Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1319-courtbeamverified · printed
assignment
LIGHT COURT WALL BEAMS AT RAISED PORTION OF 7TH FLOOR EL.173.75Selected visible source evidence only; partial review, applies to depicted assembly.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: LIGHT COURT WALL BEAMS AT RAISED PORTION OF 7TH FLOOR EL.173.75
Selected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1319-courtbeamverified · printed
companion_reference
SECTION OF LIGHT COURT WALL BEAMS AT EL.171.75 TO BE SAME AS COURT WALL SECTIONS ON 3RD FLOOR PLAN STRUCTURAL DWG.NO.402Selected visible source evidence only; partial review, applies to depicted assembly.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: SECTION OF LIGHT COURT WALL BEAMS AT EL.171.75 TO BE SAME AS COURT WALL SECTIONS ON 3RD FLOOR PLAN STRUCTURAL DWG.NO.402
Selected visible source evidence only; partial review, applies to depicted assembly.
parallel-img1319-courtbeamverified · printed
fill_dimension_3
3″ × 2″ × 5″ FILLS5 in
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: 3″ × 2″ × 5″ FILLS
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
parallel-img1319-courtbeamverified · printed
fill_dimension_1
3″ × 2″ × 5″ FILLS3 in
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: 3″ × 2″ × 5″ FILLS
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
parallel-img1319-courtbeamverified · printed
fill_dimension_2
3″ × 2″ × 5″ FILLS2 in
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: 3″ × 2″ × 5″ FILLS
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
parallel-img1319-courtbeamverified · printed
fill_spacing
3′-0″ O.C.3 ft
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: 3′-0″ O.C.
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
parallel-img1319-courtbeamverified · printed
rivets_per_fill_point
TWO RIVETS AT EACH POINT2 count
Type-local rivets per fill point only.
parallel-img1319-courtbeamverified · printed
rivet_head_treatment
C.S.K ON OUTSIDEPrinted source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: C.S.K ON OUTSIDE
Printed source-local detail/type property only; no installed instance, coordinates, quantity or manufactured rolled profile inferred.
parallel-img1319-courtbeamverified · printed
bottom_angle_notation
7″ × 3½″ × ⅜″ LLiteral bottom-angle designation in this raised seventh-floor section; independent of floor-wide continuity rules and not a manufactured rolled profile.
IMG_1319 · W-405 · Locate on drawing ↗Drawing notation: 7″ × 3½″ × ⅜″ L
Literal bottom-angle designation in this raised seventh-floor section; independent of floor-wide continuity rules and not a manufactured rolled profile.