Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
parallel-img1043-typicalverified · printed
paneling_scope
This paneling typical for all counters except Navy. Dividing stiles to center on mullions in rear.Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
IMG_1043 · W-565 · Locate on drawing ↗Drawing notation: This paneling typical for all counters except Navy. Dividing stiles to center on mullions in rear.
Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
parallel-img1043-typicalverified · printed
section_depth
2'-6"30 in
Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
parallel-img1043-typicalverified · printed
plan_depth
30"30 in
Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
parallel-img1043-typicalverified · printed
field_verification
CONTRACTOR MUST VERIFY ALL MEASUREMENTS ON THIS DRAWING AND REPORT ANY INACCURACY TO THE ARCHITECTSelected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
IMG_1043 · W-565 · Locate on drawing ↗Drawing notation: CONTRACTOR MUST VERIFY ALL MEASUREMENTS ON THIS DRAWING AND REPORT ANY INACCURACY TO THE ARCHITECT
Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
parallel-img1043-typicalverified · printed
drawing_scale
3/4" = 1'-0" & F.S.Selected visible source evidence; partial review. Applies only to depicted assembly, not whole-building geometry.
parallel-img1043-typicalverified · printed
typical_section_vertical_overall_witness
3′-6″42 in
Left vertical dimension spans drawn typical section from top profile to base line; source-local42in only, not floor datum.
parallel-img1043-typicalverified · printed
typical_section_upper_vertical_interval
9″9 in
Short right-hand vertical interval at open space immediately below top; endpoint pair is drawn upper compartment, not shelf thickness.
IMG_1043 · W-565 · Locate on drawing ↗Drawing notation: 9″
Short right-hand vertical interval at open space immediately below top; endpoint pair is drawn upper compartment, not shelf thickness.
parallel-img1043-typicalverified · printed
typical_section_room_applicability
TYPICAL SECTION FOR COUNTERS IN ROOMS 620, 616, 615, 505, & 315Literal caption below section; room numbers retained as printed identifiers only. Does not establish installed instances or current room assignments.
IMG_1043 · W-565 · Locate on drawing ↗Drawing notation: TYPICAL SECTION FOR COUNTERS IN ROOMS 620, 616, 615, 505, & 315
Literal caption below section; room numbers retained as printed identifiers only. Does not establish installed instances or current room assignments.