Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
servicenotes-img1330-basement-return-notesverified · printed
return_runout_default_size
ALL RETURN RUNOUTS TO BE 1″1 in
Printed separate return-runout clause only, qualified UNLESS OTHERWISE NOTED. The adjacent fractional drip-runout size remains unreadable, so the earlier compound question is not closed.
IMG_1330 · Locate on drawing ↗Drawing notation: ALL RETURN RUNOUTS TO BE 1″
Printed separate return-runout clause only, qualified UNLESS OTHERWISE NOTED. The adjacent fractional drip-runout size remains unreadable, so the earlier compound question is not closed.
servicenotes-img1330-basement-return-notesverified · printed
riser_drip_term
ALL RETURN RISERS AND RISER DRIPSExact named components in first return-note line. Verifies RISER DRIPS wording only; does not establish the blurred fraction or close the prior compound size question.
IMG_1330 · Locate on drawing ↗Drawing notation: ALL RETURN RISERS AND RISER DRIPS
Exact named components in first return-note line. Verifies RISER DRIPS wording only; does not establish the blurred fraction or close the prior compound size question.
servicenotes-img1330-basement-return-notesverified · printed
trench_return_pipe_material
RETURN PIPING IN TRENCHES TO BE BRASS WITH BRASS FITTINGSMaterial note specifically applies to return piping in trenches; does not assign material to other piping.
IMG_1330 · W-450 · Locate on drawing ↗Drawing notation: RETURN PIPING IN TRENCHES TO BE BRASS WITH BRASS FITTINGS
Material note specifically applies to return piping in trenches; does not assign material to other piping.
servicenotes-img1330-basement-return-notesverified · printed
condensation_trap_valve_relationship
CONDENSATION FLOAT AND THERMOSTATIC TRAPS WITH VALVES SHOWN INDICATED THUS [symbol]Legend states association between depicted trap symbols and valves; no installed trap quantity established.
IMG_1330 · W-450 · Locate on drawing ↗Drawing notation: CONDENSATION FLOAT AND THERMOSTATIC TRAPS WITH VALVES SHOWN INDICATED THUS [symbol]
Legend states association between depicted trap symbols and valves; no installed trap quantity established.
servicenotes-img1330-basement-return-notesverified · printed
thermostatic_trap_symbol_relationship
THERMOSTATIC TRAPS INDICATED THUS [symbol]Separate thermostatic-trap legend preserved; individual plan symbols not enumerated.
servicenotes-img1330-basement-return-notesunreviewed · printed
return_riser_and_drop_default_size
ALL RETURN RISERS AND [word unclear] DRIPS TO BE [fraction unclear] UNLESS OTHERWISE NOTEDNumeric value unresolved
Numeral is too blurred to normalize; retained separately from return runout note.
IMG_1330 · W-450 · Locate on drawing ↗Drawing notation: ALL RETURN RISERS AND [word unclear] DRIPS TO BE [fraction unclear] UNLESS OTHERWISE NOTED
Numeral is too blurred to normalize; retained separately from return runout note.
servicenotes-img1330-basement-return-notesunreviewed · printed
return_runout_default_size
ALL RETURN RUNOUTS TO BE [size unclear] AND DRIP RUNOUTS TO BE [fraction unclear] UNLESS OTHERWISE NOTEDNumeric value unresolved
Runout and drip runout values require better source resolution; no numerical guesses normalized.
IMG_1330 · W-450 · Locate on drawing ↗Drawing notation: ALL RETURN RUNOUTS TO BE [size unclear] AND DRIP RUNOUTS TO BE [fraction unclear] UNLESS OTHERWISE NOTED
Runout and drip runout values require better source resolution; no numerical guesses normalized.