glazing

HINGED FRAMES WITH GLASS PANELS TO BE USED AT ALL SLOT OPENINGS

Printed note applies to slot-opening frames only; hardware designation, glass thickness and quantity unspecified.

IMG_1153 · Locate on drawing ↗

Drawing notation: HINGED FRAMES WITH GLASS PANELS TO BE USED AT ALL SLOT OPENINGS

Printed note applies to slot-opening frames only; hardware designation, glass thickness and quantity unspecified.

detail-lookout-observation-unit-1153verified · printed

horizontal-rod-size

1/2" ⌀ HORIZONTAL RODS

0.5 in

Printed diameter of rods in typical gallery plan; not an installed rod count or spacing.

IMG_1153 · Locate on drawing ↗

Drawing notation: 1/2" ⌀ HORIZONTAL RODS

Printed diameter of rods in typical gallery plan; not an installed rod count or spacing.