Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
lightspec1013e-img1292-general-specificationverified · printed
fixture_stud_field_verification
SIZE MUST BE VERIFIED AND FIXTURES MADE TO SUITIMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Installation compatibility/field verification requirement preserved; no as-built stud accepted.
IMG_1292 · Locate on drawing ↗Drawing notation: SIZE MUST BE VERIFIED AND FIXTURES MADE TO SUIT
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Installation compatibility/field verification requirement preserved; no as-built stud accepted.
lightspec1013e-img1292-general-specificationillegible · printed
existing_building_fixture_stud_size
IN OLD BUILDINGS ... GENERALLY [fraction] IN.Numeric value unresolved
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Specific original stud fraction not secure.
IMG_1292 · Locate on drawing ↗Drawing notation: IN OLD BUILDINGS ... GENERALLY [fraction] IN.
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Specific original stud fraction not secure.
lightspec1013e-img1292-general-specificationillegible · printed
new_building_fixture_stud_option_1
NEW BUILDINGS MAY HAVE [fraction] OR [fraction] STUDSNumeric value unresolved
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. First listed stud option fraction unestablished.
IMG_1292 · Locate on drawing ↗Drawing notation: NEW BUILDINGS MAY HAVE [fraction] OR [fraction] STUDS
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. First listed stud option fraction unestablished.
lightspec1013e-img1292-general-specificationillegible · printed
new_building_fixture_stud_option_2
NEW BUILDINGS MAY HAVE [fraction] OR [fraction] STUDSNumeric value unresolved
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Second listed stud option fraction unestablished.
IMG_1292 · Locate on drawing ↗Drawing notation: NEW BUILDINGS MAY HAVE [fraction] OR [fraction] STUDS
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Second listed stud option fraction unestablished.
lightspec1013e-img1292-general-specificationverified · printed
lamp_filament_globe_relationship
LOCATE SOCKETS OR RECEPTACLES SO LAMP FILAMENT IS IN CENTER OF BALL GLOBES AND ACORN GLOBESIMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Component center alignment, not a room/world station.
IMG_1292 · Locate on drawing ↗Drawing notation: LOCATE SOCKETS OR RECEPTACLES SO LAMP FILAMENT IS IN CENTER OF BALL GLOBES AND ACORN GLOBES
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Component center alignment, not a room/world station.
lightspec1013e-img1292-general-specificationverified · printed
ball_acorn_globe_type_reference
THEY SHALL BE AS SHOWN FOR TYPE B AND TYPE C GLOBESIMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. This general-note C reference remains as printed separately from the glassware paragraph header G; it does not relabel that paragraph.
IMG_1292 · Locate on drawing ↗Drawing notation: THEY SHALL BE AS SHOWN FOR TYPE B AND TYPE C GLOBES
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. This general-note C reference remains as printed separately from the glassware paragraph header G; it does not relabel that paragraph.
lightspec1013e-img1292-general-specificationverified · printed
pendant_switch_arm_reinforcement
REINFORCING PIECE FOR PENDENT SWITCH ARMS SHALL BE SOLDERED IN PLACEIMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption.
IMG_1292 · Locate on drawing ↗Drawing notation: REINFORCING PIECE FOR PENDENT SWITCH ARMS SHALL BE SOLDERED IN PLACE
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption.
lightspec1013e-img1292-general-specificationverified · printed
finish_default
ALL FINISH SHALL BE LIGHT OXIDIZED BRASS UNLESS OTHERWISE NOTEDIMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Default miscellaneous-sheet finish; preserve explicit flat-washable-cream424 exception and separate bronze P-type sheet finishes.
IMG_1292 · Locate on drawing ↗Drawing notation: ALL FINISH SHALL BE LIGHT OXIDIZED BRASS UNLESS OTHERWISE NOTED
IMG1292 general-notes requirement for the illustrated miscellaneous fixture family only, subject to its printed exceptions; no building-wide material or installation assumption. Default miscellaneous-sheet finish; preserve explicit flat-washable-cream424 exception and separate bronze P-type sheet finishes.
lightspec1013e-img1292-general-specificationunreviewed · printed
arm_tubing_process_remains_unestablished
[No independently legible arm-tubing process clause in the inspected GENERAL NOTES]The candidate ALL TUBING USED FOR ARMS wording cannot be located securely in the inspected top general-note block. Exposed-parts brass and adjacent canopy/ring clauses do not establish arm manufacturing process.
IMG_1292 · Locate on drawing ↗Drawing notation: [No independently legible arm-tubing process clause in the inspected GENERAL NOTES]
The candidate ALL TUBING USED FOR ARMS wording cannot be located securely in the inspected top general-note block. Exposed-parts brass and adjacent canopy/ring clauses do not establish arm manufacturing process.
Calculated from: lightspec1013e-img1292-024-arm_tubing_construction, lightfine1013n-img_1292-012-arm_tubing_process_still_unestablished
lightspec1013e-img1292-general-specificationunreviewed · printed
socket_nipple_material_remains_unestablished
ALL BRASS SHELL SOCKETS SHALL HAVE AMPLE MEANS FOR HOLDING CAP TO SHELL [nipple-material clause not established]Same socket block reads cap-retention AMPLE MEANS. This is not a nipple material specification; retain original null question without claiming a material.
IMG_1292 · Locate on drawing ↗Drawing notation: ALL BRASS SHELL SOCKETS SHALL HAVE AMPLE MEANS FOR HOLDING CAP TO SHELL [nipple-material clause not established]
Same socket block reads cap-retention AMPLE MEANS. This is not a nipple material specification; retain original null question without claiming a material.
Calculated from: lightspec1013e-img1292-035-socket_nipple_material
lightspec1013e-img1292-general-specificationverified · printed
finish_plating_clause_exact_wording
ALL FINISH SHALL BE PRODUCED BY ELECTRO PLATING UNLESS OTHERWISE NOTEDSame original general FINISH heading and immediately following clause. Printed exception preserved; no installed coating or broader intermediate-process closure asserted.
IMG_1292 · Locate on drawing ↗Drawing notation: ALL FINISH SHALL BE PRODUCED BY ELECTRO PLATING UNLESS OTHERWISE NOTED
Same original general FINISH heading and immediately following clause. Printed exception preserved; no installed coating or broader intermediate-process closure asserted.
lightspec1013e-img1292-general-specificationillegible · printed
finish_intermediate_process_remains_partial
[Dark-color intermediate operation wording remains partly blurred]Yellow-brass polishing and dark-color recess retention already have verified prior records. Exact intervening operation/grain wording remains insecure in this crop and is not reconstructed from expected fabrication practice.
IMG_1292 · Locate on drawing ↗Drawing notation: [Dark-color intermediate operation wording remains partly blurred]
Yellow-brass polishing and dark-color recess retention already have verified prior records. Exact intervening operation/grain wording remains insecure in this crop and is not reconstructed from expected fabrication practice.
Calculated from: lightspec1013e-img1292-040-finish_substrate_process_remaining