Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
w240-balustrade-newel-fixing-assemblyverified · printed
newel_plate_bolt_count
EACH NEWELL TO BE SECURED WITH 4 — 1/2" BOLTS TO CAST IRON PLATE4 bolts
Count per depicted newel, not installed newel total. Resolves size/count uncertainty in detail-courts-20261010-img1173-m003; original null retained in prior package.
IMG_1173 · W-240 · Locate on drawing ↗Drawing notation: EACH NEWELL TO BE SECURED WITH 4 — 1/2" BOLTS TO CAST IRON PLATE
Count per depicted newel, not installed newel total. Resolves size/count uncertainty in detail-courts-20261010-img1173-m003; original null retained in prior package.
w240-balustrade-newel-fixing-assemblyverified · printed
newel_plate_bolt_diameter
4 — 1/2" BOLTS0.5 in
Diameter in bolt specification; no length given.
w240-balustrade-newel-fixing-assemblyverified · printed
floor_expansion_anchor_count
ANCHORED BY 2 — 4" x 1/2" EXPANSION BOLTS2 bolts
Expansion anchor count for plate-to-floor fixing, distinct from four newel bolts.
w240-balustrade-newel-fixing-assemblyverified · printed
floor_expansion_anchor_length
2 — 4" x 1/2" EXPANSION BOLTS4 in
First dimension interpreted as anchor length, conventional length x diameter notation; thread/embedment unresolved.
IMG_1173 · W-240 · Locate on drawing ↗Drawing notation: 2 — 4" x 1/2" EXPANSION BOLTS
First dimension interpreted as anchor length, conventional length x diameter notation; thread/embedment unresolved.
w240-balustrade-newel-fixing-assemblyverified · printed
floor_expansion_anchor_diameter
2 — 4" x 1/2" EXPANSION BOLTS0.5 in
Second dimension in printed expansion bolt notation; not plate thickness.