Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1325 · Folder 186

Typ. Floor

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial catalogue/OCR-first then sequential <=1000px JPEG65 locator review of public/archive/drawings/complete-upright/IMG_1325.webp. IMG_1322 additionally has one 250x435 post-schedule crop. Regions normalized in unrotated access-image coordinates; rotationDegrees is clockwise correction. Selected evidence only, no full extraction/modeling. Partial timed visual review: Additive partial high-resolution access-derivative crop review following batch13-b; original printed evidence only unless explicitly marked OCR conflict. Not full image extraction. Source is 2200x1650 upright access derivative, not master; crop has no resampling or rotation. Partial timed visual review: Prior-package and OCR audit only; no new image inspection or duplicate verified readings. Partial timed visual review: Text/OCR and prior-package audit only; no new image inspection and no duplicate verified measurements. Partial timed visual review: Prior evidence reused; only selected remaining source-local regions reviewed. No historical placement or accepted physical geometry. Partial timed visual review: undefined Partial timed visual review: Source-local schedule, fabrication or connection evidence only; no installed geometry or architectural acceptance. Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • partial locator coverage; remaining individual beam/member sizes, schedules, fine fractions and dimensions outstanding
  • all notes, revisions, symbols, utility legends and companion details require reconciliation
  • historical instance locations, material grades, connection capacities and modeling checks missing
  • Uncropped sheet regions, revisions and title-block detail not reviewed in closeout.
  • All unreadable fractions, individual connection plates/angles/rivets, material grades and instance placement remain outstanding.
  • No master-resolution comparison; access derivative limits fine-text evidence.
  • Remaining member, reinforcement and connection dimensions require fine-region review
  • Revision marks and historical instance placements remain unreconciled
  • Companion-sheet registration and modeling checks remain outstanding
  • Complete fine-fraction/member schedule transcription
  • Historical instance mapping and endpoint registration
  • Annotated revisions and companion notes reconciliation
  • Accepted connections and modeling checks
  • Complete member/plate/bar fraction transcription
  • Historical instance and source-to-plan registration
  • Revision authority and companion applicability
  • Connection and modeling acceptance checks
  • ALL RIVETS note prints CSK head treatment and no diameter in the reviewed clause; prior head-treatment reading reused.
  • Remaining frame members and wall omission clause require different regions.
  • Complete source-to-instance registration, physical endpoints, installed quantities and revision authority remain unresolved.
  • Unreviewed regions, companion sheets, schedules and fine fractions remain open; this package is not exhaustive coverage.
  • Material grades, connection capacities, world transforms and independent model/as-built checks remain unestablished.
  • Complete source-to-plan registration and installed-instance applicability remain unresolved.
  • Unreviewed sheet regions, notes, callouts, schedules and revision authority remain open.
  • Material grades, full profiles, connection capacities and independent modeling checks unresolved.
  • Column numbers4 and93 opposite-hand resolve via existing verified source-local note; installed instance rotations and floor-by-floor mapping remain unresolved.
  • ALL RIVETS diameter remains unknown; head treatment CSK is not a diameter.
  • Complete source-to-instance and endpoint registration remains unresolved.
  • Material grades, finishes, connection capacities and as-built checks remain unestablished.
  • Unreviewed regions, fine fractions, schedules, companion applicability and revision authority remain open.
  • Right-frame clause is DETAILS NOT SHOWN SAME AS TYPICAL FRAME; it is not a wall omission rule.
  • Clause does not establish all matching frame members or connection sizes. Rivet head-treatment note does not establish rivet diameter.
  • Full source-to-instance assignment, physical endpoints, installed quantities and governing revision remain unresolved.
  • Unreviewed regions, notes, fine fractions and companion sheets remain open; this package is not exhaustive coverage.
  • No world geometry, material grade, structural capacity or model acceptance established.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

30 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1325-pilasterverified · printed

assignment

DETAILS OF PILASTER FRAME CONNECTIONS

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: DETAILS OF PILASTER FRAME CONNECTIONS

