Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-e-w225-section-bbverified · printed
First-to-second finished-floor interval
21'-0"21 ft
Printed vertical chain in Section B-B; agrees with the accepted local floor datums.
IMG_1262 · sheet-W225 · Locate on drawing ↗Drawing notation: DETAILS OF STAIR E / LOWER STORIES / W225
One complete source and sequential crops from the same photograph were inspected. Pixel distances were not used as architectural dimensions.
stair-e-w225-section-bbverified · printed
Basement-to-first finished-floor interval
15'-0"15 ft
Printed vertical chain in Section B-B. It conflicts with the generic -13 ft basement reference and is therefore not applied to current geometry.
IMG_1262 · sheet-W225 · Locate on drawing ↗Drawing notation: DETAILS OF STAIR E / LOWER STORIES / W225
One complete source and sequential crops from the same photograph were inspected. Pixel distances were not used as architectural dimensions.
stair-e-w225-section-bbverified · printed
regional_basement_interval_conflict_disposition
15′0″ between FINISH BASEMENT FLOOR and EL93.25 FINISH1ST FLOORAlternate Section A-A visibly corroborates retained W22515ft interval;13ft generic/C region cannot replace it. No independent E basement absolute datum is read. Conflict remains unresolved; prior exact15ft property reused.
IMG_1116 · W-225 · Locate on drawing ↗Drawing notation: 15′0″ between FINISH BASEMENT FLOOR and EL93.25 FINISH1ST FLOOR
Alternate Section A-A visibly corroborates retained W22515ft interval;13ft generic/C region cannot replace it. No independent E basement absolute datum is read. Conflict remains unresolved; prior exact15ft property reused.
Calculated from: w225-basement-f1-vertical-interval, w225-first-floor-finish-elevation
stair-e-w225-section-bbunreviewed · printed
regional_basement_absolute_finish_elevation_unresolved
[E basement absolute elevation absent from reviewed finished-floor label]Numeric value unresolved
This crop does not establish an independently printed absolute basement datum. A93.25−15 calculation would remain calculated and would not resolve cross-source regional authority.
IMG_1116 · W-225 · Locate on drawing ↗Drawing notation: [E basement absolute elevation absent from reviewed finished-floor label]
This crop does not establish an independently printed absolute basement datum. A93.25−15 calculation would remain calculated and would not resolve cross-source regional authority.
stair-e-w225-section-bbverified · printed
middle_intermediate_landing_vertical_interval
5′10″70 in
Section B-B vertical witness from lower landing walking-surface line to upper landing walking-surface line. Distinct from top interval with same printed value.
IMG_1262 · W-225 · Locate on drawing ↗Drawing notation: 5′10″
Section B-B vertical witness from lower landing walking-surface line to upper landing walking-surface line. Distinct from top interval with same printed value.
stair-e-w225-section-bbverified · printed
upper_landing_to_second_floor_vertical_interval
5′10″70 in
Section B-B witness from upper intermediate landing to second-floor finished walking-surface line.
stair-e-w225-section-bbverified · printed
plan_section_landing_elevation_correspondence
9′4″ + 5′10″ + 5′10″ between1ST FLOOR and2ND FLOORB-B lower interval independently reads9′4″, matching plan left elevation; middle interval leads to plan15′2″. Existing21ft overall reused. Relationship only; no riser recipe or building transform.
IMG_1262 · W-225 · Locate on drawing ↗Drawing notation: 9′4″ + 5′10″ + 5′10″ between1ST FLOOR and2ND FLOOR
B-B lower interval independently reads9′4″, matching plan left elevation; middle interval leads to plan15′2″. Existing21ft overall reused. Relationship only; no riser recipe or building transform.
Calculated from: stair-fine1013e-img_1262-m005, stair-fine1013e-img_1262-m006, w225-f1-f2-vertical-interval