Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
stair-b-w222-seventh-approachverified · printed
upper-story-rise
11'-6"138 in
Upper B-B dimension between FIN. 6TH FLOOR and FIN. 7TH FLOOR; floor datum mapping and headroom unresolved.
stair-b-w222-seventh-approachverified · printed
flight-horizontal-witness
7'-0"84 in
Upper A-A horizontal witness over flight; tread/nosing endpoints not classified. Do not equate this to net physical run.
stair-b-w222-seventh-approachverified · printed
wall-finish
TILEPrinted TILE leader at left upper A-A wall; thickness and extent unresolved.
stair-b-w222-seventh-approachverified · printed
upper_section_left_horizontal_witness
4'-9"57 in
Upper A-A left chain segment; surrounding fractions and witness face classification remain unresolved.
stair-b-w222-seventh-approachneeds-review · printed
upper_section_adjacent_fractional_witness_unresolved
3'-11 [fraction]"Numeric value unresolved
Adjacent fractional chain glyph cannot be verified in access crop. Null preserved; no chain closure calculation.
stair-b-w222-seventh-approachverified · observed
upper_section_horizontal_chain_reference_classes
[seventh-floor chain passes wall/tile reference, beam station, newel side and return wall reference]Master crop distinguishes newel-side and wall/tile-reference stations; existing 57in and84in spans retained. Beam-centre and finish-face exact equivalence not accepted; this is an observed dimension-chain inventory.
IMG_1112 · W-222 · Locate on drawing ↗Drawing notation: [seventh-floor chain passes wall/tile reference, beam station, newel side and return wall reference]
Master crop distinguishes newel-side and wall/tile-reference stations; existing 57in and84in spans retained. Beam-centre and finish-face exact equivalence not accepted; this is an observed dimension-chain inventory.
Calculated from: stairs1012a-1112-m001, detail-20261011j-1112-m003
stair-b-w222-seventh-approachillegible · printed
upper_section_fractional_witness_followup_unresolved
3′11 [fraction]″Numeric value unresolved
Native crop still does not securely distinguish the fine fractional suffix. Existing null retained; no difference or chain closure used.
IMG_1112 · W-222 · Locate on drawing ↗Drawing notation: 3′11 [fraction]″
Native crop still does not securely distinguish the fine fractional suffix. Existing null retained; no difference or chain closure used.
Calculated from: stairs1012a-1112-m002
stair-b-w222-seventh-approachverified · observed
upper_section_sloped_guard_newel_relationship
[sloped rail with vertical infill connects elevated end newels above stair flight]Original white printed drawing layer. Observed A-A upper-flight guard arrangement only; rail section, newel dimensions, installation and precise terminal-floor relation remain unresolved.
IMG_1112 · W-222 · Locate on drawing ↗Drawing notation: [sloped rail with vertical infill connects elevated end newels above stair flight]
Original white printed drawing layer. Observed A-A upper-flight guard arrangement only; rail section, newel dimensions, installation and precise terminal-floor relation remain unresolved.