Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1152 · Folder 191

Lookout

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial locator review after catalogue/OCR using <=1000px JPEG65 derivative of public/archive/drawings/complete-upright/IMG_1152.webp. Lettering upright. Regions are original access-image normalized coordinates. Locating a region does not claim full review of its fine detail. No modeling. Partial timed visual review: Additive bounded remaining-region review of upright WebP after queue, OCR and prior packages; no geometry acceptance. Partial timed visual review: Verified entry finishes and tell-tale records reused; no new source inspection Partial timed visual review: Prior finish/material/fixture text findings reused; source not reopened and no duplicate properties added. Partial timed visual review: Source-local view inventory and selective notes/individual properties; repeated-photo correspondence does not establish revision equivalence, installed quantity or exact geometry. Partial timed visual review: Selected source-local properties; source remains incomplete.

Unresolved extraction work
  • complete review of each region and fine note
  • remaining dimensions, materials, schedules, callouts and revisions
  • floor/object registration and cropped companion evidence
  • Fine fractional dimensions and classified extension endpoints in remaining regions
  • Complete individual component inventory and companion-sheet/revision reconciliation
  • Accepted source-to-building transform and actual installed geometry
  • Remaining regions, fine fractions and extension endpoints need review
  • Installed instance mapping and accepted source-to-building transform
  • Companion details and revision reconciliation
  • No additional source regions visually reviewed in this bounded package
  • Remaining dimensions, fractions, endpoint classification and revision reconciliation
  • Installed instance mapping and governing finish schedules
  • Accepted source-to-building transform and full region extraction remain outstanding
  • Full high-resolution fine-fraction and endpoint review of each inventoried view remains
  • Handwriting, original/revision dates, approved samples and source precedence remain unclosed
  • Companion detail matching and source-to-installed-object / room registration remain
  • Cropped views need corresponding source photographs; missing evidence has not been declared irrecoverable
  • Individual objects retain specific missing properties; no source or floor completed by this inventory
  • Pipe bore, shaft floor heights, complete plate/hinge fixing sizes and installed rail span unresolved.
  • Installed instances, full component dimensions and hardware specifications remain unresolved.
  • Governing revisions, companion details and source-to-building registration remain unresolved.
  • No geometry acceptance or architectural release; all unreviewed source regions remain open.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

19 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1152-assemblyverified · printed

subject

LOOKOUT GALLERYS

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: LOOKOUT GALLERYS

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

section_AA

SECTION A-A

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: SECTION A-A

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

section_BB

SECTION B-B

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: SECTION B-B

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

entrance_second_floor

ENTRANCE TO LOOKOUT GALLERY AT SECOND FLOOR

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: ENTRANCE TO LOOKOUT GALLERY AT SECOND FLOOR

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

tell_tale_offset

TELL-TALES PLACED 2'-0" IN FRONT OF PROJECTION

24 in

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: TELL-TALES PLACED 2'-0" IN FRONT OF PROJECTION

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

guard_rail_material

OAK ROD

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: OAK ROD

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

guard_rail_cushion

RUBBER SLEEVE CUSHION

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: RUBBER SLEEVE CUSHION

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyverified · printed

guard_rail_detail_scale

3" SCALE DETAIL OF LOOKOUT GUARD RAILS

3 in/ft

Selected legible locator evidence; partial assembly-local extraction.

IMG_1152 · Locate on drawing ↗

Drawing notation: 3" SCALE DETAIL OF LOOKOUT GUARD RAILS

Selected legible locator evidence; partial assembly-local extraction.

parallel-img1152-assemblyunreviewed · printed

remaining_dimensions

[oak rod diameter, pipe bore, hinge-pin sizes and shaft floor heights unresolved]

Numeric value unresolved

Uncertain locator reading; value withheld; full detail review outstanding.

IMG_1152 · Locate on drawing ↗

Drawing notation: [oak rod diameter, pipe bore, hinge-pin sizes and shaft floor heights unresolved]

Uncertain locator reading; value withheld; full detail review outstanding.

detail-lookout-secondfloor-entry-1152verified · printed

entry-floor-material

LINOLEUM FLOOR

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1152 · Locate on drawing ↗

Drawing notation: LINOLEUM FLOOR

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-secondfloor-entry-1152verified · printed

entry-base-material

WOOD BASE

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1152 · Locate on drawing ↗

Drawing notation: WOOD BASE

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-secondfloor-entry-1152verified · printed

access-ladder-material

IRON LADDER

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1152 · Locate on drawing ↗

Drawing notation: IRON LADDER

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-telltale-1152verified · printed

cord-spacing-and-ends

CORD 4" O.C. KNOTTED BOTH ENDS

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1152 · Locate on drawing ↗

Drawing notation: CORD 4" O.C. KNOTTED BOTH ENDS

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

detail-lookout-telltale-1152verified · printed

cord-spacing

4" O.C.

4 in

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

IMG_1152 · Locate on drawing ↗

Drawing notation: 4" O.C.

Depicted source-local component only; no installed quantity, room geometry or world placement inferred.

lookoutsanitary1014q-1152-guardrailverified · printed

pin-size

1/4" PIN

0.25 in

Leader identifies small pin; diameter interpretation follows circular pin representation, not all hinge bolts.

IMG_1152 · Locate on drawing ↗

Drawing notation: 1/4" PIN

Leader identifies small pin; diameter interpretation follows circular pin representation, not all hinge bolts.

lookoutsanitary1014q-1152-guardrailverified · printed

oak-rod-size

1½" OAK ROD

1.5 in

Printed rod size; source-local type, no installed rail quantity or span.

IMG_1152 · Locate on drawing ↗

Drawing notation: 1½" OAK ROD

Printed rod size; source-local type, no installed rail quantity or span.

lookoutsanitary1014q-1152-guardrailverified · printed

receiver-projection

3"

3 in

Plan witness from receiver outer end to wall-side reference; not wall thickness.

IMG_1152 · Locate on drawing ↗

Drawing notation: 3"

Plan witness from receiver outer end to wall-side reference; not wall thickness.

lookoutsanitary1014q-1152-guardrailverified · printed

hinge-wall-to-pin-offset

1¾"

1.75 in

Left plan chain interval from wall-side reference to pivot line; no whole rail span.

IMG_1152 · Locate on drawing ↗

Drawing notation: 1¾"

Left plan chain interval from wall-side reference to pivot line; no whole rail span.

lookoutsanitary1014q-1152-guardrailverified · printed

pin-to-sleeve-end-offset

4¼"

4.25 in

Adjacent plan-chain interval from pivot line to sleeve-end line; no total rail span.

IMG_1152 · Locate on drawing ↗

Drawing notation: 4¼"

Adjacent plan-chain interval from pivot line to sleeve-end line; no total rail span.

View all source photographs →