Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1067 · Folder 191

Plan At Corner 3Rd Floor

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial sequential visual review after catalogue and OCR using 1000px quality65 JPEG locator derived from public/archive/drawings/complete-upright/IMG_1067.webp. Access image lettering is upright. Normalized regions reference original access image. No modeling or exact geometry inferred. Partial timed visual review: Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established. Partial timed visual review: Printed corner-construction note reading only; no corner plan or elevation reconstructed. Partial timed visual review: Bounded target crop inspection; source-local printed/observed evidence only. Partial timed visual review: undefined Partial timed visual review: undefined

Unresolved extraction work
  • full-sheet completeness
  • all remaining fine dimensions, notes, schedules and callouts
  • floor and instance registration
  • Remaining small dimensions, fractions, witness endpoints and section profiles need high-resolution crops
  • Companion drawings and revisions must be reconciled; physical instance/floor registration outstanding
  • Modeling and whole-building acceptance checks not performed
  • Full fine W203 extraction and installed corner/section registration
  • Classified finished/rough/masonry/frame witness endpoints and installation registration remain unresolved.
  • Companion drawings, original/revision authority and as-built applicability remain unresolved.
  • Complete remaining notes, courses, profiles, opening construction and whole-source/model acceptance remain outstanding.
  • Complete remaining regions, fine fractions, notes, schedules and companion details.
  • Classified finished/rough/masonry/frame witness endpoints, original/revision authority and installed correspondence.
  • Physical registration, installed quantities and whole-building/model acceptance remain open.
  • All remaining fine dimensions, notes and companion/revision questions require review.
  • Finished/rough/masonry/frame witness classification, installed correspondence and accepted geometry remain unresolved.
  • Wainscot room clause and screed instruction remain unreadable; remaining jamb dimensions, material boundaries and first-floor applicability need review.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

26 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1067-assemblyverified · printed

sheet_subject

DETAILS OF LOWER STORIES BROADWAY ELEVATION

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: DETAILS OF LOWER STORIES BROADWAY ELEVATION

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

third_floor_corner_plan

PLAN AT CORNER 3RD FLOOR

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: PLAN AT CORNER 3RD FLOOR

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

second_floor_corner_plan

PLAN AT CORNER 2ND FLOOR

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: PLAN AT CORNER 2ND FLOOR

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

first_floor_corner_plan

PLAN AT CORNER 1ST FLOOR

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: PLAN AT CORNER 1ST FLOOR

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

first_floor_sash_jamb_section

SECTION THRU JAMB 1ST FL SASH

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: SECTION THRU JAMB 1ST FL SASH

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

section_reference

SECTION A-A

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: SECTION A-A

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

first_floor_finish_line

LINE OF FIN. 1ST FL.

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: LINE OF FIN. 1ST FL.

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyverified · printed

second_floor_finish_line

LINE OF FIN. 2ND FL.

Selected visually read evidence; partial assembly-local extraction.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: LINE OF FIN. 2ND FL.

Selected visually read evidence; partial assembly-local extraction.

parallel-img1067-assemblyunreviewed · printed

dimensions_unresolved

[stone courses, sash dimensions, corner chains and section elevations too small to verify]

Numeric value unresolved

Uncertain or unreadable detail; value withheld; further review required.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: [stone courses, sash dimensions, corner chains and section elevations too small to verify]

Uncertain or unreadable detail; value withheld; further review required.

parallel-img1067-assemblyverified · printed

first-floor-corner-vault-use

VAULT IN STAMP DEPT.

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: VAULT IN STAMP DEPT.

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyunreviewed · printed

first-floor-corner-concrete-derivation-note

CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE DETAILED ON CORNERS AT A POINT 9'-8" FROM THE INTERSECTION; VOID BEHIND STONE WORK TO BE FILLED WITH BATS [last words require crop]

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE DETAILED ON CORNERS AT A POINT 9'-8" FROM THE INTERSECTION; VOID BEHIND STONE WORK TO BE FILLED WITH BATS [last words require crop]

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyverified · printed

second-floor-elevation-sash-material

STEEL SASH

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: STEEL SASH

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyverified · printed

second-floor-elevation-glazing

PL. GLASS

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: PL. GLASS

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyverified · printed

first-floor-section-waterproofing

MEMBRANE WATERPROOFING

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: MEMBRANE WATERPROOFING

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyverified · printed

first-floor-section-flashing

LEAD FLASHING & COUNTER FLASHING

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: LEAD FLASHING & COUNTER FLASHING

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

parallel-img1067-assemblyverified · printed

third-floor-reference-line

LINE OF 3RD FL.

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: LINE OF 3RD FL.

Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.

rails1012i-img1067-corner-noteverified · printed

basement_corner_bevel_and_fill_note

NOTE: CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE BEVELED ON CORNERS AT A POINT 4'-5" FROM THE INTERSECTION. VOID BEHIND STONE-WORK TO BE FILLED WITH BATS.

Targeted crop directly reads beveled, 4'-5 and bats; resolves prior unreviewed detailed/9'-8 candidate without deleting it.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: NOTE: CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE BEVELED ON CORNERS AT A POINT 4'-5" FROM THE INTERSECTION. VOID BEHIND STONE-WORK TO BE FILLED WITH BATS.

Targeted crop directly reads beveled, 4'-5 and bats; resolves prior unreviewed detailed/9'-8 candidate without deleting it.

rails1012i-img1067-corner-noteverified · printed

printed_corner_bevel_offset_from_intersection

4'-5" FROM THE INTERSECTION

53 in

Printed offset within construction note, not a traced coordinate. Which theoretical/physical intersection and concrete faces require plan witness review.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: 4'-5" FROM THE INTERSECTION

Printed offset within construction note, not a traced coordinate. Which theoretical/physical intersection and concrete faces require plan witness review.

exterior1014a-img1067-stone-course-witnessverified · printed

same_image_stone_course_dimension_convention

NOTE: DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONE AND INCLUDE A ¼″ JOINT.

Independently visible course note on this image; no cross-image substitution of a note or installed corner registration.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: NOTE: DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONE AND INCLUDE A ¼″ JOINT.

Independently visible course note on this image; no cross-image substitution of a note or installed corner registration.

exterior1014a-img1067-stone-course-witnessverified · printed

selected_upper_course_bottom_to_bottom_height

2′-0″

24 in

Selected vertical 2'-0 token in left course chain beside second-story sash; bottom-to-bottom convention explicitly includes 1/4-inch joint. Other chain cells/fractions remain separate; no full course inventory or historic world elevation.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: 2′-0″

Selected vertical 2'-0 token in left course chain beside second-story sash; bottom-to-bottom convention explicitly includes 1/4-inch joint. Other chain cells/fractions remain separate; no full course inventory or historic world elevation.

Calculated from: exterior1014a-img1067-course-note

parallel-img1067-assemblyverified · printed

selected_first_to_second_floor_local_stone_course_height

2′-0″

24 in

One repeated local course witness in first-to-second-floor elevation chain, selected beside the mid-height lower stone block. Course/joint convention already verified separately. No installed count or complete course schedule.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: 2′-0″

One repeated local course witness in first-to-second-floor elevation chain, selected beside the mid-height lower stone block. Course/joint convention already verified separately. No installed count or complete course schedule.

parallel-img1067-assemblyillegible · printed

cornice_and_spacer_fractional_dimensions

Unresolved

Numeric value unresolved

Small spacer and first-floor cornice profile fractions not securely read in this bounded crop; neighboring 2′-0″ courses cannot supply them.

IMG_1067 · W-203 · Locate on drawing ↗

Small spacer and first-floor cornice profile fractions not securely read in this bounded crop; neighboring 2′-0″ courses cannot supply them.

parallel-img1067-assemblyverified · printed

first_floor_jamb_stool_alternative_material

MARBLE OR WOOD STOOL AS REQUIRED

Printed material alternatives for stool in first-floor sash jamb section; does not select installed marble/wood, finish, thickness or room applicability.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: MARBLE OR WOOD STOOL AS REQUIRED

Printed material alternatives for stool in first-floor sash jamb section; does not select installed marble/wood, finish, thickness or room applicability.

parallel-img1067-assemblyverified · printed

first_floor_jamb_grille_designation

GRILLE

Leader identifies grille within jamb-section/window-side zone. No bar size, count, material or installed grille quantity.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: GRILLE

Leader identifies grille within jamb-section/window-side zone. No bar size, count, material or installed grille quantity.

parallel-img1067-assemblyverified · printed

first_floor_jamb_to_window_center_local_span

3′-9″

45 in

Local horizontal term below section between left jamb-side witness and window center reference. Exact rough/finished face classification and opening width remain open.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: 3′-9″

Local horizontal term below section between left jamb-side witness and window center reference. Exact rough/finished face classification and opening width remain open.

parallel-img1067-assemblyillegible · printed

first_floor_jamb_wainscot_room_clause

WOOD WAINSCOT IN [room text unresolved]

WOOD WAINSCOT is readable but room wording and adjacent lower screed instruction are not secure at native crop; preserve entire clause unresolved without room assignment.

IMG_1067 · W-203 · Locate on drawing ↗

Drawing notation: WOOD WAINSCOT IN [room text unresolved]

WOOD WAINSCOT is readable but room wording and adjacent lower screed instruction are not secure at native crop; preserve entire clause unresolved without room assignment.

View all source photographs →