Printed values, calculations, image traces and observed counts are different kinds of evidence. “Verified” applies to the specific reading—not to the whole room or model.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_left_edge_band_width
5½″5.5 in
Left horizontal plan strip witness before first pen-tray field. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 5½″
Left horizontal plan strip witness before first pen-tray field. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_left_pen_tray_field_horizontal_control
2′-3¾″27.75 in
First horizontal worktop field witness bounded by the left edge band and central band. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 2′-3¾″
First horizontal worktop field witness bounded by the left edge band and central band. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_middle_band_width
5½″5.5 in
Central horizontal plan strip between the two pen-tray fields. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 5½″
Central horizontal plan strip between the two pen-tray fields. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_right_pen_tray_field_horizontal_control
2′-3¾″27.75 in
Second horizontal worktop field witness between central and right edge bands. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 2′-3¾″
Second horizontal worktop field witness between central and right edge bands. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_right_edge_band_width
5½″5.5 in
Right horizontal plan edge-band witness. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 5½″
Right horizontal plan edge-band witness. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_rear_band_depth
5½″5.5 in
Upper short vertical plan strip adjoining pen-tray zone. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 5½″
Upper short vertical plan strip adjoining pen-tray zone. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_main_worktop_field_depth
1′-9″21 in
Middle vertical plan field between upper and lower plan strips. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 1′-9″
Middle vertical plan field between upper and lower plan strips. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_plan_front_band_depth
5½″5.5 in
Lower short vertical plan strip beyond main worktop field. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: 5½″
Lower short vertical plan strip beyond main worktop field. Source-local composite plan band/field; not solid plank thickness or finished tray clear interior. All physical profiles and joinery remain open.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_worktop_main_field_covering
PANTASOTELeader points to large central worktop field in PLAN OF TOP CLERK'S DESK. Printed product/material name only; composition, gauge, color and installed sample remain unresolved.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: PANTASOTE
Leader points to large central worktop field in PLAN OF TOP CLERK'S DESK. Printed product/material name only; composition, gauge, color and installed sample remain unresolved.
joinery1013s-w238-clerk-worktop-typeverified · observed
depicted_clerk_left_pedestal_drawer_front_count
Four drawer fronts depicted4 count
Observed left pedestal in clerk rear elevation. Design-view component count only, not installed desk quantity or drawer interior dimensions.
IMG_1169 · W-238 · Locate on drawing ↗Drawing notation: Four drawer fronts depicted
Observed left pedestal in clerk rear elevation. Design-view component count only, not installed desk quantity or drawer interior dimensions.
joinery1013s-w238-clerk-worktop-typeverified · printed
clerk_under_worktop_slide_feature
SLIDESCurved leaders under worktop in rear elevation designate slides. Travel, section, hardware and installed counts unresolved.