Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_basket_lacing
LACE WITH COPPER WIRE WHEN CLOSEDSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Printed instruction beside unfolded wire-basket diagram.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: LACE WITH COPPER WIRE WHEN CLOSED
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Printed instruction beside unfolded wire-basket diagram.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_basket_mesh
½″ MESH0.5 in
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Mesh aperture designation; no manufactured tolerance.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: ½″ MESH
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Mesh aperture designation; no manufactured tolerance.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_basket_wire_gauge
12 GAUGE COPPER WIRE12 gauge
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Gauge designation only; gauge system and wire diameter not inferred.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: 12 GAUGE COPPER WIRE
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Gauge designation only; gauge system and wire diameter not inferred.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_attachment_medium
SCREW SET IN CEMENTSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader addresses gooseneck attachment screw; screw size unresolved.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: SCREW SET IN CEMENT
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader addresses gooseneck attachment screw; screw size unresolved.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_strap_note_quantity
(3 IN NUMBER)3 count
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Source-note quantity for depicted gooseneck strap assembly; not an installed-building count.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: (3 IN NUMBER)
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Source-note quantity for depicted gooseneck strap assembly; not an installed-building count.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_strap_attachment_relationship
SOLDERED TO LEAD GOOSENECK AND SCREWED TO CONCRETE TO CARRY WEIGHT OF GOOSENECKSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Strap-width glyph not adopted. Load-support relationship is printed, not a capacity calculation.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: SOLDERED TO LEAD GOOSENECK AND SCREWED TO CONCRETE TO CARRY WEIGHT OF GOOSENECK
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Strap-width glyph not adopted. Load-support relationship is printed, not a capacity calculation.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_gooseneck_material
LEAD GOOSENECKSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Material from the strap clause; no thickness or pipe dimension established.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: LEAD GOOSENECK
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Material from the strap clause; no thickness or pipe dimension established.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_thimble_material
COPPER THIMBLESource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader at lower pipe sleeve.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: COPPER THIMBLE
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader at lower pipe sleeve.
metalenv1014t-img1083-roof-outletverified · printed
roof_outlet_assignment
FOR MAIN ROOFSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Title scope only; physical outlet instances remain unregistered.
IMG_1083 · W-212 · Locate on drawing ↗Drawing notation: FOR MAIN ROOF
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Title scope only; physical outlet instances remain unregistered.