Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stairs1014y-1133-sixthverified · printed
sixth_floor_clear_hatch_vertical_witness
8′-1″ CLEAR HATCH97 in
Vertical clear-hatch dimension, distinct from adjacent 8ft2in witness; does not close aggregate other-hatch-dimensions question. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 8′-1″ CLEAR HATCH
Vertical clear-hatch dimension, distinct from adjacent 8ft2in witness; does not close aggregate other-hatch-dimensions question. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_inner_vertical_witness
8′-2″98 in
Adjacent left vertical interior witness; exact finish/car/structure endpoints remain unclassified. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 8′-2″
Adjacent left vertical interior witness; exact finish/car/structure endpoints remain unclassified. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_lower_internal_horizontal_witness
7′-4¾″88.75 in
Lower internal width witness, distinct from verified 7ft0in clear hatch. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 7′-4¾″
Lower internal width witness, distinct from verified 7ft0in clear hatch. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_left_lateral_witness
5′-2″62 in
Left lateral line to hatch enclosure; source-local endpoints only. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 5′-2″
Left lateral line to hatch enclosure; source-local endpoints only. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_upper_right_horizontal_witness
3′-1″37 in
Upper right witness from enclosure/door-side line toward external reference. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 3′-1″
Upper right witness from enclosure/door-side line toward external reference. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_lower_right_horizontal_witness
2′-2¼″26.25 in
Lower right horizontal witness; not interchangeable with upper 3ft1in station. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 2′-2¼″
Lower right horizontal witness; not interchangeable with upper 3ft1in station. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_right_external_vertical_witness
4′-11″59 in
Right external vertical chain between two visible horizontal witness lines. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 4′-11″
Right external vertical chain between two visible horizontal witness lines. Source-local only; no installed geometry or historical issue selected.
stairs1014y-1133-sixthverified · printed
sixth_floor_upper_strip_vertical_witness
1′-10″22 in
Vertical witness across strip above shaft plan; wall thickness and structural purpose unaccepted. Source-local only; no installed geometry or historical issue selected.
IMG_1133 · W-230 · Locate on drawing ↗Drawing notation: 1′-10″
Vertical witness across strip above shaft plan; wall thickness and structural purpose unaccepted. Source-local only; no installed geometry or historical issue selected.