Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1067-assemblyverified · printed
sheet_subject
DETAILS OF LOWER STORIES BROADWAY ELEVATIONSelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
third_floor_corner_plan
PLAN AT CORNER 3RD FLOORSelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
second_floor_corner_plan
PLAN AT CORNER 2ND FLOORSelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
first_floor_corner_plan
PLAN AT CORNER 1ST FLOORSelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
first_floor_sash_jamb_section
SECTION THRU JAMB 1ST FL SASHSelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
section_reference
SECTION A-ASelected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
first_floor_finish_line
LINE OF FIN. 1ST FL.Selected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyverified · printed
second_floor_finish_line
LINE OF FIN. 2ND FL.Selected visually read evidence; partial assembly-local extraction.
parallel-img1067-assemblyunreviewed · printed
dimensions_unresolved
[stone courses, sash dimensions, corner chains and section elevations too small to verify]Numeric value unresolved
Uncertain or unreadable detail; value withheld; further review required.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: [stone courses, sash dimensions, corner chains and section elevations too small to verify]
Uncertain or unreadable detail; value withheld; further review required.
parallel-img1067-assemblyverified · printed
first-floor-corner-vault-use
VAULT IN STAMP DEPT.Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: VAULT IN STAMP DEPT.
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyunreviewed · printed
first-floor-corner-concrete-derivation-note
CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE DETAILED ON CORNERS AT A POINT 9'-8" FROM THE INTERSECTION; VOID BEHIND STONE WORK TO BE FILLED WITH BATS [last words require crop]Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: CONCRETE WALLS OF BASEMENT ABOVE GRADE TO BE DETAILED ON CORNERS AT A POINT 9'-8" FROM THE INTERSECTION; VOID BEHIND STONE WORK TO BE FILLED WITH BATS [last words require crop]
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
second-floor-elevation-sash-material
STEEL SASHSource-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: STEEL SASH
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
second-floor-elevation-glazing
PL. GLASSSource-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: PL. GLASS
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
first-floor-section-waterproofing
MEMBRANE WATERPROOFINGSource-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: MEMBRANE WATERPROOFING
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
first-floor-section-flashing
LEAD FLASHING & COUNTER FLASHINGSource-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: LEAD FLASHING & COUNTER FLASHING
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
third-floor-reference-line
LINE OF 3RD FL.Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: LINE OF 3RD FL.
Source-local additive detail evidence only. No installed quantity, room polygon, revision authority or accepted model geometry established.
parallel-img1067-assemblyverified · printed
selected_first_to_second_floor_local_stone_course_height
2′-0″24 in
One repeated local course witness in first-to-second-floor elevation chain, selected beside the mid-height lower stone block. Course/joint convention already verified separately. No installed count or complete course schedule.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: 2′-0″
One repeated local course witness in first-to-second-floor elevation chain, selected beside the mid-height lower stone block. Course/joint convention already verified separately. No installed count or complete course schedule.
parallel-img1067-assemblyillegible · printed
cornice_and_spacer_fractional_dimensions
UnresolvedNumeric value unresolved
Small spacer and first-floor cornice profile fractions not securely read in this bounded crop; neighboring 2′-0″ courses cannot supply them.
parallel-img1067-assemblyverified · printed
first_floor_jamb_stool_alternative_material
MARBLE OR WOOD STOOL AS REQUIREDPrinted material alternatives for stool in first-floor sash jamb section; does not select installed marble/wood, finish, thickness or room applicability.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: MARBLE OR WOOD STOOL AS REQUIRED
Printed material alternatives for stool in first-floor sash jamb section; does not select installed marble/wood, finish, thickness or room applicability.
parallel-img1067-assemblyverified · printed
first_floor_jamb_grille_designation
GRILLELeader identifies grille within jamb-section/window-side zone. No bar size, count, material or installed grille quantity.
parallel-img1067-assemblyverified · printed
first_floor_jamb_to_window_center_local_span
3′-9″45 in
Local horizontal term below section between left jamb-side witness and window center reference. Exact rough/finished face classification and opening width remain open.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: 3′-9″
Local horizontal term below section between left jamb-side witness and window center reference. Exact rough/finished face classification and opening width remain open.
parallel-img1067-assemblyillegible · printed
first_floor_jamb_wainscot_room_clause
WOOD WAINSCOT IN [room text unresolved]WOOD WAINSCOT is readable but room wording and adjacent lower screed instruction are not secure at native crop; preserve entire clause unresolved without room assignment.
IMG_1067 · W-203 · Locate on drawing ↗Drawing notation: WOOD WAINSCOT IN [room text unresolved]
WOOD WAINSCOT is readable but room wording and adjacent lower screed instruction are not secure at native crop; preserve entire clause unresolved without room assignment.