Object: W220 registry/service window, metal columns and work-room scale-pit details
Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1107-detailverified · printed
work_room_wall
Part elevation of south wall of work roomPartial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
registry_location
Work room side of Registry & C.O.D. roomsPartial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
superintendent_location
Work room side of superintendent of mails roomPartial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
service_window_detail
Scale details of service window & glazed partitions in work roomPartial detail-level evidence; installed quantities and geometry not established.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: Scale details of service window & glazed partitions in work room
Partial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
column_construction
Details of metal covering for interior columnsPartial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
window_type
STAMP WINDOW CAGESPartial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · observed
pit_detail
Details of work room scale pit; plan, Section A-A, Section B-B, Details E/FPartial detail-level evidence; installed quantities and geometry not established.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: Details of work room scale pit; plan, Section A-A, Section B-B, Details E/F
Partial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailunreviewed · observed
pit_dimensions
Numerous scale-pit dimensions and construction notes blurryNumeric value unresolved
Partial detail-level evidence; installed quantities and geometry not established.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: Numerous scale-pit dimensions and construction notes blurry
Partial detail-level evidence; installed quantities and geometry not established.
parallel-img1107-detailverified · printed
column-expansion-joint
EXPANSION JOINTSource-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: EXPANSION JOINT
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
parallel-img1107-detailunreviewed · printed
column-material-note
NOTE: INTERIOR COLUMNS WHICH HAVE NEITHER PLUMBING DUCTS SHALL HAVE THE PAINTED GALV. IRON CASING WHICH IS NOT FURRED [partial reading]Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: NOTE: INTERIOR COLUMNS WHICH HAVE NEITHER PLUMBING DUCTS SHALL HAVE THE PAINTED GALV. IRON CASING WHICH IS NOT FURRED [partial reading]
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
parallel-img1107-detailverified · printed
partition-glazing
CLEAR GLASSSource-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: CLEAR GLASS
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
parallel-img1107-detailverified · printed
scale-pit-section-B-inner-width-witness
6′-0″72 in
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 6′-0″
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
parallel-img1107-detailverified · printed
scale-pit-section-B-channel
6″ CHANNEL6 in
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 6″ CHANNEL
Source-local additive printed detail evidence; no installed quantity, operating clear dimensions, room geometry or accepted placement.
parallel-img1107-detailverified · printed
column-section-steel-bar-thickness
⅜″ × 1½″ STEEL BAR0.375 in
Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Section steel bar first dimension; source-local member only.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: ⅜″ × 1½″ STEEL BAR
Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Section steel bar first dimension; source-local member only.
parallel-img1107-detailverified · printed
column-section-steel-bar-width
⅜″ × 1½″ STEEL BAR1.5 in
Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Second dimension of same section steel bar.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: ⅜″ × 1½″ STEEL BAR
Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Second dimension of same section steel bar.
parallel-img1107-detailverified · printed
column-pipe-duct-furring-cover-relationship
NOTE: INTERIOR COLUMNS WHICH ARE FURRED TO FORM PIPE DUCTS SHALL HAVE THE FURRING & METAL COVER IN A MANNER SIMILAR TO THAT SHOWN ABOVE FOR COLUMNS NOT FURRED.Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Master-crop transcription supersedes earlier partial interpretation. It specifies analogous furring/metal-cover manner for duct columns; no painted galvanised material or opposite plaster-only rule established.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: NOTE: INTERIOR COLUMNS WHICH ARE FURRED TO FORM PIPE DUCTS SHALL HAVE THE FURRING & METAL COVER IN A MANNER SIMILAR TO THAT SHOWN ABOVE FOR COLUMNS NOT FURRED.
Source-local printed detail or selected note only. No installed quantity, clear opening, building placement or accepted geometry established. Master-crop transcription supersedes earlier partial interpretation. It specifies analogous furring/metal-cover manner for duct columns; no painted galvanised material or opposite plaster-only rule established.
parallel-img1107-detailverified · printed
column_casing_sheet_steel_thickness
1/8" SHEET STEEL0.125 in
Leader at top of steel wainscot section specifies sheet steel. Assembly-local casing property; does not specify wall thickness or installed column quantity.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 1/8" SHEET STEEL
Leader at top of steel wainscot section specifies sheet steel. Assembly-local casing property; does not specify wall thickness or installed column quantity.
parallel-img1107-detailverified · printed
column_casing_adjacent_layer_material
PLASTERSeparate plaster leader at column casing section. No numeric plaster thickness readable and no finish extrapolation to other objects.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: PLASTER
Separate plaster leader at column casing section. No numeric plaster thickness readable and no finish extrapolation to other objects.