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterverified · printed

typical

TYPICAL PILASTER FRAME

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: TYPICAL PILASTER FRAME

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterverified · printed

floor_connection

CONNECTION AT FLOOR LEVELS

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: CONNECTION AT FLOOR LEVELS

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterverified · printed

third_floor_connection

CONNECTION AT 3RD FLOOR

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: CONNECTION AT 3RD FLOOR

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterunreviewed · printed

opposite_hand

[columns unresolved] OPP HAND

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: [columns unresolved] OPP HAND

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterunreviewed · printed

sizes

Unresolved

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-anchorverified · printed

assignment

BRICK ANCHOR

Selected visible source evidence only; partial review, applies to depicted assembly.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: BRICK ANCHOR

Selected visible source evidence only; partial review, applies to depicted assembly.

parallel-img1325-pilasterverified · printed

frame_column_assignment

FRAME AT COLS 9 & 88; 4 & 93 OPP HAND

Original printed crop evidence; no annotation substituted. Crop reading conflicts with OCR 9x68 and 6&93; preserve firstpass uncertainty rather than silently overwrite.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: FRAME AT COLS 9 & 88; 4 & 93 OPP HAND

Original printed crop evidence; no annotation substituted. Crop reading conflicts with OCR 9x68 and 6&93; preserve firstpass uncertainty rather than silently overwrite.

parallel-img1325-pilasterverified · printed

angle_column_assignment

L AT COLS 84-13-24-73-11-86 & 95

Original printed crop evidence; no annotation substituted.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: L AT COLS 84-13-24-73-11-86 & 95

Original printed crop evidence; no annotation substituted.

parallel-img1325-pilasterverified · printed

special_frame_column_assignment

SPECIAL FRAME AT COLS 27-37-43-53-36-42-52 & 58

Original printed crop evidence; no annotation substituted.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: SPECIAL FRAME AT COLS 27-37-43-53-36-42-52 & 58

Original printed crop evidence; no annotation substituted.

parallel-img1325-pilasterverified · printed

corner_assignment

L AT CORNER COLS.

Original printed crop evidence; no annotation substituted.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: L AT CORNER COLS.

Original printed crop evidence; no annotation substituted.

parallel-img1325-pilasterverified · printed

truss_support_note

AT COL. 33 CARRIED ON TRUSS 'A'. ALL OTHERS EXTENDED TO COL. BASE.

Original printed crop evidence; no annotation substituted. This is frame support text, not an eccentric baseplate type E′ assignment.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: AT COL. 33 CARRIED ON TRUSS 'A'. ALL OTHERS EXTENDED TO COL. BASE.

Original printed crop evidence; no annotation substituted. This is frame support text, not an eccentric baseplate type E′ assignment.

parallel-img1325-pilasterverified · printed

bracket_support_note

CARRY ON BRACKET FROM COL 2.

Original printed crop evidence; no annotation substituted.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: CARRY ON BRACKET FROM COL 2.

Original printed crop evidence; no annotation substituted.

parallel-img1325-pilasterverified · printed

third_to_fourth_floor_spacing

11′-6″

138 in

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 11′-6″

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

parallel-img1325-pilasterverified · printed

fourth_to_fifth_floor_spacing

11′-6″

138 in

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 11′-6″

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

parallel-img1325-pilasterverified · printed

fifth_to_sixth_floor_spacing

11′-6″

138 in

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 11′-6″

Original printed crop evidence; no annotation substituted. Spacing of depicted typical pilaster frame only.

parallel-img1325-pilasterverified · printed

top_connection_beam_section

9″ I @ 21.0

Original printed crop evidence; no annotation substituted. Separate section specification, not geometric room dimension.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 9″ I @ 21.0

Original printed crop evidence; no annotation substituted. Separate section specification, not geometric room dimension.

parallel-img1325-pilasterverified · printed

base_member_section

12″ I @ 35

Original printed crop evidence; no annotation substituted.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 12″ I @ 35

Original printed crop evidence; no annotation substituted.

parallel-img1325-pilasterunreviewed · printed

all_rivets_diameter

Unresolved

Numeric value unresolved

Original printed crop evidence; no annotation substituted. ALL RIVETS note visible; fraction not confidently read.

