Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
w242-room605-chamber-section-trimillegible · printed
chamber-inset-panel-vertical-witness
6′-6[fraction unresolved]Numeric value unresolved
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed inset panel vertical witness fraction not securely established; value withheld. Distinct from complete section 10′-7½″.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 6′-6[fraction unresolved]
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Printed inset panel vertical witness fraction not securely established; value withheld. Distinct from complete section 10′-7½″.
w242-room605-chamber-section-trimillegible · printed
chamber-lower-panel-vertical-witness
1′-5[fraction unresolved]Numeric value unresolved
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Lower chamber panel vertical interval fraction not securely established; value withheld. Frame/wall applicability remains local.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 1′-5[fraction unresolved]
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry. Lower chamber panel vertical interval fraction not securely established; value withheld. Frame/wall applicability remains local.
w242-room605-chamber-section-trimverified · printed
chamber-bottom-base-height
6″6 in
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 6″
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
w242-room605-chamber-section-trimverified · printed
chamber-floor-datum-label
FIN. 6TH FLOORPrinted source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: FIN. 6TH FLOOR
Printed source-local detail control. Exact historical revision and physical installation unresolved; does not accept whole-room geometry.
w242-room605-chamber-section-trimverified · printed
chamber_printed_room_number
JUDGES CHAMBER (ROOM 605)605 room
Printed chamber elevation assignment; no dimension transferred into floor geometry.
w242-room605-chamber-section-trimverified · printed
similar_room_reference
ROOM 609 SIMILAR609 room
Similarity reference only; does not prove identical coordinates, dimensions or installation.
w242-room605-chamber-section-trimverified · printed
cornice_carving
CARVED WOODSection top leader; species not established from this crop.
w242-room605-chamber-section-trimverified · printed
curtain_pocket
CURTAIN POCKETUpper section pocket leader; depth and mechanism unresolved.
w242-room605-chamber-section-trimverified · printed
section_vertical_dimension
10'-7 1/2"127.5 in
Outer section vertical dimension adjacent chamber detail; breaks and datum ownership require review before interpreting as room ceiling height.
IMG_1177 · W-242 · Locate on drawing ↗Drawing notation: 10'-7 1/2"
Outer section vertical dimension adjacent chamber detail; breaks and datum ownership require review before interpreting as room ceiling height.
w242-room605-chamber-section-trimverified · printed
chamber_section_column_pocket
COLUMN POCKETCaption beside chamber section pocket, distinct from existing curtain-pocket caption. Pocket extent/profile and installed location need section/plan reconciliation.
IMG_1177 · Locate on drawing ↗Drawing notation: COLUMN POCKET
Caption beside chamber section pocket, distinct from existing curtain-pocket caption. Pocket extent/profile and installed location need section/plan reconciliation.