Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
main-north-center-exterior-framed-assemblyunreviewed · derived
parent bay center canonical X
COLUMN NO. 90 / COLUMN NO. 91; 14'-0" module0 ft
accepted-grid-center-only. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: COLUMN NO. 90 / COLUMN NO. 91; 14'-0" module
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. This is the center of the structural bay, not a verified frame jamb or centroid.
Calculated from: column-90-registered-world-x, column-91-registered-world-x, main-entrance-img1073-bay-spacing
main-north-center-exterior-framed-assemblyverified · printed
nominal framed assembly width in plan
7'-6"7.5 ft
verified-prior-registration. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: 7'-6"
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. Horizontal frame width, not frame height, rough wall opening or clear passage.
Calculated from: main-entrance-img1073-door-frame-width
main-north-center-exterior-framed-assemblyunreviewed · derived
conditional west/positive-X outer frame limit if exactly centered on bay
0 + (7'-6" / 2)3.75 ft
diagnostic-not-accepted. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: 0 + (7'-6" / 2)
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. The printed plan and provisional W3 trace do not independently verify a finished frame edge at this exact station.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: 0 + (7'-6" / 2)
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace. The printed plan and provisional W3 trace do not independently verify a finished frame edge at this exact station.
Calculated from: center-frame-bay-center-x, center-frame-plan-width
main-north-center-exterior-framed-assemblyunreviewed · derived
conditional east/negative-X outer frame limit if exactly centered on bay
0 - (7'-6" / 2)-3.75 ft
diagnostic-not-accepted. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: 0 - (7'-6" / 2)
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. Not a verified finished jamb, rough opening or wall-cut edge.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: 0 - (7'-6" / 2)
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace. Not a verified finished jamb, rough opening or wall-cut edge.
Calculated from: center-frame-bay-center-x, center-frame-plan-width
main-north-center-exterior-framed-assemblyunreviewed · inferred
W3 traced door-line center canonical Z
Unresolved75.577 ft
unreviewed-preview-only. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Main exterior center door group; door group with swing arcs
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace. 1.25-foot W3 registration uncertainty; line class and frame front/back faces unclassified.
Calculated from: main-entrance-center-door-plane-world-z
main-north-center-exterior-framed-assemblyunreviewed · inferred
accepted exterior finished frame/host face canonical Z
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Main exterior center door group; door group with swing arcs
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved.
main-north-center-exterior-framed-assemblyunreviewed · inferred
accepted foyer-side finished frame/host face canonical Z
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Main exterior center door group; door group with swing arcs
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved.
main-north-center-exterior-framed-assemblyunreviewed · inferred
physical frame front-to-back depth or section thickness
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. Small plan chains exist but their endpoints cannot yet be mapped to frame front/back faces.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved. Small plan chains exist but their endpoints cannot yet be mapped to frame front/back faces.
main-north-center-exterior-framed-assemblyunreviewed · inferred
physical host-wall thickness across opening
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved.
IMG_1202 · sheet-W3 · Locate on drawing ↗Drawing notation: Main exterior center door group; door group with swing arcs
+X west/page-right and +Z north/page-down under the provisional W3 transform; provisional-unreviewed-plan-trace.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved.
main-north-center-exterior-framed-assemblyunreviewed · printed
adjacent upper exterior landing elevation, historical datum
ELEV. 93.2493.24 historic-datum ft
previously-reviewed-context-only. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1242 · sheet-W201 · Locate on drawing ↗Drawing notation: ELEV. 93.24
local entrance stair section; historical elevation datum; previously-reviewed-exterior-landing-datum. Not established as threshold top, frame bottom or foyer floor.
main-north-center-exterior-framed-assemblyunreviewed · printed
first-floor finish elevation, historical datum
FIRST FLOOR 93.2593.25 historic-datum ft
previously-verified-context-only. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
main-north-center-exterior-framed-assemblyunreviewed · observed
Main Street entrance threshold material/type label
METAL THRESHOLDtargeted-reviewed-categorical-only. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved. W218 shows the Main Street door threshold type; its exact top, bottom, front/back and continuity across all three bays are not measured here.
main-north-center-exterior-framed-assemblyunreviewed · inferred
accepted threshold top canonical Y
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved. Neither 93.24 nor 93.25 can be substituted for this contact elevation without a checked section.
IMG_1242 · sheet-W201 · Locate on drawing ↗Drawing notation: ELEV. 93.24
local entrance stair section; historical elevation datum; previously-reviewed-exterior-landing-datum. Neither 93.24 nor 93.25 can be substituted for this contact elevation without a checked section.
IMG_1314 · sheet-W400 · Locate on drawing ↗Drawing notation: FIRST FLOOR 93.25
historical elevation datum; previously-verified-floor-datum. Neither 93.24 nor 93.25 can be substituted for this contact elevation without a checked section.
main-north-center-exterior-framed-assemblyunreviewed · inferred
accepted threshold underside canonical Y
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved.
main-north-center-exterior-framed-assemblyunreviewed · inferred
accepted frame head canonical Y
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. Foyer ceiling height and small elevation component dimensions do not establish the assembly head.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PART ELEVATION OF FOYER SIDE OF MAIN ST. ENTRANCE DOORS
upright foyer-side elevation; no scale inferred from raster; targeted-identity-and-material-review; dimension endpoints not accepted. Foyer ceiling height and small elevation component dimensions do not establish the assembly head.
main-north-center-exterior-framed-assemblyunreviewed · inferred
host-wall rough opening width
UnresolvedNumeric value unresolved
unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: MAIN ENTRANCE DETAIL; MAIN STREET ELEVATION; PLAN; COLUMN NO. 90; COLUMN NO. 91; 14'-0"; 7'-6"; 6'-0"; BRONZE
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. The printed 7-foot-6-inch frame width is not recast as rough opening width.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: PLAN AT MAIN ST. DOORS; METAL THRESHOLD
upright Main Street exterior door plan; page directions not used as canonical stations; targeted-identity-and-threshold-label-review; depth-chain-endpoints-unresolved. The printed 7-foot-6-inch frame width is not recast as rough opening width.
main-north-center-exterior-framed-assemblyunreviewed · observed
bronze/glass panel and frame section build-up
BRONZE; glass fields shown on W218 foyer-side elevationNumeric value unresolved
geometry-unresolved. Printed bay control and provisional W3 line do not complete frame XYZ extents or host.
IMG_1073 · sheet-IMG1073-main-entrance-detail · Locate on drawing ↗Drawing notation: BRONZE; glass fields shown on W218 foyer-side elevation
upright; elevation above plan; page-left/page-right are not world east/west; targeted-reviewed-for-assembly-identity-and-prior-plan-widths; elevation-head-and-jamb-depth-unresolved. Glazing thickness, profiles, attachments and full transom/head limits remain null.
IMG_1099 · sheet-W218 · Locate on drawing ↗Drawing notation: BRONZE; glass fields shown on W218 foyer-side elevation
upright foyer-side elevation; no scale inferred from raster; targeted-identity-and-material-review; dimension endpoints not accepted. Glazing thickness, profiles, attachments and full transom/head limits remain null.