Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1110-assemblyverified · printed
sheet_subject
STAIR A BASEMENT 1ST & 2ND FLOORSSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: STAIR A BASEMENT 1ST & 2ND FLOORS
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
second_floor_plan
2ND FLOOR PLANSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: 2ND FLOOR PLAN
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
gate_type
COLLAPSIBLE GATESelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: COLLAPSIBLE GATE
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
gate_plan_label
PLANSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: PLAN
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
section_AA
SECTION A-ASelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: SECTION A-A
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
section_DD
SECTION D-DSelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: SECTION D-D
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
section_EE
SECTION E-ESelected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: SECTION E-E
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyverified · printed
companion_reference
SEE DRAWING NO. 228Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
IMG_1110 · Locate on drawing ↗Drawing notation: SEE DRAWING NO. 228
Selected legible locator evidence; partial assembly-local scope; no complete dimension chain or model assignment.
parallel-img1110-assemblyunreviewed · printed
bracket_spacing_unresolved
[handrail bracket spacing note clipped at bottom]Numeric value unresolved
Unresolved locator reading; numeric value withheld.
parallel-img1110-assemblyunreviewed · printed
remaining_sections_dimensions
[riser heights, landing levels, gate bar sizes and shaft dimensions unresolved]Numeric value unresolved
Unresolved locator reading; numeric value withheld.
IMG_1110 · Locate on drawing ↗Drawing notation: [riser heights, landing levels, gate bar sizes and shaft dimensions unresolved]
Unresolved locator reading; numeric value withheld.
parallel-img1110-assemblyverified · printed
bracket_max_spacing
[initial wording photograph-edge clipped] ... SPACED NOT OVER 6′0″ O.C.6 ft
Bottom handrail-bracket maximum-spacing glyph; same clipped bottom-note locus as prior null. The numerical end of the note is readable although earlier lettering is cut. Source-local only; no accepted installed geometry.
IMG_1110 · Locate on drawing ↗Drawing notation: [initial wording photograph-edge clipped] ... SPACED NOT OVER 6′0″ O.C.
Bottom handrail-bracket maximum-spacing glyph; same clipped bottom-note locus as prior null. The numerical end of the note is readable although earlier lettering is cut. Source-local only; no accepted installed geometry.