Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1078-assemblyverified · printed
sash-material
STEEL SASHSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: STEEL SASH
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyverified · printed
glazing
PLATE GLASSSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: PLATE GLASS
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyverified · printed
floor-datum
LINE OF FIN. 4TH FL.Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: LINE OF FIN. 4TH FL.
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyverified · printed
flashing-material
LEAD FLASHING & COUNTER FLASHINGSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: LEAD FLASHING & COUNTER FLASHING
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyverified · printed
floor-ceiling-finish
FURRED CEILING / METAL LATH & PL.Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: FURRED CEILING / METAL LATH & PL.
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyunreviewed · printed
stone-joint-reference
[note on bottom-of-stone dimension references; fine wording unresolved]Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: [note on bottom-of-stone dimension references; fine wording unresolved]
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
parallel-img1078-assemblyverified · printed
stone_dimension_reference_prefix
DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONEPrinted source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Only readable prefix adopted. Terminal joint clause and earlier ALL JOINTS transcription remain separately unresolved; no joint thickness inferred.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONE
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Only readable prefix adopted. Terminal joint clause and earlier ALL JOINTS transcription remain separately unresolved; no joint thickness inferred.
parallel-img1078-assemblyillegible · printed
stone_dimension_note_joint_fraction
AND INCLUDE A [fraction] JOINT [terminal clause not adopted]Numeric value unresolved
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Looks like singular joint with fractional token; fraction withheld. This is not a verified correction to earlier ALL JOINTS wording.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: AND INCLUDE A [fraction] JOINT [terminal clause not adopted]
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Looks like singular joint with fractional token; fraction withheld. This is not a verified correction to earlier ALL JOINTS wording.
parallel-img1078-assemblyverified · printed
section-bb-membrane-material
MEMBRANE WATERPROOFINGLeader at fifth-floor connection; repeated at fourth/third levels, no continuous wall-thickness conclusion. Source-local detail/type only; no installed quantity or physical placement.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: MEMBRANE WATERPROOFING
Leader at fifth-floor connection; repeated at fourth/third levels, no continuous wall-thickness conclusion. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1078-assemblyverified · printed
section-bb-third-floor-stone-fixing
DOWEL ANCHORSThird-floor stone fixing leader only; sizes/counts unresolved. Source-local detail/type only; no installed quantity or physical placement.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: DOWEL ANCHORS
Third-floor stone fixing leader only; sizes/counts unresolved. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1078-assemblyverified · printed
section-bb-third-floor-inner-backing-thickness
2″ T.C. TILE2 in
Thin inner backing callout; not total exterior wall. Source-local detail/type only; no installed quantity or physical placement.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: 2″ T.C. TILE
Thin inner backing callout; not total exterior wall. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1078-assemblyverified · printed
section-bb-fourth-floor-selected-vertical-span
1′-6″18 in
Printed short floor-band line near fourth floor; visible endpoints stone-band floor zone, exact finish/structural face classification remains open. Source-local detail/type only; no installed quantity or physical placement.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: 1′-6″
Printed short floor-band line near fourth floor; visible endpoints stone-band floor zone, exact finish/structural face classification remains open. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1078-assemblyillegible · printed
section-bb-floor-to-ceiling-fraction-unresolved
[9′-11… fractional suffix unresolved]Numeric value unresolved
No numeric value chosen from ambiguous suffix. Source-local detail/type only; no installed quantity or physical placement.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: [9′-11… fractional suffix unresolved]
No numeric value chosen from ambiguous suffix. Source-local detail/type only; no installed quantity or physical placement.
parallel-img1078-assemblyverified · printed
bb-fifth-floor-tile-backing
3″ T.C. TILE3 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed fifth-floor backing note; leader does not establish a complete wall chain.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: 3″ T.C. TILE
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed fifth-floor backing note; leader does not establish a complete wall chain.
parallel-img1078-assemblyverified · printed
bb-fourth-floor-tile-backing
3″ T.C. TILE3 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate fourth-floor backing note; do not merge with verified third-floor 2-inch note.
IMG_1078 · W-207 · Locate on drawing ↗Drawing notation: 3″ T.C. TILE
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate fourth-floor backing note; do not merge with verified third-floor 2-inch note.