Gus J. SolomonUnited States Courthouse
← Back to the building1933 reconstruction · research preview

The measured building.

Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.

Source photographs
464
Identified objects
4872
Verified printed values
12046
Disputed values
20

464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.

Download the structured register (JSON)

Open the coordinated research model →

Clear filters
IMG_1214 · Folder 190

FIFTH FLOOR PLAN

Sheet W7

Extraction: Reviewed · extraction partial. Partial companion: Close-up of Main-side rooms, dimensions, title and datum Partial timed visual review: Selected source-local partition witness review; existing room widths and office labels not repeated. Partial timed visual review: Prior verified extraction reused without duplication; selected new properties only. No full-coverage or physical geometry claim. Partial timed visual review: Additional source-local room identity and dimension endpoint review only; no geometry acceptance. Partial timed visual review: undefined Partial timed visual review: undefined Partial timed visual review: Fifth-floor lower facade/title exposure; selected crop missed the attorney interior band. Existing room witnesses/marks reused.

Unresolved extraction work
  • All remaining notes, dimensions and regions
  • Remaining region dimensions and notes
  • Room 522/521/520 spans and exact faces
  • Physical geometry and material assignments
  • Full room/opening/fixture inventory and property extraction
  • Exact witness endpoints, wall faces and closed polygons
  • Companion details, schedules and revision authority
  • Installed quantities, materials and accepted building registration
  • Closed boundary and exact finish/rough/structural face classification
  • Opening size, head/sill level, hardware and schedule correlation
  • Companion details and installed/revised state
  • Accepted source-to-building registration
  • Remaining fine dimensions, notes, schedules and callouts require targeted full-resolution crops
  • Exact finished/rough/structural/clear face classification and closed boundaries
  • Complete local dimension, door/window/type/detail inventory
  • Applicable companion construction, finish exceptions and chronology
  • Checked physical registration and installed quantities
  • Each physical wall/room/opening still needs classified finish/rough/structural faces, closed boundaries, build-up, levels, installed quantity and checked building registration; source glyph closure does not supply these.
  • Exact finished/rough/structural/clear endpoint classes, closed boundaries and physical dimensions remain unresolved.
  • Installed quantities, construction build-up, fixture/material schedules, original/revision authority and companion applicability remain unresolved.
  • Source-to-building registration, datum continuity, independent checks and architectural acceptance remain unaccepted.
  • All remaining unreviewed notes, regions, callouts and schedules require further review.

Download OCR observations (unverified)

Loading the selected drawing…

Scroll or pinch to inspect this drawing. Archival drawing photograph · Oregon Historical Society research collections.

Open source image separately ↗

27 matching properties

Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.

f5-main-wall-witness-controlverified · printed

overall_wall_witness_span

160′10″

160.833333 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 160′10″

Individually recorded property; no unprinted scope/geometry inferred.

floor-5verified · printed

finish_floor_elevation

FIN. FL. ELEV. 148.75

148.75 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: FIN. FL. ELEV. 148.75

Individually recorded property; no unprinted scope/geometry inferred.

f5-corridor-attorneyverified · printed

local_furred_ceiling_height

THIS CORRIDOR FURRED DOWN TO 8′2″

8.166667 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: THIS CORRIDOR FURRED DOWN TO 8′2″

Applies to the subsidiary U.S. Attorney corridor only, not the Main public corridor or all rooms.

f5-room-525verified · printed

printed_plan_horizontal_span

10′6″

10.5 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 10′6″

Printed wall-face/witness span at Main-side office; depth and other boundaries are traced separately.

f5-room-524verified · printed

printed_plan_horizontal_span

11′0″

11 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 11′0″

Printed wall-face/witness span at Main-side office; depth and other boundaries are traced separately.

f5-room-523verified · printed

printed_plan_horizontal_span

11′8″

11.666667 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 11′8″

Printed wall-face/witness span at Main-side office; depth and other boundaries are traced separately.

f5-corridor-mainverified · printed

printed_plan_clear_width

8′2″

8.166667 ft

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 8′2″

Plan width, distinct from the same numerical ceiling-height notation in the subsidiary corridor.

f5-attorney-partition-typeverified · printed

printed_partition_thickness

4″

4 in

IMG_1214 · sheet-W7 · Locate on drawing ↗

Drawing notation: 4″

Local partition note between printed office-width spans; not generalized to every wall.

f5-w7-room522-521-partition-witnessverified · printed

page_left_local_offset

6"

6 in

Small dimension immediately page-left of partition axis beside Room 522. This is a local offset witness, not the full wall thickness or room width; exact endpoint face class pending.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 6"

Small dimension immediately page-left of partition axis beside Room 522. This is a local offset witness, not the full wall thickness or room width; exact endpoint face class pending.

f5-w7-room522-521-partition-witnessverified · printed

page_right_local_offset

4"

4 in

Separate page-right offset witness at same partition. Not summed into accepted wall thickness; face and axis equivalence require independent tracing.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 4"

Separate page-right offset witness at same partition. Not summed into accepted wall thickness; face and axis equivalence require independent tracing.

f5-room-525verified · printed

printed_room_number

525 [circled]

525 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 525 [circled]

Source-local property only; no accepted transform or solid.

f5-room-524verified · printed

printed_room_number

524 [circled]

524 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 524 [circled]

Source-local property only; no accepted transform or solid.

f5-room-523verified · printed

printed_room_number

523 [circled]

523 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 523 [circled]

Source-local property only; no accepted transform or solid.

f5-room-522verified · printed

printed_room_number

522 [circled]

522 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 522 [circled]

Source-local property only; no accepted transform or solid.

f5-room-521verified · printed

printed_room_number

521 [circled]

521 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 521 [circled]

Source-local property only; no accepted transform or solid.

f5-room-520verified · printed

printed_room_number

520 [circled]

520 identifier

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 520 [circled]

Source-local property only; no accepted transform or solid.

f5-room-525verified · printed

printed_partition_face_span

10′-6″

10.5 ft

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 10′-6″

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

f5-room-524verified · printed

printed_partition_face_span

11′-0″

11 ft

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 11′-0″

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

f5-room-523verified · printed

printed_partition_face_span

11′-8″

11.666667 ft

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: 11′-8″

Dimension chain spans drawn partition faces; finish versus rough face not established. Adjacent 4-inch partition dimension separate, not added to room width.

f5-main-attorney-corridorverified · printed

furred_ceiling_height

THIS CORRIDOR FURRED DOWN TO 8′-2″

8.166667 ft

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: THIS CORRIDOR FURRED DOWN TO 8′-2″

Source-local property only; no accepted transform or solid.

f5-room-525-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

f5-room-524-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

f5-room-523-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

f5-room-522-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

f5-room-521-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

f5-room-520-corridor-openingverified · printed

printed_type_mark

A

Source-local property only; no accepted transform or solid.

IMG_1214 · W7 · Locate on drawing ↗

Drawing notation: A

Source-local property only; no accepted transform or solid.

View all source photographs →