assignment
7TH FLOOR FRAMING PLANSelected visible source evidence only; partial review, applies to depicted assembly.
Drawing notation: 7TH FLOOR FRAMING PLAN
Selected visible source evidence only; partial review, applies to depicted assembly.
Every dimension belongs to an object and a drawing. Original room numbers, object marks, printed values and source regions stay together—even when the answer is unresolved.
464 of 464 photographs have extraction records, containing 27,517 properties. Initial image review is not exhaustive extraction: 0 photographs have passed the full-region check. 66 numbered sheets are reconciled. Modeling and architectural registration are separate work; these counts do not establish a complete building.
Download the structured register (JSON)Object: Seventh-floor framing
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
Selected visible source evidence only; partial review, applies to depicted assembly.
Drawing notation: 7TH FLOOR FRAMING PLAN
Selected visible source evidence only; partial review, applies to depicted assembly.
Selected visible source evidence only; partial review, applies to depicted assembly.
Drawing notation: FLOOR ELEVATION 173.75 ABOVE THIS LINE
Selected visible source evidence only; partial review, applies to depicted assembly.
Selected visible source evidence only; partial review, applies to depicted assembly.
Drawing notation: FLOOR ELEVATION 171.75 BELOW THIS LINE
Selected visible source evidence only; partial review, applies to depicted assembly.
Selected visible source evidence only; partial review, applies to depicted assembly.
Drawing notation: FLOOR LOAD [unresolved] / LOWER SLAB [unresolved] EXCEPT AS NOTED
Selected visible source evidence only; partial review, applies to depicted assembly.
Selected visible source evidence only; partial review, applies to depicted assembly.
Selected visible source evidence only; partial review, applies to depicted assembly.
4 in
Printed floor-fill note; regional exceptions and material specification unestablished. Does not establish total slab thickness.
Drawing notation: FLOOR FILL 4"
Printed floor-fill note; regional exceptions and material specification unestablished. Does not establish total slab thickness.
Printed reference face for elevations on this structural framing sheet.
Drawing notation: BEAM ELEVATIONS ARE TO TOP OF STEEL
Printed reference face for elevations on this structural framing sheet.
Preserve datum notation without inventing a unit or assigning the lower regional floor.
Drawing notation: RELATIVE TO FINISHED FLOOR ELEVATION 173.75
Preserve datum notation without inventing a unit or assigning the lower regional floor.
Printed dependency points to slab-detail sheet W413 (IMG_1327); does not verify applicability of every generic detail.
Drawing notation: FOR DETAILS OF SLABS SEE SH. No 413
Printed dependency points to slab-detail sheet W413 (IMG_1327); does not verify applicability of every generic detail.
4.5 in
Printed local default; exceptions and slab field boundaries require registration.
Drawing notation: LOWER SLAB 4½″
Printed local default; exceptions and slab field boundaries require registration.
Bracket qualifies both floor fill 4″ and lower slab 4½″; prior fill reading retained.
Drawing notation: EXCEPT AS NOTED
Bracket qualifies both floor fill 4″ and lower slab 4½″; prior fill reading retained.
Source inventory is separate from the floor filters above. Select one drawing to inspect it; no drawing set is preloaded.