Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_0899 · Folder 195

DISTRICT COURT ROOM BALUSTRADES

Sheet Shop Drawing 68

Extraction: Reviewed · extraction partial. full photographed field; upper overlaid baluster part strip; main part studies and sectional build-ups; joint-orientation note; balustrade elevation and plan chains; Room 602/612 labels; white-oak/finish note; approval notation and title block; visible background note for applicability exclusion Partial timed visual review: Targeted source-local review only; bounds broadly locate the inspected source field. Partial timed visual review: undefined Partial timed visual review: Bounded source review; prior readings reused, every new property source-local and authoring-ineligible. No whole-image completion or installed quantity established. Partial timed visual review: Text-only reuse of courtroom-602-img0899-balustrade-detail. Rotation is inherited master transform, not newly verified access derivative rotation. Partial timed visual review: Bounded source reinspection; prior verified measurements reused without duplicating them. No completion or geometry claim. Partial timed visual review: undefined

Unresolved extraction work
  • Target linework hidden beneath folds or overlaid paper cannot be reviewed from this photograph.
  • Several faint dimension strings and endpoints remain unreadable.
  • Drawing scale, architectural sheet number and complete issue/revision chain are not legible.
  • No companion image was visually opened in this bounded extraction.
  • Room 602/612 base-face controls
  • part-to-joint map
  • gate and count controls
  • Sheet 238
  • Both between-base-face numbers illegible in selected master strip
  • Gate fractions and clear endpoints
  • Overlay/fold-hidden fabrication regions
  • Installed instance allocation and accepted source-to-building transform
  • Complete construction profiles, joinery and governing revision
  • Whole-region exhaustive extraction not certified
  • Room602 and612 between-base-face numerals remain illegible
  • Gate clear width, thickness applicability, hardware and swing
  • Rail/post/baluster complete profiles and part-to-joint map
  • Installed counts and registered run endpoints
  • Fold/overlay-hidden regions require unobscured companion
  • Gate/hardware and complete installed counts
  • Profile sections
  • Placement
  • Whole-region completion
  • Room 602/612 between-base-face controls
  • Part and joinery ownership
  • Fold/overlay-hidden linework
  • Sheet 238 crosswalk
  • Installed instance allocation and world registration
  • Complete fine dimensions, sections and joinery
  • Companion references and review disposition
  • Accepted historical revision and physical installed instance allocation
  • Complete member profiles, hardware templates, fasteners and joinery
  • Companion details, floor/room crosswalk and source-to-building registration

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

37 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f6-court602-w257-wood-balustradeverified · printed

exposed_wood_material

ALL FINE GRAIN PLAIN WHITE OAK

Material identity only; no grain direction or board grade is inferred beyond the note. Authoring eligible: true. Source audit state: verified.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: ALL FINE GRAIN PLAIN WHITE OAK

f6-court602-w257-wood-balustradeverified · printed

finish_process

HAND FILLED WITH PASTE FILLER AND WAX ... [remainder partly unreadable]

Eligible only as qualitative finish intent; coat count, product and sheen remain null. Authoring eligible: true. Source audit state: verified-material/process-terms; sentence-incomplete.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: HAND FILLED WITH PASTE FILLER AND WAX ... [remainder partly unreadable]

f6-court602-w257-wood-balustradeverified · printed

stain_color_control

FINISH — STAIN TO APPROVED COLOR ... [remainder partly unreadable]

The approved sample/color is not present, so no RGB, named stain, or present-day appearance may be inferred. Authoring eligible: false. Source audit state: verified-core-phrase; sentence-incomplete.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: FINISH — STAIN TO APPROVED COLOR ... [remainder partly unreadable]

f6-court602-img0899-balustrade-source-detailverified · observed

distinct_printed_part_marks_observed

1 through 36

36 distinct marks

Authoring eligible: false. Source audit state: verified-mark-set; not-an-installed-quantity.

f6-court602-img0899-baluster-prototype-averified · printed

lamination_or_joint_orientation

PLACE BALS SO JOINTS COME ON INSIDE / JUDGE'S SIDE / FRONT

Local orientation rule only. The source does not supply a world transform or a complete mapping of every marked part to the diagram. Authoring eligible: true. Source audit state: verified-core-instruction.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: PLACE BALS SO JOINTS COME ON INSIDE / JUDGE'S SIDE / FRONT

f6-court602-img0899-part-23verified · printed

local_axial_length

6 1/4"

6.25 in

Applies to the dimensioned mark-23 block in the overlaid part study. The part's final placement/orientation in the Room 602 assembly remains unresolved. Authoring eligible: false. Source audit state: verified-local-endpoints.

f6-court602-img0899-part-21verified · printed

local_axial_length

6 1/4"

6.25 in

Applies to the dimensioned mark-21 side member in the overlaid part study; final assembly placement remains unresolved. Authoring eligible: false. Source audit state: verified-local-endpoints.

f6-court602-img0899-part-22verified · printed

local_axial_length

6 1/4"

6.25 in

Applies to the dimensioned mark-22 side member in the overlaid part study; final assembly placement remains unresolved. Authoring eligible: false. Source audit state: verified-local-endpoints.

