Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_0940 · Folder 194

Between Mailing Vestibull X Work Room

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: First-pass partial review of public/archive/drawings/complete-upright/IMG_0940.webp. Solid-door drawing; printed allocations, materials and selected labels reviewed. Background overlapping sheets are excluded. No floor assignment or modeling; remaining regions require review. Partial timed visual review: Additive partial remaining-region review of complete-upright access derivative. Prior verified readings remain in their packages. No floor inference, geometry approval or full extraction claim. Partial timed visual review: Source-local partial detail evidence only; no installed building geometry, quantity or host placement inferred. Partial timed visual review: undefined

Unresolved extraction work
  • all remaining dimensions, notes and callouts
  • companion sheet reconciliation
  • floor assignment
  • full-sheet completeness review
  • Fine dimension fractions and all untranscribed section dimensions require source-resolution crops.
  • Physical instance and floor/room registration require governing plans.
  • Companion details and revisions require reconciliation; modeling/checking unchecked.
  • Complete fine dimension chains, profiles and notes remain unextracted.
  • Physical floor/room registration, installed instances and companion/revision reconciliation remain unresolved.
  • Modeling and architectural checking remain unchecked.
  • Remaining fine profiles, notes and dimension chains not exhausted.
  • Installed floor/room/object registration, companion and revision applicability unresolved.
  • Partial extraction; modeling/checking not performed; authoring excluded.
  • Base-lettering timber-grade suffix and companion-reference question m012 remain open independently of overlaid EXACTLY width.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

19 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img0940-platform-vestibule-doorsverified · printed

required_pair_count

3 pair req.

3 pairs

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: 3 pair req.

Direct printed evidence; partial review.

parallel-img0940-platform-vestibule-transomsverified · printed

required_quantity

3 transoms

3 transoms

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: 3 transoms

Direct printed evidence; partial review.

parallel-img0940-mailing-workroom-doorsverified · printed

required_pair_count

3 pair req.

3 pairs

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: 3 pair req.

Direct printed evidence; partial review.

parallel-img0940-platform-vestibule-doorsverified · printed

location

Between mailing platform x vestibule

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Between mailing platform x vestibule

Direct printed evidence; partial review.

parallel-img0940-mailing-workroom-doorsverified · printed

location

Between mailing vestibule x work room

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Between mailing vestibule x work room

Direct printed evidence; partial review.

parallel-img0940-door-specverified · printed

timber_material

All vertical grain Douglas Fir

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: All vertical grain Douglas Fir

Direct printed evidence; partial review.

parallel-img0940-door-specunreviewed · printed

grade_requirement_unresolved

A Grade ... [remaining wording unclear]

Timber grade suffix remains unreadable.

IMG_0940 · Locate on drawing ↗

Drawing notation: A Grade ... [remaining wording unclear]

Timber grade suffix remains unreadable.

parallel-img0940-platform-vestibule-doorsverified · printed

construction

Solid V.G. Fir

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Solid V.G. Fir

Direct printed evidence; partial review.

parallel-img0940-mailing-workroom-doorsverified · printed

construction

Solid V.G. Fir

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Solid V.G. Fir

Direct printed evidence; partial review.

parallel-img0940-platform-vestibule-doorsverified · printed

flush_panel_requirement

Flush panels

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Flush panels

Direct printed evidence; partial review.

parallel-img0940-mailing-workroom-doorsverified · printed

flush_panel_requirement

Flush panels

Direct printed evidence; partial review.

IMG_0940 · Locate on drawing ↗

Drawing notation: Flush panels

Direct printed evidence; partial review.

parallel-img0940-door-specunreviewed · printed

metal_jamb_reference

Steel jambs see ... [reference unresolved]

Explicit reference noted; identifying drawing mark unresolved.

IMG_0940 · Locate on drawing ↗

Drawing notation: Steel jambs see ... [reference unresolved]

Explicit reference noted; identifying drawing mark unresolved.

parallel-img0940-platform-vestibule-doorsverified · printed

upper_panel_height

1'-7½"

19.5 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 1'-7½"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-platform-vestibule-doorsverified · printed

stile_width

9"

9 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 9"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-platform-vestibule-doorsverified · printed

bottom_rail_height

18"

18 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 18"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-mailing-workroom-doorsverified · printed

upper_panel_height

2'-7"

31 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 2'-7"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-mailing-workroom-doorsverified · printed

upper_rail_height

9"

9 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 9"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-mailing-workroom-doorsverified · printed

intermediate_rail_height

6"

6 in

Direct source notation, applies only to depicted detail; no building geometry inference.

IMG_0940 · Locate on drawing ↗

Drawing notation: 6"

Direct source notation, applies only to depicted detail; no building geometry inference.

parallel-img0940-platform-vestibule-doorsverified · printed

steel_jamb_annotation_width

STEEL JAMBS ARE 6'-4" EXACTLY

76 in

Separate overlaid width annotation with EXACTLY qualifier; neither identifies a companion reference nor selects governing issue.

IMG_0940 · Locate on drawing ↗

Drawing notation: STEEL JAMBS ARE 6'-4" EXACTLY

Separate overlaid width annotation with EXACTLY qualifier; neither identifies a companion reference nor selects governing issue.

View all source photographs →