profile10 flanking materials
MarbleBoth sides of profile10 labelled marble; no stone thickness inferred.
Drawing notation: Marble
Both sides of profile10 labelled marble; no stone thickness inferred.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: Typical interior door jambs and trim schedule
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
Both sides of profile10 labelled marble; no stone thickness inferred.
Drawing notation: Marble
Both sides of profile10 labelled marble; no stone thickness inferred.
Wood label beside profile11; species unresolved.
Drawing notation: Wood
Wood label beside profile11; species unresolved.
Yellow tick is aligned with corrections-noted line.
Drawing notation: APPROVED WITH CORRECTIONS NOTED
Yellow tick is aligned with corrections-noted line.
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
Drawing notation: 5-13-32
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
1 count
Typical group quantity only; no installed door identity.
Drawing notation: BASEMENT 1 SET
Typical group quantity only; no installed door identity.
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
Drawing notation: ALL FIR
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
2 count
Schedule group only.
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
Drawing notation: ALL P.W.O.
Selected printed property of depicted assembly or schedule group; no physical room geometry or installed instance assignment.
1 sets
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 1 [ditto from1 SET]
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
36 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 3′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
84 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 7′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: ALL MAH.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
1 sets
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 1 [ditto from1 SET]
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
36 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 3′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
84 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 7′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: ALL MAH.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
1 sets
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 1 [ditto from1 SET]
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
36 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 3′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
84 in
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: 7′-0″
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Drawing notation: ALL MAH.
Corridor-to-toilet printed schedule group; floor association only, installed opening identity unresolved.
Numeric value unresolved
Fraction and endpoints require crop; type 11 is not installed opening ID.
Fraction and endpoints require crop; type 11 is not installed opening ID.
Numeric value unresolved
Two-axis size fractions unresolved.
Two-axis size fractions unresolved.
Numeric value unresolved
Two-axis fractions unresolved; set count/material already closed.
Two-axis fractions unresolved; set count/material already closed.
First-pass property only; remaining detail and endpoint/component associations require review.
Drawing notation: TYPICAL INTERIOR DOOR JAMBS AND TRIM
First-pass property only; remaining detail and endpoint/component associations require review.
2 in
First-pass property only; remaining detail and endpoint/component associations require review.
Drawing notation: Jambs to be made from 2″ stock as per specification
First-pass property only; remaining detail and endpoint/component associations require review.
First-pass property only; remaining detail and endpoint/component associations require review.
Drawing notation: CORRIDOR TO TOILET
First-pass property only; remaining detail and endpoint/component associations require review.
First-pass property only; remaining detail and endpoint/component associations require review.
Drawing notation: NO TRANSOM FOR D.A. DOOR IN CORRIDOR ON 6TH FL.
First-pass property only; remaining detail and endpoint/component associations require review.
White basement double acting row; records literal width/height code only. Count and ALL FIR are reused from older verified properties. No inch marks visible on size code; plausible door sizes do not supply units.
Drawing notation: BASEMENT. 1 SET DR OPNG 2-11 x 6-11½ ALL FIR.
White basement double acting row; records literal width/height code only. Count and ALL FIR are reused from older verified properties. No inch marks visible on size code; plausible door sizes do not supply units.
Separate white sixth-floor double acting row; preserves literal two-axis code. Existing count and material remain separate, no unit inference or physical opening geometry.
Drawing notation: SIXTH 2 SETS DR OPNG 2-11 x 6-11½ ALL P.W.O.
Separate white sixth-floor double acting row; preserves literal two-axis code. Existing count and material remain separate, no unit inference or physical opening geometry.
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.