Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
structsched1013g-img1329-beam-schedule-b10verified · printed
scheduled_width_notation
12Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header.
IMG_1329 · W-415 · Locate on drawing ↗Drawing notation: 12
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header.
structsched1013g-img1329-beam-schedule-b10verified · printed
scheduled_depth_notation
36Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header.
IMG_1329 · W-415 · Locate on drawing ↗Drawing notation: 36
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header.
structsched1013g-img1329-beam-schedule-b10unreviewed · printed
scheduled_width_numeric
12Numeric value unresolved
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header. Unit must be verified before a numeric length is normalized.
IMG_1329 · W-415 · Locate on drawing ↗Drawing notation: 12
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header. Unit must be verified before a numeric length is normalized.
structsched1013g-img1329-beam-schedule-b10unreviewed · printed
scheduled_depth_numeric
36Numeric value unresolved
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header. Unit must be verified before a numeric length is normalized.
IMG_1329 · W-415 · Locate on drawing ↗Drawing notation: 36
Front entrance-step concrete beam schedule row B10; no installed beam inventory or world geometry. WIDTH/DEPTH cells have no unit printed in inspected header. Unit must be verified before a numeric length is normalized.
structsched1013g-img1329-beam-schedule-b10verified · printed
straight_rod_quantity
3 - [rod fraction unresolved] φ3 count
Type-component quantity in B10 STR.RODS cell only; nominal rod fraction, physical size and installed count remain separate.
IMG_1329 · W-415 · Locate on drawing ↗Drawing notation: 3 - [rod fraction unresolved] φ
Type-component quantity in B10 STR.RODS cell only; nominal rod fraction, physical size and installed count remain separate.
structsched1013g-img1329-beam-schedule-b10verified · printed
stirrup_omission
NONEB10 STIRRUPS spacing cell prints NONE; no universal omission.
structsched1013g-img1329-beam-schedule-b10verified · printed
top_rods_notation
[blank]B10 TOP RODS cell visibly blank in inspected crop; not evidence of a general no-top-rods construction rule.