Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-c-w223-first-second-flight-registerverified · printed
lower_flight_tread_count
10 TREADS @ 10½" = 8'-9"10 count
First-floor bottom horizontal up-flight only; 36 total risers from existing directional record retained separately.
IMG_1113 · W-223 · Locate on drawing ↗Drawing notation: 10 TREADS @ 10½" = 8'-9"
First-floor bottom horizontal up-flight only; 36 total risers from existing directional record retained separately.
stair-c-w223-first-second-flight-registerverified · printed
lower_flight_tread_going
10 TREADS @ 10½" = 8'-9"10.5 in
Scope is first-floor lower flight; full adjoining vertical chain and second-floor return flight still need targeted certification.
IMG_1113 · W-223 · Locate on drawing ↗Drawing notation: 10 TREADS @ 10½" = 8'-9"
Scope is first-floor lower flight; full adjoining vertical chain and second-floor return flight still need targeted certification.
stair-c-w223-first-second-flight-registerverified · printed
middle_flight_tread_count
12 TREADS @ 10½" = 10'-6"12 count
Vertical chain in first-floor plan, confirmed with master crop. Lower 10-tread chain retained from IMG_1113.
stair-c-w223-first-second-flight-registerverified · printed
middle_flight_tread_going
12 TREADS @ 10½" = 10'-6"10.5 in
Middle-flight printed going only.
stair-c-w223-first-second-flight-registerverified · printed
middle_flight_run
12 TREADS @ 10½" = 10'-6"126 in
Printed middle-flight run; break/gate arrangement and actual physical endpoint classes still require review.
stair-c-w223-first-second-flight-registerunreviewed · derived
middle_flight_riser_count_candidate
12 printed treads + 1 terminal rise13 count
Candidate allocation, not a printed per-flight riser total.
Calculated from: stair-companion1013b-img_1260-m005
stair-c-w223-first-second-flight-registerverified · printed
upper_flight_tread_count
11 TREADS @ 10½" = 9'-7½"11 count
Upper horizontal return flight in second-floor plan; printed chain legible.
stair-c-w223-first-second-flight-registerverified · printed
upper_flight_tread_going
11 TREADS @ 10½" = 9'-7½"10.5 in
Upper-flight printed going only.
stair-c-w223-first-second-flight-registerverified · printed
upper_flight_run
11 TREADS @ 10½" = 9'-7½"115.5 in
Upper-flight printed product/run, separate from previously verified basement lower-flight identical notation.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: 11 TREADS @ 10½" = 9'-7½"
Upper-flight printed product/run, separate from previously verified basement lower-flight identical notation.
stair-c-w223-first-second-flight-registerunreviewed · derived
upper_flight_riser_count_candidate
11 printed treads + 1 terminal rise12 count
Candidate tread-plus-one allocation; actual nosing and landing conventions still unresolved.
Calculated from: stair-companion1013b-img_1260-m009
stair-c-w223-first-second-flight-registerunreviewed · derived
three_flight_riser_sum_candidate
(10 + 1) + (12 + 1) + (11 + 1) = 3636 count
Candidate 11+13+12 allocation agrees with existing UP36/DOWN36, which does not certify the per-flight allocation. Parent lower tread reading reused, not duplicated.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: (10 + 1) + (12 + 1) + (11 + 1) = 36
Candidate 11+13+12 allocation agrees with existing UP36/DOWN36, which does not certify the per-flight allocation. Parent lower tread reading reused, not duplicated.
Calculated from: stair-closeout1013a-img_1113-m008, stair-companion1013b-img_1260-m008, stair-companion1013b-img_1260-m012
stair-c-w223-first-second-flight-registerverified · printed
lower_flight_transverse_source_witness
3′10½″46.5 in
First-floor lower up-flight strip width, witnessed through drawn boundary/rail region; no rail-face clearance certified.
stair-c-w223-first-second-flight-registerverified · printed
middle_flight_transverse_source_witness
3′10½″46.5 in
First-floor vertical middle-flight strip witness; multiple shaft/string/rail lines prevent a finish-face equivalence claim.
stair-c-w223-first-second-flight-registerverified · printed
first_turn_landing_longitudinal_source_witness
5′0″60 in
First-floor bottom-right landing horizontal span from lower/middle flight junction to inner drawn wall line. No accepted closed landing polygon.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: 5′0″
First-floor bottom-right landing horizontal span from lower/middle flight junction to inner drawn wall line. No accepted closed landing polygon.
