Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
w242-room605-chamber-section-trimillegible · printed
chamber-inset-panel-vertical-witness
6′-6[fraction unresolved]Numeric value unresolved
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed inset panel vertical witness fraction not securely established; value withheld. Distinct from complete section 10′-7½″.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 6′-6[fraction unresolved]
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed inset panel vertical witness fraction not securely established; value withheld. Distinct from complete section 10′-7½″.
w242-room605-chamber-section-trimillegible · printed
chamber-lower-panel-vertical-witness
1′-5[fraction unresolved]Numeric value unresolved
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Lower chamber panel vertical interval fraction not securely established; value withheld. Frame/wall applicability remains local.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 1′-5[fraction unresolved]
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Lower chamber panel vertical interval fraction not securely established; value withheld. Frame/wall applicability remains local.
w242-room605-chamber-section-trimverified · printed
chamber-bottom-base-height
6″6 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 6″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
w242-room605-chamber-section-trimverified · printed
chamber-floor-datum-label
FIN. 6TH FLOORPrinted source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: FIN. 6TH FLOOR
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
parallel-img1177-assemblyverified · printed
sheet_subject
PLAN OF JUDGES CHAMBER & LIBRARY 6TH FLOORSelected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
judges_chamber_elevations
JUDGES CHAMBERSelected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
ante_room
ANTE ROOM ROOM 603Selected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
passage_relation
PASSAGE WAY BETWEEN JUDGES CHAMBERS & ANTE RM & COURT RMSelected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
library_room
LIBRARY 607Selected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
judges_stenographer_room
JUDGES STENO 608Selected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
library_ceiling_plan
HALF OF CEILING PLANSelected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyverified · printed
library_ladder_detail
DETAIL OF LADDER IN LIBRARYSelected legible locator evidence; partial assembly-local scope.
parallel-img1177-assemblyunreviewed · printed
remaining_elevation_plan_dimensions
[room dimension chains, panel/shelf geometry, bookcase sections and ladder hardware unresolved]Numeric value unresolved
Unresolved fine locator evidence; value withheld.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: [room dimension chains, panel/shelf geometry, bookcase sections and ladder hardware unresolved]
Unresolved fine locator evidence; value withheld.
w242-room605-chamber-section-trimverified · printed
chamber_printed_room_number
JUDGES CHAMBER (ROOM 605)605 room
Printed chamber elevation assignment; no dimension transferred into floor geometry.
w242-room605-chamber-section-trimverified · printed
similar_room_reference
ROOM 609 SIMILAR609 room
Similarity reference only; does not prove identical coordinates, dimensions or installation.
w242-room605-chamber-section-trimverified · printed
cornice_carving
CARVED WOODSection top leader; species not established from this crop.
w242-room605-chamber-section-trimverified · printed
curtain_pocket
CURTAIN POCKETUpper section pocket leader; depth and mechanism unresolved.
w242-room605-chamber-section-trimverified · printed
section_vertical_dimension
10'-7 1/2"127.5 in
Outer section vertical dimension adjacent chamber detail; breaks and datum ownership require review before interpreting as room ceiling height.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 10'-7 1/2"
Outer section vertical dimension adjacent chamber detail; breaks and datum ownership require review before interpreting as room ceiling height.
detail-courts-20261010-img1177-assemblyverified · printed
library_default_wood
ALL WOOD TO BE OAK EXCEPT JUDGES CHAMBER, OR AS NOTED OR SPECIFIEDBottom general note governing this sheet; cherry exception remains separate and default cannot override leaders.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: ALL WOOD TO BE OAK EXCEPT JUDGES CHAMBER, OR AS NOTED OR SPECIFIED
Bottom general note governing this sheet; cherry exception remains separate and default cannot override leaders.
detail-courts-20261010-img1177-assemblyverified · printed
library_floor_square_size
12" SQUARES WITH 6" BORDER12 in
Bottom sheet floor note: rubber-tile square side only, not room plan geometry.
detail-courts-20261010-img1177-assemblyverified · printed
library_floor_border_width
6" BORDER6 in
Same general floor note, border strip width; extents/turns unresolved.
detail-courts-20261010-img1177-assemblyunreviewed · observed
library_ladder_review_relationship
[library ladder duplicated in IMG_1280 prior package; remaining roller/end-stop/track endpoints not extracted here]Do not duplicate verified IMG_1280 tread and track properties; cross-photo registration remains pending.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: [library ladder duplicated in IMG_1280 prior package; remaining roller/end-stop/track endpoints not extracted here]
Do not duplicate verified IMG_1280 tread and track properties; cross-photo registration remains pending.
chamber-20261012t-library607-ladderverified · printed
seventh_floor_ladder_companion_reference
SAME LADDER IN LIBRARY OF CIRCUIT COURT OF APPEALS 7TH FLOORExplicit companion reuse note for the depicted Library607 ladder type; seventh-floor library relationship only, not proof of an installed ladder count or matching track endpoints.
IMG_1177 · Locate on drawing ↗Drawing notation: SAME LADDER IN LIBRARY OF CIRCUIT COURT OF APPEALS 7TH FLOOR
Explicit companion reuse note for the depicted Library607 ladder type; seventh-floor library relationship only, not proof of an installed ladder count or matching track endpoints.
Calculated from: detail-courts-20261010-img1177-m004
w242-room605-chamber-section-trimverified · printed
chamber_section_column_pocket
COLUMN POCKETCaption beside chamber section pocket, distinct from existing curtain-pocket caption. Pocket extent/profile and installed location need section/plan reconciliation.
IMG_1177 · Locate on drawing ↗Drawing notation: COLUMN POCKET
Caption beside chamber section pocket, distinct from existing curtain-pocket caption. Pocket extent/profile and installed location need section/plan reconciliation.