parallel-img1107-detailneeds-review · printed
column_casing_corner_joint_designation_unresolved
[fraction resembles 3/16] × 2½ [angle symbol; confirmation pending]Numeric value unresolved
Plan of corner joint token is more legible in the master crop but the first fraction and symbol remain uncertain. Neither dimension promoted; section steel-bar record remains separate.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: [fraction resembles 3/16] × 2½ [angle symbol; confirmation pending]
Plan of corner joint token is more legible in the master crop but the first fraction and symbol remain uncertain. Neither dimension promoted; section steel-bar record remains separate.
parallel-img1107-detailneeds-review · printed
column_cover_elevation_height_witness_unresolved
[appears 7′-11″; token confirmation pending]Numeric value unresolved
Vertical witness alongside column-cover elevation. Not a floor height; unresolved token and endpoints require companion confirmation.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: [appears 7′-11″; token confirmation pending]
Vertical witness alongside column-cover elevation. Not a floor height; unresolved token and endpoints require companion confirmation.
parallel-img1107-detailverified · printed
column_casing_corner_joint_first_size
3/16 × 2½ [angle symbol]0.1875 unlabeled-drawing-number
First numeric token of corner-joint designation. The crop does not securely establish an explicit unit token, so retain the number separately from any inch interpretation. Angle symbol/type authority and fabrication geometry require further confirmation. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 3/16 × 2½ [angle symbol]
First numeric token of corner-joint designation. The crop does not securely establish an explicit unit token, so retain the number separately from any inch interpretation. Angle symbol/type authority and fabrication geometry require further confirmation. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
parallel-img1107-detailverified · printed
column_casing_corner_joint_second_size
3/16 × 2½ [angle symbol]2.5 unlabeled-drawing-number
Second numeric token of same corner-joint designation; explicit unit remains unconfirmed. This is not a separate member or installed quantity. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 3/16 × 2½ [angle symbol]
Second numeric token of same corner-joint designation; explicit unit remains unconfirmed. This is not a separate member or installed quantity. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
parallel-img1107-detailverified · printed
column_cover_elevation_height_witness
7′-11″95 in
Printed vertical witness alongside casing elevation; endpoints are drawing limits, not accepted finished-floor elevations. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 7′-11″
Printed vertical witness alongside casing elevation; endpoints are drawing limits, not accepted finished-floor elevations. Source-local evidence only; no installed count, accepted geometry, world transform or governing revision.
parallel-img1107-detailverified · printed
scale_pit_plan_transverse_witness
6′-0″72 in
Plan transverse witness across drawn inner side boundaries. Distinct from existing Section B witness. Source-local only; not accepted installed geometry.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 6′-0″
Plan transverse witness across drawn inner side boundaries. Distinct from existing Section B witness. Source-local only; not accepted installed geometry.
parallel-img1107-detailverified · printed
scale_pit_plan_longitudinal_witness
7′-10″94 in
Overall longitudinal plan witness; no installed clear-pit acceptance. Source-local only; not accepted installed geometry.
parallel-img1107-detailverified · printed
scale_pit_plan_upper_longitudinal_segment
2′-10″34 in
Upper segment on plan longitudinal chain to intermediate member. Source-local only; not accepted installed geometry.
parallel-img1107-detailverified · printed
scale_pit_plan_lower_longitudinal_segment
5′-0″60 in
Lower segment on plan longitudinal chain from intermediate member. Source-local only; not accepted installed geometry.
parallel-img1107-detailverified · printed
scale_pit_detail_e_horizontal_witness
1′-0″12 in
Horizontal detail E witness; precise faces and load-bearing interpretation unresolved. Source-local only; not accepted installed geometry.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: 1′-0″
Horizontal detail E witness; precise faces and load-bearing interpretation unresolved. Source-local only; not accepted installed geometry.
parallel-img1107-detailverified · printed
scale_pit_structural_work_scope
NOTE: ALL CHANNELS, ANGLES, PLATES ETC. SHOWN ABOVE ARE FURNISHED & INSTALLED UNDER THE STRUCTURAL WORK. SEE STRUCTURAL DRAWINGS.Same-image scope note below scale-pit title; coordination requirement, not proof of installation. Source-local only; not accepted installed geometry.
IMG_1107 · W-220 · Locate on drawing ↗Drawing notation: NOTE: ALL CHANNELS, ANGLES, PLATES ETC. SHOWN ABOVE ARE FURNISHED & INSTALLED UNDER THE STRUCTURAL WORK. SEE STRUCTURAL DRAWINGS.
Same-image scope note below scale-pit title; coordination requirement, not proof of installation. Source-local only; not accepted installed geometry.