Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
seventh-floor-w235-to-plan-registration-gateverified · observed
W-235 analytical component placement gate
FAIL — diagnostic registration exceeds toleranceThe candidate fit has 4.297 feet held-out RMS and 7.456 feet maximum residual, exceeds the 1.75-foot diagnostic tolerance, and depends on unclassified wall-line endpoints plus a provisional target registration. Therefore no W-235 fixture or compartment-partition coordinate may be inserted into the building model.
seventh-floor-w235-to-plan-registration-gateverified · observed
Verified topological identity correspondences
44 count
Room, janitor-closet and elevator identities/adjoining relationships only; no metric control is accepted.
seventh-floor-w235-to-plan-registration-gateunreviewed · derived
Rejected diagnostic held-out RMS
4.297 ft diagnostic4.297413 ft
Four-point projective fit from normalized IMG_1272 coordinates to canonical plan feet. Target feet are inherited from the provisional IMG_1221 homography. The four fitted points have zero algebraic residual by construction and are not accuracy evidence.
seventh-floor-w235-to-plan-registration-gateunreviewed · derived
Rejected diagnostic maximum residual
7.456 ft diagnostic7.455803 ft
Candidate point locations are manual diagnostic picks, not accepted dimension endpoints. W-235 is a photographed detail sheet with visible perspective and paper distortion; one projective transform cannot correct local deformation. The target IMG_1221 plan registration and room polygons are already provisional. Several candidate walls are heavy bands whose finish face, structural face and centerline are not classified consistently across the two drawings. The west Elevator No.1 checks miss by more than six feet while the east checks are much smaller, indicating that the candidate mapping is not stable across the block.
seventh-floor-w235-to-plan-registration-gateunreviewed · derived
Diagnostic residual tolerance
1.75 ft1.75 ft
The upstream IMG_1221 registration declares a 1.75-foot control-picking uncertainty. A second registration must not add multi-foot independent residuals before fixture placement.
seventh-floor-w235-to-plan-registration-gateverified · observed
Accepted W-235 to building transform
UnresolvedThe candidate fit has 4.297 feet held-out RMS and 7.456 feet maximum residual, exceeds the 1.75-foot diagnostic tolerance, and depends on unclassified wall-line endpoints plus a provisional target registration. Therefore no W-235 fixture or compartment-partition coordinate may be inserted into the building model.
seventh-floor-w235-to-plan-registration-gateverified · observed
Accepted bathroom fixture placement
NoneAll nine saved fixture identities remain unplaced.
seventh-floor-w235-to-plan-registration-gateverified · observed
Accepted compartment-partition placement
NoneAll three saved partition identities remain unplaced.