Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1135-detailverified · printed
elevator_mark
Details of Elevator No.33 number
Partial source detail only; no world placement or complete geometry established.
parallel-img1135-detailverified · printed
machine_room_view
Machine room plan — Elevator No.3Partial source detail only; no world placement or complete geometry established.
parallel-img1135-detailverified · printed
sheave_landing_view
Plan of sheave service landingPartial source detail only; no world placement or complete geometry established.
parallel-img1135-detailverified · observed
floor_plan_views
Basement, 1st and 2nd floor plansPartial source detail only; no world placement or complete geometry established.
parallel-img1135-detailverified · printed
shaft_sections
SECTION A-A; SECTION B-BPartial source detail only; no world placement or complete geometry established.
parallel-img1135-detailverified · printed
dumbwaiter_system
Electric dumbwaiter for Stamp Dept.Partial source detail only; no world placement or complete geometry established.
parallel-img1135-detailunreviewed · observed
fine_dimensions
Shaft size, machine/sheave layout, equipment capacity, pit/overhead levels and structural sections unresolvedNumeric value unresolved
Partial source detail only; no world placement or complete geometry established.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: Shaft size, machine/sheave layout, equipment capacity, pit/overhead levels and structural sections unresolved
Partial source detail only; no world placement or complete geometry established.
detail-1135-air-intakeverified · printed
duct_function
FRESH AIR INTAKESection B-B intake annotation; dimensions and duct material pending.
detail-fittings-1135-machinefinishverified · printed
machine-room-finish
ACOUSTICAL TREATMENT ON WALLS & CEILINGSource-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: ACOUSTICAL TREATMENT ON WALLS & CEILING
Source-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
detail-fittings-1135-machinefinishverified · printed
machine-room-access-steps
CONC. STEPSSource-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: CONC. STEPS
Source-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
detail-fittings-1135-machinefinishverified · printed
elevator-lobby-directory-board
DIRECTORY BOARDSource-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: DIRECTORY BOARD
Source-local detail only; no installed quantity, floor geometry or accepted model placement. Printed floor/room assignment preserved separately.
elevator1013p-w231-section-aa-lobby-finish-zoneverified · printed
lobby_upper_finish_plaster_cornice
PLASTER CORNICELeader names cornice in adjacent lobby portion of section A-A between first- and second-floor reference bands; no room number, profile, length or thickness established.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: PLASTER CORNICE
Leader names cornice in adjacent lobby portion of section A-A between first- and second-floor reference bands; no room number, profile, length or thickness established.
elevator1013p-w231-section-aa-lobby-finish-zoneverified · printed
lobby_upper_wall_finish
PLASTER WALLSPrinted finish for the lobby-side wall zone beside shaft, not a blanket shaft-wall material assignment.
elevator1013p-w231-section-aa-lobby-finish-zoneverified · printed
lobby_lower_wall_finish
STAINLESS STEEL WAINSCOTLeader identifies lower wall finish within first-floor lobby-side zone. Gauge, finish process, height and extents not established.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: STAINLESS STEEL WAINSCOT
Leader identifies lower wall finish within first-floor lobby-side zone. Gauge, finish process, height and extents not established.
parallel-img1135-detailverified · printed
foundation_structural_companion_note
NOTE SEE STRUCTURAL DRAWINGS FOR FOUNDATIONSeparate source instruction for foundation coordination; source does not itself supply an accepted pit foundation profile.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: NOTE SEE STRUCTURAL DRAWINGS FOR FOUNDATION
Separate source instruction for foundation coordination; source does not itself supply an accepted pit foundation profile.
stairs1014y-1135-landingverified · printed
service_landing_horizontal_clear_hatch_below_witness
8′-0″ CLEAR HATCH BELOW96 in
Horizontal hatch-below dimension across the right portion of the sheave-service-landing plan; not the outer landing width. Source-local only; no installed geometry or historical issue selected.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: 8′-0″ CLEAR HATCH BELOW
Horizontal hatch-below dimension across the right portion of the sheave-service-landing plan; not the outer landing width. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1135-landingverified · printed
service_landing_left_strip_horizontal_witness
4′-6″54 in
Horizontal witness across left strip of landing beside the drawn trap; endpoints remain source-local. Source-local only; no installed geometry or historical issue selected.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: 4′-6″
Horizontal witness across left strip of landing beside the drawn trap; endpoints remain source-local. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1135-accessverified · printed
machine_room_access_end_wall_material
CONC. END WALLSLeader names concrete end walls at machine-room access; no thickness or reinforcement inferred. Source-local only; no installed geometry or historical issue selected.
IMG_1135 · W-231 · Locate on drawing ↗Drawing notation: CONC. END WALLS
Leader names concrete end walls at machine-room access; no thickness or reinforcement inferred. Source-local only; no installed geometry or historical issue selected.