Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
library-607-wall-elevation-registration-gateverified · observed
Placed millwork analytical geometry gate
FAIL — topological wall identities only; zero shared metric controlsThe wall names may be linked to the corresponding cardinal Room 607 plan edges as topological metadata. No millwork line, panel, shelf, door, moulding or track may be positioned on those edges yet.
library-607-wall-elevation-registration-gateverified · derived
Topologically correlated cardinal wall identities
4 cardinal walls4 count
Calculated from: library-607-wall-elevation-count
library-607-wall-elevation-registration-gateverified · observed
Shared like-for-like metric controls
00 count
Cardinal wall labels establish semantic correspondence only. The millwork elevations have no classified total-width endpoints, source-space control coordinates, accepted horizontal handedness, or opening instance tied to a plan opening.
library-607-wall-elevation-registration-gateunreviewed · derived
north plan trace diagnostic length
45.173393 ft provisional trace45.173393 ft
calculated from provisional traced endpoints; accepted finish-face length remains null.
library-607-wall-elevation-registration-gateunreviewed · derived
south plan trace diagnostic length
44.621335 ft provisional trace44.621335 ft
calculated from provisional traced endpoints; accepted finish-face length remains null.
library-607-wall-elevation-registration-gateunreviewed · derived
east plan trace diagnostic length
21.638373 ft provisional trace21.638373 ft
calculated from provisional traced endpoints; accepted finish-face length remains null.
library-607-wall-elevation-registration-gateunreviewed · derived
west plan trace diagnostic length
22.735201 ft provisional trace22.735201 ft
calculated from provisional traced endpoints; accepted finish-face length remains null.
library-607-wall-elevation-registration-gateunreviewed · derived
North door candidate traced width
3.213921 ft provisional trace3.213921 ft
The plan traces one Room 607 north-wall door, but the first millwork audit does not assign any drawn door/open section to that same instance or classify its endpoints.
library-607-wall-elevation-registration-gateunreviewed · observed
Accepted millwork-elevation to Room 607 plan transform
UnresolvedCardinal wall labels establish semantic correspondence only. The millwork elevations have no classified total-width endpoints, source-space control coordinates, accepted horizontal handedness, or opening instance tied to a plan opening.
library-607-wall-elevation-registration-gateverified · observed
Accepted placed millwork geometry
NoneZero shared metric controls connect the millwork elevations to the plan trace.; Room 607 plan boundaries are provisional coarse traces with 3.25-foot conservative uncertainty, not accepted finish faces.; All current exact millwork dimensions lack classified extension-line endpoints.; Horizontal handedness and local origins of the four elevation views are unresolved.; The one traced north-wall plan door has no matched millwork-elevation opening instance.; Vertical baseline, ceiling/millwork top datum and overall wall heights are not accepted.; The drawing explicitly directs the contractor to verify all measurements and conditions on the job.