Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1157-inspectorverified · printed
room_assignment
POST OFFICE INSPECTORS TOILET ROOM - 223Selected source evidence only; partial locator review. Applies only to depicted assembly.
parallel-img1157-inspectorverified · observed
fixtures
Lavatory and W.C. compartment shown beside janitor closetSelected source evidence only; partial locator review. Applies only to depicted assembly.
IMG_1157 · W-235 · Locate on drawing ↗Drawing notation: Lavatory and W.C. compartment shown beside janitor closet
Selected source evidence only; partial locator review. Applies only to depicted assembly.
parallel-img1157-inspectorunreviewed · printed
room_dimensions
UnresolvedNumeric value unresolved
Selected source evidence only; partial locator review. Applies only to depicted assembly.
parallel-img1157-inspectorverified · printed
section_bb_upper_wall_finish
PLASTERSection B-B upper field leader, distinct from metal-lath furring backing and lower marble label. Thickness and installed finish unknown.
IMG_1157 · W-235 · Locate on drawing ↗Drawing notation: PLASTER
Section B-B upper field leader, distinct from metal-lath furring backing and lower marble label. Thickness and installed finish unknown.
Calculated from: detail-20261011k-1157-1
parallel-img1157-inspectorverified · printed
section_bb_lower_wall_finish
MARBLEPrinted vertical marble label in lower section field. No wainscot height or marble grade/color inferred.
parallel-img1157-inspectorverified · printed
section-wall-construction
METAL LATH FURRING & PLASTERDepicted source-local component only; no installed quantity, room geometry or world placement inferred.
parallel-img1157-inspectorverified · printed
section-door-material
FLUSH WOOD DOORDepicted source-local component only; no installed quantity, room geometry or world placement inferred.
parallel-img1157-inspectorunresolved · printed
door-thickness
UnresolvedNumeric value unresolved
Door thickness fraction not secure; source-local section only.
parallel-img1157-inspectorverified · printed
shower-pan-note
TILE FL. LEAD PAN UNDERApplies only to depicted source-local assembly; no exact room geometry or installed state established.
parallel-img1157-inspectorverified · printed
shower-seat-material
WOOD SEATApplies only to depicted source-local assembly; no exact room geometry or installed state established.
parallel-img1157-inspectorverified · printed
shower-stall-clear-width
2'-6"30 in
Applies only to depicted source-local assembly; no exact room geometry or installed state established.
parallel-img1157-inspectorverified · printed
janitor-finish-schedule
FINISH NO. 66 finish-schedule-number
Applies only to depicted source-local assembly; no exact room geometry or installed state established.
parallel-img1157-inspectorverified · printed
plan-compartment-partition-thickness
1⅛"1.125 in
Printed plan thickness at thin compartment partition; numeric thickness does not establish rough versus finished witness faces.
parallel-img1157-inspectorverified · printed
section-marble-wainscot-height
6'-0" MARBLE72 in
Section B-B floor-to-wainscot-top local witness; no whole-room ceiling height.
parallel-img1157-inspectorverified · printed
plan-horizontal-inner-face-witness
9'-6"114 in
Inspector-room223 horizontal witness between drawn inside wall lines; exact plaster/marble finish-face class still unreviewed; not world geometry.
IMG_1157 · W-235 · Locate on drawing ↗Drawing notation: 9'-6"
Inspector-room223 horizontal witness between drawn inside wall lines; exact plaster/marble finish-face class still unreviewed; not world geometry.
parallel-img1157-inspectorverified · printed
compartment-depth-witness
4'-0"48 in
Orthogonal compartment witness from street-front wall side to partition side; reference surface class unresolved.
parallel-img1157-inspectorunreviewed · observed
partition-face-classification
UnresolvedThin compartment partition is drawn; rough/finished face and thickness cannot be securely established from this crop.