Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
structsched1013g-img1327-beam-fireproofingverified · printed
mesh_specification
6 × 6 #10 WIRE MESHLiteral mesh annotation beside typical beam fireproofing. #10 is a gauge/designation token, not thickness; mesh pitch units await governing convention.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: 6 × 6 #10 WIRE MESH
Literal mesh annotation beside typical beam fireproofing. #10 is a gauge/designation token, not thickness; mesh pitch units await governing convention.
structsched1013g-img1327-beam-fireproofingverified · printed
mesh_anchoring_method
BEND MESH AROUND TOP FLANGE. CLIPS SIMILAR TO THOSE USED FOR COLS.Beam enclosure anchoring rule; column clips require separate dimensions/applicability.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: BEND MESH AROUND TOP FLANGE. CLIPS SIMILAR TO THOSE USED FOR COLS.
Beam enclosure anchoring rule; column clips require separate dimensions/applicability.
structsched1013g-img1327-beam-fireproofingverified · printed
other_shape_application
NOTE: USE SIMILAR METHOD OF SECURING WIRE MESH FOR ALL STRUCTURAL SHAPESPrinted instruction to use similar securing method, not one uniform enclosure geometry.
IMG_1327 · W-413 · Locate on drawing ↗Drawing notation: NOTE: USE SIMILAR METHOD OF SECURING WIRE MESH FOR ALL STRUCTURAL SHAPES
Printed instruction to use similar securing method, not one uniform enclosure geometry.
structsched1013g-img1327-beam-fireproofingverified · printed
bottom_enclosure_witness
2″2 in
Vertical bottom cover witness at typical beam enclosure, distinct from earlier roof-slab candidate.
structsched1013g-img1327-beam-fireproofingverified · printed
side_enclosure_witness
2″2 in
Horizontal side cover witness at typical beam enclosure, distinct from earlier roof-slab candidate.