Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1265-detailverified · printed
drawing_title
STAIR DETAILS — TYPICAL FOR STAIRS A B C D E F G & HPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
drawing_scale
3" = 1'-0"Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
landing_riser_applicability
TYPICAL SECTION THRU LANDING AND RISERS — FOR STAIRS B D & EPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: TYPICAL SECTION THRU LANDING AND RISERS — FOR STAIRS B D & E
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
two_riser_condition
TYPICAL SECTION OF LANDINGS WHERE TWO RISERS OCCURPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
window_condition
TYPICAL SECTION AT WINDOWPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · observed
newel_conditions
Typical sections between newel posts at landings / floor levelsPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Typical sections between newel posts at landings / floor levels
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · printed
wall_rail
WALL HAND RAIL AND BRACKETSPartial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailneeds-review · observed
handwritten_annotation
Red annotation/markup in central newel detail [unreadable]Partial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Red annotation/markup in central newel detail [unreadable]
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailverified · observed
prior_report
Existing stair-w228-typical-details-first.md uses IMG_1122; source-dependent sizes not copied to IMG_1265 without crop verificationPartial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Existing stair-w228-typical-details-first.md uses IMG_1122; source-dependent sizes not copied to IMG_1265 without crop verification
Partial drawing/detail evidence only; no installed geometry or count established.
parallel-img1265-detailunreviewed · observed
fine_dimensions
Tread/riser, plate/channel/tube, bracket, weld/bolt and rail profiles unresolved at locator sizeNumeric value unresolved
Partial drawing/detail evidence only; no installed geometry or count established.
IMG_1265 · W-228 · Locate on drawing ↗Drawing notation: Tread/riser, plate/channel/tube, bracket, weld/bolt and rail profiles unresolved at locator size
Partial drawing/detail evidence only; no installed geometry or count established.