f6-court602-img0899-rail-run-prototypeverified · printed

local_section_control

1 7/8"

1.875 in

Local sectional control beside the 1–11 build-up; the owning fabrication interface is not yet named securely. Authoring eligible: false. Source audit state: verified-local-endpoints.

f6-court602-img0899-rail-run-prototypeunreviewed · printed

repeated_plan_bay_control

8'-[inch suffix unreadable]

Four apparent repetitions are visible in the photographed plan chain; this is not an installed bay count and the inch suffix is not secure. Authoring eligible: false. Source audit state: partial-transcription.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: 8'-[inch suffix unreadable]

f6-court602-w257-wood-balustradeverified · printed

distance_between_base_faces

DISTRICT COURT 602 BETWEEN BASE FACES; dimension value unreadable/obscured

Authoring eligible: false. Source audit state: verified-label; unresolved-value.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT 602 BETWEEN BASE FACES; dimension value unreadable/obscured

f6-court612-img0899-balustrade-referenceverified · printed

distance_between_base_faces

DISTRICT COURT 612 BETWEEN BASE FACES; dimension value unreadable/obscured

Authoring eligible: false. Source audit state: verified-label; unresolved-value.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT 612 BETWEEN BASE FACES; dimension value unreadable/obscured

f6-court602-img0899-baluster-prototype-aunreviewed · observed

installed_quantity_room602

Unresolved

The drawing shows typical/analytical work and plan symbols; exact installed count is not printed securely. Authoring eligible: false. Source audit state: explicit-null.

f6-court602-img0899-balustrade-source-detailverified · observed

Physical balustrade geometry gate

FAIL — local component evidence only

Room 602 and Room 612 between-base-faces dimension values are unreadable/obscured. Overall height, complete rail/base sections, exact endpoints, post/baluster spacing, installed quantities, and gate width/swing are unresolved. Several visible dimensions lack defensible endpoints because folds and overlaid sheets cross the linework. The 1–36 shop-part marks are transcribed, but a complete fabrication/joinery map is not verified. IMG_0899 has no world transform and is not registered to W257 or W8. The W257 SEE DETAIL SHEET No. 238 callout is not positively resolved to IMG_0899; Shop Drawing No. 68 is not treated as architectural Sheet 238. No paper-scale or pixel-derived measurements are permitted.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT ROOM BALUSTRADES

Complete photographed field after clockwise rotation to analysis-upright orientation.

f6-court602-img0899-balustrade-source-detailverified · derived

Source-linked analytical local control study permitted

Permitted; not physical geometry or building placement

1 count

IMG_0899 may augment component identity, white-oak/finish intent, the inward joint-orientation rule, shop part marks, and a few local controls. It must not generate or replace Room 602 physical balustrade geometry.

IMG_0899 · shop-drawing-68-IMG0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT ROOM BALUSTRADES

Complete photographed field after clockwise rotation to analysis-upright orientation.

f6-court602-img0899-balustrade-source-detailNumbered parts and local fold interruptions checked; no whole part-to-joint dimension closure established. · observed

fold_interrupted_part_register

[part strips intersect folds and overlapped sheet regions]

Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.

IMG_0899 · Locate on drawing ↗

Drawing notation: [part strips intersect folds and overlapped sheet regions]

Source-local observation/reference only; no dimensions, approval or world geometry inferred beyond stated evidence.

f6-court602-img0899-balustrade-source-detailunreviewed · printed

room602_between_base_faces_targeted_reread

DISTRICT COURT 602 BETWEEN BASE FACES [number obscured]

Numeric value unresolved

Same previously prepared upright master strip reviewed sequentially. Label readable; numerical token remains illegible. No derived run from repeated bays or mirrored Room612 length.

IMG_0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT 602 BETWEEN BASE FACES [number obscured]

Same previously prepared upright master strip reviewed sequentially. Label readable; numerical token remains illegible. No derived run from repeated bays or mirrored Room612 length.

f6-court612-img0899-balustrade-referenceunreviewed · printed

room612_between_base_faces_targeted_reread

DISTRICT COURT 612 BETWEEN BASE FACES [number obscured]

Numeric value unresolved

Independent printed Room612 line; separate from Room602. The selected strip does not supply an accepted run length, installed post/baluster quantity or gate allocation.

IMG_0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT 612 BETWEEN BASE FACES [number obscured]

Independent printed Room612 line; separate from Room602. The selected strip does not supply an accepted run length, installed post/baluster quantity or gate allocation.

f6-court602-img0899-balustrade-source-detailillegible · printed

room602_between_base_faces_followup

DISTRICT COURT 602 BETWEEN BASE FACES [dimension numeral illegible]

Numeric value unresolved

Direct high-resolution plan/title strip verifies label and endpoint class BETWEEN BASE FACES, already established in prior report; numeric room run is still unreadable. The same strip also labels612; no copied length or installed run accepted.

IMG_0899 · Locate on drawing ↗

Drawing notation: DISTRICT COURT 602 BETWEEN BASE FACES [dimension numeral illegible]

Direct high-resolution plan/title strip verifies label and endpoint class BETWEEN BASE FACES, already established in prior report; numeric room run is still unreadable. The same strip also labels612; no copied length or installed run accepted.

View all source photographs →