Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
servicesched1013f-house-tank-section-aaillegible · printed
shell_fraction_still_illegible
[fraction unreadable] SHELLNumeric value unresolved
Native same original house-tank shell witness still illegible; no3/8 substitution.
IMG_1340 · Locate on drawing ↗Drawing notation: [fraction unreadable] SHELL
Native same original house-tank shell witness still illegible; no3/8 substitution.
servicesched1013f-house-tank-section-aaillegible · printed
head_fraction_still_illegible
[fraction unreadable] HEADSNumeric value unresolved
Native same original house-tank head witness still illegible; no1/2 substitution.
IMG_1340 · Locate on drawing ↗Drawing notation: [fraction unreadable] HEADS
Native same original house-tank head witness still illegible; no1/2 substitution.
servicesched1013f-house-tank-section-aaverified · printed
tank_designation
HOUSE TANKSource-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaverified · printed
diameter
64″ DIA.64 in
Source-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaverified · printed
length
16′-0″ LONG16 ft
Source-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaunreviewed · printed
shell_thickness_unreviewed
[3/8″?] SHELLNumeric value unresolved
Small fraction insufficiently certain for verified gauge; candidate retained without numeric substitution.
servicesched1013f-house-tank-section-aaunreviewed · printed
head_thickness_unreviewed
[1/2″?] HEADSNumeric value unresolved
Small fraction insufficiently certain for verified gauge; candidate retained without numeric substitution.
servicesched1013f-house-tank-section-aaverified · printed
original_saddle_material
CAST IRON SADDLESSource-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaverified · printed
original_support_relation
CAST IRON SADDLES ON CONCRETE PIERSSource-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
IMG_1340 · W-PH460 · Locate on drawing ↗Drawing notation: CAST IRON SADDLES ON CONCRETE PIERS
Source-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaverified · printed
pier_material
CONCRETE PIERSSource-local printed schedule/detail property only; no installed quantity, physical coordinates or architectural approval.
servicesched1013f-house-tank-section-aaverified · observed
support_annotation
STRUCTURAL STEELYellow annotation crosses original saddle/support note; authority and support revision unresolved. Not substituted for original CAST IRON SADDLES.
IMG_1340 · W-PH460 · Locate on drawing ↗Drawing notation: STRUCTURAL STEEL
Yellow annotation crosses original saddle/support note; authority and support revision unresolved. Not substituted for original CAST IRON SADDLES.