Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1008 · Folder 193

Counterx Gatt

Original sheet identity has not yet been reconciled.

Extraction: Reviewed · extraction partial. Partial timed visual review: Partial first-pass sequential visual review of public/archive/drawings/complete-upright/IMG_1008.webp after catalogue and OCR. Regions are displayed access-image coordinates. No exact room geometry or modeling inference. Partial timed visual review: Bounded source-local shop detail/type evidence. No accepted geometry, complete extraction, installed quantity or inferred floor assignment. Partial timed visual review: undefined Partial timed visual review: Selected local fabrication and note evidence only; prior verified readings reused. Partial timed visual review: Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

Unresolved extraction work
  • all remaining fine notes, dimension chains, revisions and callouts
  • full-sheet completeness
  • floor and instance registration
  • unreviewed: Gate/standard/strip dimensions and remaining complete elevation chains
  • illegible: Fine gate-head and strip fractions not established in crop
  • cropped: Left section crop excludes right note block, full title and long elevation
  • companion: IMG_1009 same-mail-counter companion evidence reused; installed room/floor and wall interface remain open
  • Fine gate-head, standard and strip dimensions remain unreviewed.
  • Installed room/floor, wall interface and delivery occurrence remain unestablished.
  • Complete source-region extraction, installed assignment, governing revision and architectural acceptance remain open.
  • Remaining fine dimension chains and profiles
  • Installed floor/room registration and companion applicability
  • Revision authority and independent checking
  • Unextracted fine dimension chains, moulding profiles and marginal annotations
  • Floor/room and installed instance registration; companion and revision reconciliation
  • Full-region extraction remains incomplete

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

17 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

parallel-img1008-assemblyverified · printed

assembly_label

COUNTER & GATE SUPERINTENDENT OF MAILS OFFICE

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: COUNTER & GATE SUPERINTENDENT OF MAILS OFFICE

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

gate_head_half_span

3'-6¼"

42.25 in

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: 3'-6¼"

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

countertop_material

Counter top Plain White Oak Stained and Shellacked

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: Counter top Plain White Oak Stained and Shellacked

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

countertop_delivery

Counter top to be fitted but sent loose

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: Counter top to be fitted but sent loose

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

panel_preinstallation_finish

Stain and shellac panels before installing

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: Stain and shellac panels before installing

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

gate_section_reference

GATE SECTION

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: GATE SECTION

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

drawing_number

9

9 drawing-number

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: 9

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

order_number

2008

2008 order-number

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: 2008

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyverified · printed

approval_date

5-11-32

Selected visually read printed evidence; partial review; assembly-local scope.

IMG_1008 · Locate on drawing ↗

Drawing notation: 5-11-32

Selected visually read printed evidence; partial review; assembly-local scope.

parallel-img1008-assemblyunreviewed · printed

loose_parts_delivery

Inside standards, M & V ceiling, back casings and base to be sent loose

Unresolved or tentative lettering; numeric reading withheld. Partial source review.

IMG_1008 · Locate on drawing ↗

Drawing notation: Inside standards, M & V ceiling, back casings and base to be sent loose

Unresolved or tentative lettering; numeric reading withheld. Partial source review.

parallel-img1008-assemblyverified · printed

inside_standard_label_and_member_relationship

Inside Standard

Label and leader identify the inside standard beside the tenon section; this is a local member relationship, not proof that delivery occurred or an installed count.

IMG_1008 · Locate on drawing ↗

Drawing notation: Inside Standard

Label and leader identify the inside standard beside the tenon section; this is a local member relationship, not proof that delivery occurred or an installed count.

Calculated from: parallel-img1008-m010

parallel-img1008-assemblyverified · printed

case_return_strip_relationship

Case returns on strip here

Printed note at the case return in the inspected partial elevation identifies a strip relationship. The strip dimensions and material remain unresolved.

IMG_1008 · Locate on drawing ↗

Drawing notation: Case returns on strip here

Printed note at the case return in the inspected partial elevation identifies a strip relationship. The strip dimensions and material remain unresolved.

parallel-img1008-assemblyverified · printed

loose_parts_delivery_clause

Inside standards, M & V Ceiling, Back casings and Base to be sent loose

Full same-image delivery clause. M & V retained literally, without expansion; no installed count or evidence that delivery occurred.

IMG_1008 · Locate on drawing ↗

Drawing notation: Inside standards, M & V Ceiling, Back casings and Base to be sent loose

Full same-image delivery clause. M & V retained literally, without expansion; no installed count or evidence that delivery occurred.

closure1011aa-img1008-assemblyverified · printed

tenon_delivery_instruction

Tenons not cross-hatched to be shipped loose for installation after front and end has been set over wall

Printed upper-left note applies to indicated unhatched tenons. Delivery/assembly sequence only; does not establish installed wall geometry.

IMG_1008 · Locate on drawing ↗

Drawing notation: Tenons not cross-hatched to be shipped loose for installation after front and end has been set over wall

Printed upper-left note applies to indicated unhatched tenons. Delivery/assembly sequence only; does not establish installed wall geometry.

parallel-img1008-assemblyverified · printed

wall-return-annotation

The wall returns on right to front

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

IMG_1008 · Locate on drawing ↗

Drawing notation: The wall returns on right to front

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

parallel-img1008-assemblyverified · printed

wall-reference

Tile Wall

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

IMG_1008 · Locate on drawing ↗

Drawing notation: Tile Wall

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

parallel-img1008-assemblyverified · printed

architect-build-up-note

Note to Architect. This could be built up complete if it were not for the wall involved.

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

IMG_1008 · Locate on drawing ↗

Drawing notation: Note to Architect. This could be built up complete if it were not for the wall involved.

Depicted shop-drawing assembly only; no exact room geometry, installed quantity, historical room assignment or accepted model placement.

View all source photographs →