stair-c-w223-first-second-flight-registerverified · printed
upper_flight_transverse_source_witness
3′10½″46.5 in
Second-floor upper horizontal return flight transverse witness. Bronze handrail overlaps source edge region; physical clearance remains unresolved.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: 3′10½″
Second-floor upper horizontal return flight transverse witness. Bronze handrail overlaps source edge region; physical clearance remains unresolved.
stair-c-w223-first-second-flight-registerunreviewed · printed
second_turn_landing_longitudinal_source_witness_unresolved
4′[fractional inches not certified]Numeric value unresolved
Fine upper right landing fraction not certified from this crop; no subtraction from overall chain.
stair-c-w223-first-second-flight-registerverified · observed
signed_ascent_source_page
[first-floor lower numbered strip proceeds right; middle strip proceeds up; second-floor upper strip proceeds left through25…36]Links the reviewed C plan strips by source numbering and the existing upper-chain scope. No duplicate tread/riser counts; no accepted cross-floor transform.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: [first-floor lower numbered strip proceeds right; middle strip proceeds up; second-floor upper strip proceeds left through25…36]
Links the reviewed C plan strips by source numbering and the existing upper-chain scope. No duplicate tread/riser counts; no accepted cross-floor transform.
Calculated from: stair-companion1013b-img_1260-m005, stair-companion1013b-img_1260-m009
stair-c-w223-first-second-flight-registerverified · observed
ascent_turn_handedness_source_page
[two left turns: right→up→left; counterclockwise around Elevator No.2 in the paper x-right/y-up frame]Source-local turn handedness; both intermediate landing polygon limits and their elevations remain open.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: [two left turns: right→up→left; counterclockwise around Elevator No.2 in the paper x-right/y-up frame]
Source-local turn handedness; both intermediate landing polygon limits and their elevations remain open.
stair-c-w223-first-second-flight-registerverified · observed
bronze_rail_boundary_relationship
[BRONZE HANDRAIL leader and rail line occupy shaft-side lower/upper flight boundary regions]New boundary relationship, using existing material rule rather than repeating bronze as a new universal stair material assignment.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: [BRONZE HANDRAIL leader and rail line occupy shaft-side lower/upper flight boundary regions]
New boundary relationship, using existing material rule rather than repeating bronze as a new universal stair material assignment.
Calculated from: door-20261012a-1122-m005
stair-c-w223-first-second-flight-registerverified · observed
section_finished_floor_witness_endpoint_class
FIN. 1ST FLOOR / FIN. 2ND FLOOR [vertical witness terminates at finished walking surface/slab-top reference]Section B-B21ft chain is between finish-floor surface references, not soffit/rough-slab-bottom or rail-top planes. Prior exact floor interval reused; no new building coordinate.
IMG_1113 · W-223 · Locate on drawing ↗Drawing notation: FIN. 1ST FLOOR / FIN. 2ND FLOOR [vertical witness terminates at finished walking surface/slab-top reference]
Section B-B21ft chain is between finish-floor surface references, not soffit/rough-slab-bottom or rail-top planes. Prior exact floor interval reused; no new building coordinate.
stair-c-w223-first-second-flight-registerunreviewed · observed
section_finish_rough_rail_plane_equivalence_unresolved
[finished floor lines, hatched structural support and rail lines shown separately]Numeric value unresolved
Wall finish build-up, rough structural reference and rail intrusion offsets remain unmeasured; section appearance cannot supply physical clear width.
IMG_1113 · W-223 · Locate on drawing ↗Drawing notation: [finished floor lines, hatched structural support and rail lines shown separately]
Wall finish build-up, rough structural reference and rail intrusion offsets remain unmeasured; section appearance cannot supply physical clear width.
stair-c-w223-first-second-flight-registerverified · printed
second_turn_landing_fractional_source_witness_resolution
4′1½″49.5 in
Upper right second-floor return landing projection from station25-side flight endpoint to inner drawn wall reference. Resolves prior fractional null, not clear width or a closed landing polygon.
IMG_1260 · W-223 · Locate on drawing ↗Drawing notation: 4′1½″
Upper right second-floor return landing projection from station25-side flight endpoint to inner drawn wall reference. Resolves prior fractional null, not clear width or a closed landing polygon.