Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
legacy-img1080-assemblyverified · printed
finial-view
TOP VIEW OF FINIALSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: TOP VIEW OF FINIAL
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1080-assemblyverified · printed
head-ceiling
PLASTER CORNICE / METAL LATH & PL.Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: PLASTER CORNICE / METAL LATH & PL.
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1080-assemblyverified · printed
datum-reference-note
DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONE AND INCLUDE ALL JOINTSSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: DIMENSIONS GIVEN ARE FROM BOTTOM OF STONE TO BOTTOM OF STONE AND INCLUDE ALL JOINTS
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1080-assemblyunreviewed · printed
library-head-wood-fascia
[dotted-line wood fascia note; exact wording unresolved]Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: [dotted-line wood fascia note; exact wording unresolved]
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1080-assemblyverified · printed
library-head-reinforcement-companion-sheet
SEE STRUCTURAL DESIGN SH. #415 FOR SIZE & SPACING OF REINFORCING415 sheet-number
Additional sheet number in previously closed structural note; library head only. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: SEE STRUCTURAL DESIGN SH. #415 FOR SIZE & SPACING OF REINFORCING
Additional sheet number in previously closed structural note; library head only. Source-local detail/type only; no installed quantity or physical placement.
Calculated from: metal1012h-img1080-structural-reference
legacy-img1080-assemblyverified · printed
cornice-section-dotted-stone-interpretation
DOTTED LINES SHOW STONE BEYOND LINTELDotted geometry denotes out-of-section stone. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: DOTTED LINES SHOW STONE BEYOND LINTEL
Dotted geometry denotes out-of-section stone. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1080-assemblyverified · printed
cornice-section-selected-stone-band-width
1′-4″16 in
Local horizontal band through stone in tall section; not whole wall thickness. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: 1′-4″
Local horizontal band through stone in tall section; not whole wall thickness. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1080-assemblyverified · printed
seventh-floor-toilet-base-finish
TILE FL. & BASE IN TOILET RMSConditional seventh-floor toilet finish note; no room-instance mapping. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: TILE FL. & BASE IN TOILET RMS
Conditional seventh-floor toilet finish note; no room-instance mapping. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1080-assemblyverified · printed
private-toilet-visiting-judges-room-selected-height
10′-3″ FOR PRIVATE TOILETS AND VISITING JUDGES ROOM123 in
Alternative vertical height labelled for these rooms, distinct from adjacent joint-course chain; exact floor/ceiling endpoint faces need audit. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: 10′-3″ FOR PRIVATE TOILETS AND VISITING JUDGES ROOM
Alternative vertical height labelled for these rooms, distinct from adjacent joint-course chain; exact floor/ceiling endpoint faces need audit. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1080-assemblyunreviewed · printed
library-head-wood-note-unresolved
WOOD [remainder obscured/unclear]Wood callout visible at library head; exact trim name and dimension unresolved. Source-local detail/type only; no installed quantity or physical placement.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: WOOD [remainder obscured/unclear]
Wood callout visible at library head; exact trim name and dimension unresolved. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1080-assemblyverified · printed
library-head-selected-drop
3′-0″36 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Vertical extension from FIN. 7th floor datum to lower library-head finish/cornice zone; no total window height.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: 3′-0″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Vertical extension from FIN. 7th floor datum to lower library-head finish/cornice zone; no total window height.
legacy-img1080-assemblyverified · printed
sheet_number
W209209 drawing-number
Selected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyverified · printed
facade_title
DETAIL OF UPPER STORIES BROADWAY ELEVATIONSelected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyverified · printed
library_head_section
SECTION THRU LIBRARY WINDOW HEADSelected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyverified · printed
floor_datum_7
LINE OF FIN. 7TH FL.Selected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyverified · printed
floor_datum_6
LINE OF FIN. 6TH FL.Selected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyverified · printed
column_centerline
CENTER LINE OF COLUMNSelected printed source or documented prior audit; partial source-local review.
legacy-img1080-assemblyunreviewed · printed
remaining_material_dimensions_unresolved
[upper-floor and library head section layer notes/dimensions]Numeric value unresolved
Tentative or unresolved locator; numeric value withheld.
legacy-img1080-assemblyverified · printed
upper_cornice_counterflashing_material
LEAD COUNTER-FLASHINGSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper roof/parapet return leader.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: LEAD COUNTER-FLASHING
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper roof/parapet return leader.
legacy-img1080-assemblyverified · printed
upper_cornice_dampproofing_requirement
DAMP PROOFINGSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader addresses vertical layer behind outer stone; composition/thickness not established.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: DAMP PROOFING
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Leader addresses vertical layer behind outer stone; composition/thickness not established.
legacy-img1080-assemblyverified · printed
upper_cornice_reglet
REGLETSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper counterflashing return; no groove dimensions.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: REGLET
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper counterflashing return; no groove dimensions.
legacy-img1080-assemblyverified · printed
upper_cornice_roof_construction
BUILT-UP ROOFSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper roof surface leader; ply count and thickness unresolved.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: BUILT-UP ROOF
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Upper roof surface leader; ply count and thickness unresolved.
legacy-img1080-assemblyverified · printed
upper_cornice_roof_insulation
INSULATIONSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Separate note below roof-surface wording; insulation type and thickness unresolved.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: INSULATION
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Separate note below roof-surface wording; insulation type and thickness unresolved.
legacy-img1080-assemblyverified · printed
lower_cornice_flashing_material
LEAD FLASHINGSource-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Lower cornice flashing leader, separate from upper counterflashing.
IMG_1080 · W-209 · Locate on drawing ↗Drawing notation: LEAD FLASHING
Source-local printed witness only; no accepted physical geometry, installed quantity or source-issue selection. Lower cornice flashing leader, separate from upper counterflashing.