Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
plangap1012k-w4-general-note-witnessunreviewed · printed
tc_opening_lintel_clause_partial
ALL OPENINGS IN T.C. PARTITIONS TO HAVE CHANNELS LINTELS / SAME WIDTH AS T.C. UNLESS NOTED OTHERWISECHANNELS versus CHANNEL wording/gauge remains uncertain. Do not promote partial apparent type to exact construction. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: ALL OPENINGS IN T.C. PARTITIONS TO HAVE CHANNELS LINTELS / SAME WIDTH AS T.C. UNLESS NOTED OTHERWISE
CHANNELS versus CHANNEL wording/gauge remains uncertain. Do not promote partial apparent type to exact construction. Source-local printed/observed evidence only. Crop rectangle locates the actually reviewed region, not a physical boundary; no geometric acceptance.
plangap1012k-w4-general-note-witnessverified · printed
tc-opening-channel-lintel-clause
ALL OPENINGS IN T.C. PARTITIONS TO HAVE CHANNEL LINTELS SAME WIDTH AS T.C. UNLESS NOTED OTHERWISE.CHANNEL LINTELS is readable; equality-of-width construction relationship only. Steel channel section/gauge and span are not printed here. Source-local original-layer witness only; no installation, quantity or geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: ALL OPENINGS IN T.C. PARTITIONS TO HAVE CHANNEL LINTELS SAME WIDTH AS T.C. UNLESS NOTED OTHERWISE.
CHANNEL LINTELS is readable; equality-of-width construction relationship only. Steel channel section/gauge and span are not printed here. Source-local original-layer witness only; no installation, quantity or geometric acceptance.
plangap1012k-w4-general-note-witnessverified · printed
cabinet-partition-gc-exception
WHERE TELEPHONE AND ELECTRIC CABINETS OCCUR IN T.C. PARTITIONS, SAME TO BE OF G.C.Retain literal G.C.; no abbreviation expansion or accepted material build-up. Source-local original-layer witness only; no installation, quantity or geometric acceptance.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: WHERE TELEPHONE AND ELECTRIC CABINETS OCCUR IN T.C. PARTITIONS, SAME TO BE OF G.C.
Retain literal G.C.; no abbreviation expansion or accepted material build-up. Source-local original-layer witness only; no installation, quantity or geometric acceptance.
plangap1012k-w4-general-note-witnessverified · printed
structural_reinforcement_reference_continuation
FOR METAL REINFORCEMENT NOT SHOWN SEE STRUCTURAL DWGSIMG1207 full-width witness supplies DWGS continuation clipped in IMG1209 20261012c record. Prior clipped record retained separately; no drawing number or member geometry inferred.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: FOR METAL REINFORCEMENT NOT SHOWN SEE STRUCTURAL DWGS
IMG1207 full-width witness supplies DWGS continuation clipped in IMG1209 20261012c record. Prior clipped record retained separately; no drawing number or member geometry inferred.
plangap1012k-w4-general-note-witnessverified · printed
window_jamb_head_exception_continuation
WINDOWS TO HAVE PLASTER JAMBS AND HEADS UNLESS NOTED / OTHERWISEIndependent IMG1207 witness resolves clipped exception continuation in IMG1209 prior note. Default instruction alone establishes neither exceptions nor layer thickness.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: WINDOWS TO HAVE PLASTER JAMBS AND HEADS UNLESS NOTED / OTHERWISE
Independent IMG1207 witness resolves clipped exception continuation in IMG1209 prior note. Default instruction alone establishes neither exceptions nor layer thickness.
plangap1012k-w4-general-note-witnessunreviewed · printed
tile_partition_opening_lintel_note_partial
ALL OPENINGS IN T.C. PARTITIONS TO HAVE ... LINTELS / ... WITH ... / WHERE TELEPHONE AND ELECTRIC CABINETS OCCUR IN T.C. / PARTITIONS, SAME TO BE OF G.C.Previously omitted pre-reinforcement note. Lintel type/continuation, cabinet abbreviation and terminal material abbreviation remain unreadable; literal uncertain letters retained without expanding them into specified construction.
IMG_1207 · W-4 · Locate on drawing ↗Drawing notation: ALL OPENINGS IN T.C. PARTITIONS TO HAVE ... LINTELS / ... WITH ... / WHERE TELEPHONE AND ELECTRIC CABINETS OCCUR IN T.C. / PARTITIONS, SAME TO BE OF G.C.
Previously omitted pre-reinforcement note. Lintel type/continuation, cabinet abbreviation and terminal material abbreviation remain unreadable; literal uncertain letters retained without expanding them into specified construction.