Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
legacy-img1079-assemblyverified · printed
coping-material
TERRA COTTA COPINGSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: TERRA COTTA COPING
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1079-assemblyverified · printed
roof-flashing
COPPER FLASHINGSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: COPPER FLASHING
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1079-assemblyverified · printed
light-court-parapet-finish
CEMENT FINISHSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: CEMENT FINISH
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1079-assemblyunreviewed · printed
section-column-reading-conflict
SECTION BETWEEN COLUMNS 16-30 21-33Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: SECTION BETWEEN COLUMNS 16-30 21-33
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1079-assemblyverified · printed
steel-window-applicability
TYPICAL FOR STEEL WINDOWS IN EAST AND WEST WALLS OF LIGHT COURTSource-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: TYPICAL FOR STEEL WINDOWS IN EAST AND WEST WALLS OF LIGHT COURT
Source-local additive detail review; no installed quantity, accepted room geometry, physical placement or wall cuts established.
legacy-img1079-assemblyverified · printed
left_upper_light_court_masonry_course_count
22 COURSES LESS ONE JOINT22 course-count
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct left upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct left upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
legacy-img1079-assemblyillegible · printed
left_upper_light_court_masonry_course_span
22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]Numeric value unresolved
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
legacy-img1079-assemblyverified · printed
middle_upper_light_court_masonry_course_count
22 COURSES LESS ONE JOINT22 course-count
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct middle upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct middle upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
legacy-img1079-assemblyillegible · printed
middle_upper_light_court_masonry_course_span
22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]Numeric value unresolved
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
legacy-img1079-assemblyverified · printed
right_upper_light_court_masonry_course_count
22 COURSES LESS ONE JOINT22 course-count
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct right upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Distinct right upper light-court section module; retains ONE JOINT subtraction literally. Source module count, not installed building quantity.
legacy-img1079-assemblyillegible · printed
right_upper_light_court_masonry_course_span
22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]Numeric value unresolved
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 22 COURSES LESS ONE JOINT = 5′-2…″ [fraction not adopted]
Printed source-local upper light-court course group. Foot/inch marks are visible but fractional suffix is withheld; no course or joint thickness calculated.
legacy-img1079-assemblyverified · printed
right_upper_section_louver_material
COPPER LOUVERSPrinted source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Right upper light-court section louver leader.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: COPPER LOUVERS
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Right upper light-court section louver leader.
legacy-img1079-assemblyverified · printed
right_upper_section_screen_relationship
WITH SCREEN BEHINDPrinted source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Screen-behind-louvers relationship only; mesh/material/attachment dimensions unresolved.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: WITH SCREEN BEHIND
Printed source-local witness only; not installed quantity, actual member profile, outside diameter or accepted physical geometry. Screen-behind-louvers relationship only; mesh/material/attachment dimensions unresolved.
legacy-img1079-assemblyverified · printed
light-court-upper-leader-material
COPPER LEADERUpper right light court wall section. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-upper-leader-drip-material
WITH NICKEL DRIPSLeader accessory only. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-reinforcement-companion-sheet
FOR SIZE & SPACING OF REINFORCING SEE STRUCTURAL DESIGN SHEET #419419 sheet-number
Upper right light court section reinforcement reference. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: FOR SIZE & SPACING OF REINFORCING SEE STRUCTURAL DESIGN SHEET #419
Upper right light court section reinforcement reference. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-left-wall-facing-material
FACE BRICKLeft light court section; no street-facing material transfer. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: FACE BRICK
Left light court section; no street-facing material transfer. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-left-lower-window-material
WOOD SASH & FRAMESLower-left light court section; reconciles drawn wood option with sheet's separate steel-window applicability. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: WOOD SASH & FRAMES
Lower-left light court section; reconciles drawn wood option with sheet's separate steel-window applicability. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-radiator-location-condition
DOTTED LINES INDICATE RADIATORS IN 3RD 4TH & 5TH FLOORSConditional equipment location, not measured radiator size or quantities. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: DOTTED LINES INDICATE RADIATORS IN 3RD 4TH & 5TH FLOORS
Conditional equipment location, not measured radiator size or quantities. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-between-columns-16-20-finish
PLASTER CORNICEBetween-columns 16–20 section; distinct from 16–30 / 21–33. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: PLASTER CORNICE
Between-columns 16–20 section; distinct from 16–30 / 21–33. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-high-roof-datum-notation
H.P. ROOF ELEV. 195.42Original numeric datum kept as notation; unit/benchmark not explicitly established here. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: H.P. ROOF ELEV. 195.42
Original numeric datum kept as notation; unit/benchmark not explicitly established here. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
light-court-low-roof-datum-notation
LOW POINT OF ROOF ELEV. 194.68Distinct high/low roof annotations; no arbitrary datum transform. Source-local detail/type only; no installed quantity or physical placement.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: LOW POINT OF ROOF ELEV. 194.68
Distinct high/low roof annotations; no arbitrary datum transform. Source-local detail/type only; no installed quantity or physical placement.
