parallel-img1320-framingverified · printed
assignment
7TH FLOOR CEILING & 8TH FLOOR FRAMING PLANSelected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1320-framingverified · printed
truss_reference
FOR TRUSS DETAILS SEE DRAWING NO.410Selected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1320-framingverified · printed
ceiling_fireproofing
6",12" AND 15" CHANNELS FOR CEILING NEED NOT BE FIREPROOFED WITH CONCRETESelected visible source evidence only; partial review, applies to depicted assembly.
IMG_1320 · W-406 · Locate on drawing ↗Drawing notation: 6",12" AND 15" CHANNELS FOR CEILING NEED NOT BE FIREPROOFED WITH CONCRETE
Selected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1320-framingverified · printed
ceiling_channel_depth_6
6" CHANNELS6 in
Channel sizes in fireproofing exception; individual member placement unresolved.
parallel-img1320-framingverified · printed
ceiling_channel_depth_12
12" CHANNELS12 in
Channel sizes in fireproofing exception; individual member placement unresolved.
parallel-img1320-framingverified · printed
ceiling_channel_depth_15
15" CHANNELS15 in
Channel sizes in fireproofing exception; individual member placement unresolved.
parallel-img1320-framingunreviewed · printed
beam_elevation_reference
NOTE: BEAM ELEVATIONS ARE [datum wording unresolved]Selected visible source evidence only; partial review, applies to depicted assembly.
IMG_1320 · W-406 · Locate on drawing ↗Drawing notation: NOTE: BEAM ELEVATIONS ARE [datum wording unresolved]
Selected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1320-framingverified · printed
beam_elevation_reference_face
BEAM ELEVATIONS ARE TO TOP OF STEELResolves previously unresolved note wording; prior candidate record retained.
parallel-img1320-framingverified · printed
beam_elevation_reference_datum
ARE RELATIVE TO FINISHED 7TH FLOOR ELEV. 171.75Printed datum wording. Unit and individual beam elevation mapping remain unestablished.
IMG_1320 · W-406 · Locate on drawing ↗Drawing notation: ARE RELATIVE TO FINISHED 7TH FLOOR ELEV. 171.75
Printed datum wording. Unit and individual beam elevation mapping remain unestablished.
parallel-img1320-framingverified · printed
fan_room_machine_room_companion_reference
NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 405, 407 & 408Cross-sheet dependency only; no geometry or instance placement inferred.
IMG_1320 · W-406 · Locate on drawing ↗Drawing notation: NOTE: FOR FRAMING OF FAN ROOM AND ELEVATOR MACHINE ROOM NOT SHOWN ON THIS DRAWING SEE DRAWINGS NOS. 405, 407 & 408
Cross-sheet dependency only; no geometry or instance placement inferred.