Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1111-assemblyverified · printed
section_EE
SECTION E-ESelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
section_DD
SECTION D-DSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
section_BB
SECTION B-BSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
section_CC
SECTION C-CSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
second_floor_plan
2ND FLOOR PLANSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
gate_type
COLLAPSIBLE GATESelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
plaster_finish
PLASTERSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyverified · printed
tile_base
TILE BASESelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1111-assemblyunreviewed · printed
bracket_spacing_note_unresolved
[HD. RAIL BRACKETS SHOULD BE SPACED NOT OVER ... O.C.; numeric glyph too small]Numeric value unresolved
Unresolved locator reading; numeric value withheld.
parallel-img1111-assemblyunreviewed · printed
section_dimension_chains_unresolved
[section heights and stair details need finer crops]Numeric value unresolved
Unresolved locator reading; numeric value withheld.
parallel-img1111-assemblyverified · printed
central_section_second_to_third
11′6″138 in
Outermost central-section vertical witness between labeled second and third floor reference lines. Source-local only; no accepted installed geometry.
IMG_1111 · W-221 · Locate on drawing ↗Drawing notation: 11′6″
Outermost central-section vertical witness between labeled second and third floor reference lines. Source-local only; no accepted installed geometry.
parallel-img1111-assemblyverified · printed
central_section_first_to_second
21′0″252 in
Outermost central-section vertical witness from first-floor reference to second-floor reference. Source-local only; no accepted installed geometry.
IMG_1111 · W-221 · Locate on drawing ↗Drawing notation: 21′0″
Outermost central-section vertical witness from first-floor reference to second-floor reference. Source-local only; no accepted installed geometry.
parallel-img1111-assemblyverified · printed
central_section_basement_to_first
13′0″156 in
Outermost central-section basement-to-first-floor vertical witness. Source-local only; no accepted installed geometry.
parallel-img1111-assemblyverified · printed
central_upper_landing_to_second
7′2″86 in
Central section local vertical witness from upper intermediate landing surface reference toward second-floor line; complete rough/finish classification remains open. Source-local only; no accepted installed geometry.
IMG_1111 · W-221 · Locate on drawing ↗Drawing notation: 7′2″
Central section local vertical witness from upper intermediate landing surface reference toward second-floor line; complete rough/finish classification remains open. Source-local only; no accepted installed geometry.
parallel-img1111-assemblyverified · printed
central_first_to_landing
13′3″159 in
Central section local vertical witness between first-floor and intermediate landing surface references. Source-local only; no accepted installed geometry.
IMG_1111 · W-221 · Locate on drawing ↗Drawing notation: 13′3″
Central section local vertical witness between first-floor and intermediate landing surface references. Source-local only; no accepted installed geometry.
parallel-img1111-assemblyverified · printed
handrail_bracket_maximum_spacing
[initial letters clipped] RAIL BRACKETS SHOULD BE SPACED NOT OVER 6′0″ O.C.6 ft
Original white printed drawing layer. Same bottom note whose maximum-spacing glyph was previously null. Beginning of line is clipped at photograph edge but terminal numeric clause is legible.
IMG_1111 · W-221 · Locate on drawing ↗Drawing notation: [initial letters clipped] RAIL BRACKETS SHOULD BE SPACED NOT OVER 6′0″ O.C.
Original white printed drawing layer. Same bottom note whose maximum-spacing glyph was previously null. Beginning of line is clipped at photograph edge but terminal numeric clause is legible.