IMG_1325 · W-411 · Locate on drawing ↗

Original printed crop evidence; no annotation substituted. ALL RIVETS note visible; fraction not confidently read.

parallel-img1325-pilasterverified · printed

rivet_head_treatment

ALL RIVETS TO BE CSK ON OUTSIDE FACES OF L FRAME.

CSK means countersunk; this note specifies head treatment, not a rivet diameter. Earlier null diameter record retained.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: ALL RIVETS TO BE CSK ON OUTSIDE FACES OF L FRAME.

CSK means countersunk; this note specifies head treatment, not a rivet diameter. Earlier null diameter record retained.

parallel-img1325-pilasterverified · printed

upper_pilaster_vertical_interval

13′-6″

162 in

Outer left vertical witness in upper pilaster elevation, terminating at 7TH FLOOR EL.173.75. Source-local frame interval only.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 13′-6″

Outer left vertical witness in upper pilaster elevation, terminating at 7TH FLOOR EL.173.75. Source-local frame interval only.

parallel-img1325-pilasterverified · printed

seventh_floor_lower_to_upper_level_difference

2′-0″

24 in

Short vertical witness between two seventh-floor lines, EL.171.75 and EL.173.75; no calculated building datum.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 2′-0″

Short vertical witness between two seventh-floor lines, EL.171.75 and EL.173.75; no calculated building datum.

parallel-img1325-pilasterunresolved · printed

wall_stiffener_omission_condition

WALLS NOT SHOWN FOR STIFFENING FRAMES

Visible rotated note at right frame; wording remains uncertain.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: WALLS NOT SHOWN FOR STIFFENING FRAMES

Visible rotated note at right frame; wording remains uncertain.

parallel-img1325-anchorverified · printed

bar_width

2½ × ¼ BAR

2.5 in

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 2½ × ¼ BAR

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

parallel-img1325-anchorverified · printed

bar_thickness

2½ × ¼ BAR

0.25 in

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 2½ × ¼ BAR

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

parallel-img1325-anchorverified · printed

horizontal_projection

1′-9½″

21.5 in

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 1′-9½″

Brick-anchor illustrated flat/profile or local wall-to-end projection; installed spacing, end hook dimension and finish/material grade unknown.

structsched1013g-img1325-third-floor-plateverified · printed

plate_width

7½ × ½ × 1′-2″ PL

7.5 in

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 7½ × ½ × 1′-2″ PL

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

structsched1013g-img1325-third-floor-plateverified · printed

plate_thickness

7½ × ½ × 1′-2″ PL

0.5 in

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 7½ × ½ × 1′-2″ PL

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

structsched1013g-img1325-third-floor-plateverified · printed

plate_length

7½ × ½ × 1′-2″ PL

14 in

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: 7½ × ½ × 1′-2″ PL

Plate leader in horizontal CONNECTION AT 3RD FLOOR plan/detail only; no whole-frame profile or installed plate count.

parallel-img1325-pilasterverified · printed

right_frame_omitted_details_reference

DETAILS NOT SHOWN SAME AS TYPICAL FRAME.

Same rotated right-frame clause identified by prior uncertain wall-stiffener reading. Native crop rotated90° clockwise for reading; words establish reference to typical-frame details, not wall omission.

IMG_1325 · W-411 · Locate on drawing ↗

Drawing notation: DETAILS NOT SHOWN SAME AS TYPICAL FRAME.

Same rotated right-frame clause identified by prior uncertain wall-stiffener reading. Native crop rotated90° clockwise for reading; words establish reference to typical-frame details, not wall omission.

View all source photographs →