Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-e-w225-folding-gateverified · printed
lock_side_relationship
ON OUTER SIDE OF GATEPrinted leader in AT A/AT B details identifies outer-side placement of depicted lock fitting.
stair-e-w225-folding-gateverified · printed
gate_lock_presence
LOCKPrinted plan lock leader; lock type, size, handedness and attachment not established.
stair-e-w225-folding-gateneeds-review · printed
gate_section_bar_fraction_unresolved
[fraction] x 1 1/2" BARNumeric value unresolved
Second gate detail exposure contains fractional bar callout; numerator withheld instead of transferring Stair A dimensions.
IMG_1117 · W-225 · Locate on drawing ↗Drawing notation: [fraction] x 1 1/2" BAR
Second gate detail exposure contains fractional bar callout; numerator withheld instead of transferring Stair A dimensions.
stair-e-w225-folding-gateverified · printed
gate_section_bar_thickness
¼″ × 1½″ BAR0.25 in
Original white printed drawing layer. Same gate-plan bar leader as prior fraction-null question. Source-local bar section, not Stair A transfer or installed quantity.
IMG_1117 · W-225 · Locate on drawing ↗Drawing notation: ¼″ × 1½″ BAR
Original white printed drawing layer. Same gate-plan bar leader as prior fraction-null question. Source-local bar section, not Stair A transfer or installed quantity.
stair-e-w225-folding-gateverified · printed
gate_section_bar_width
¼″ × 1½″ BAR1.5 in
Original white printed drawing layer. Second dimension of same gate-plan bar section; actual fabricated length and profile stations unknown.
IMG_1117 · W-225 · Locate on drawing ↗Drawing notation: ¼″ × 1½″ BAR
Original white printed drawing layer. Second dimension of same gate-plan bar section; actual fabricated length and profile stations unknown.
stair-e-w225-folding-gateverified · printed
gate_plan_channel_nominal_designation
1¼″ CHANNEL1.25 in
Original white printed drawing layer. Leader to gate-plan frame section at lock-side fitting; nominal designation only, not outside dimensions/steel weight.
IMG_1117 · W-225 · Locate on drawing ↗Drawing notation: 1¼″ CHANNEL
Original white printed drawing layer. Leader to gate-plan frame section at lock-side fitting; nominal designation only, not outside dimensions/steel weight.