legacy-img1079-assemblyverified · printed
left-upper-masonry-courses
19 COURSES19 course-count
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Source-local masonry module count; not an installed building quantity.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 19 COURSES
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Source-local masonry module count; not an installed building quantity.
legacy-img1079-assemblyverified · printed
left-upper-masonry-course-span
19 COURSES 4′-3½″51.5 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Left light-court section vertical witness from sill line to next slab/finish level.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 19 COURSES 4′-3½″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Left light-court section vertical witness from sill line to next slab/finish level.
legacy-img1079-assemblyverified · printed
right-lower-module-course-count
12 COURSES LESS ONE JOINT12 course-count
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Count in right 16–20 section module, with joint subtraction retained literally.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 12 COURSES LESS ONE JOINT
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Count in right 16–20 section module, with joint subtraction retained literally.
legacy-img1079-assemblyverified · printed
right-lower-module-course-span
12 COURSES LESS ONE JOINT = 2′-8½″32.5 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section slab/beam-to-lower-head module. No course/joint thickness calculated.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 12 COURSES LESS ONE JOINT = 2′-8½″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section slab/beam-to-lower-head module. No course/joint thickness calculated.
legacy-img1079-assemblyverified · printed
left-second-floor-course-count
16 COURSES16 course-count
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate lower second-floor masonry module.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 16 COURSES
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate lower second-floor masonry module.
legacy-img1079-assemblyverified · printed
left-second-floor-course-span
16 COURSES 3′-7¼″43.25 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Lower left course module from upper sill to second-floor line; separate from upper module.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 16 COURSES 3′-7¼″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Lower left course module from upper sill to second-floor line; separate from upper module.
legacy-img1079-assemblyverified · printed
right-section-inner-drop
3′-1″37 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section vertical extension from finished seventh-floor datum toward the beam zone; endpoint not a whole-room clear height.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 3′-1″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Right 16–20 section vertical extension from finished seventh-floor datum toward the beam zone; endpoint not a whole-room clear height.
legacy-img1079-assemblyverified · printed
right-section-ceiling-drop
4′-8″56 in
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate right 16–20 finished-floor-to-plaster-cornice control.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: 4′-8″
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Separate right 16–20 finished-floor-to-plaster-cornice control.
legacy-img1079-assemblyverified · printed
left-dampproofing-note
DAMPPROOFINGPrinted source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed left wall leader; distinct from membrane waterproofing and lead flashing.
IMG_1079 · W-208 · Locate on drawing ↗Drawing notation: DAMPPROOFING
Printed source-local type/component or section control only; no accepted physical geometry, installed quantity or world registration. Original layer retained separately from revisions. Printed left wall leader; distinct from membrane waterproofing and lead flashing.
legacy-img1079-assemblyverified · printed
sheet_number
W208208 drawing-number
Selected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · printed
cornice_view
SOFFIT OF MAIN CORNICESelected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · printed
facade_title
DETAIL OF UPPER STORIES BROADWAY ELEVATIONSelected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · printed
section_scope
SECTIONS THRU LIGHT COURT WALLSSelected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · printed
section_column_pair
SECTION BETWEEN COLUMNS 16-20Selected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · printed
section_column_pairs_upper
SECTION BETWEEN COLUMNS 16-36 21-33Selected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyverified · observed
wall_chain_limitation
Named right-side sections concern light court walls, not street wall thicknessSelected printed source or documented prior audit; partial source-local review.
IMG_1079 · W208 · Locate on drawing ↗Drawing notation: Named right-side sections concern light court walls, not street wall thickness
Selected printed source or documented prior audit; partial source-local review.
legacy-img1079-assemblyunreviewed · printed
remaining_material_dimensions_unresolved
[floor heights, layer/material codes and dimension endpoints too small]Numeric value unresolved
Tentative or unresolved locator; numeric value withheld.